scholarly journals Feasibility of SAPIEN 3 20-mm Transcatheter Heart Valve Implantation in Aortic Stenosis Patients with a Small Aortic Annulus

2021 ◽  
Vol 3 (1) ◽  
pp. 7-13
Author(s):  
Kayo Sugiyama ◽  
Kentaro Mukai ◽  
Atsushi Watanabe ◽  
Mayu Suzuki ◽  
Tetsuya Amano ◽  
...  
2019 ◽  
Vol 14 (13) ◽  
pp. 1378-1385 ◽  
Author(s):  
Sebastien Hascoet ◽  
Robert Dalla Pozza ◽  
Jamie Bentham ◽  
Ronald Giacomo Carere ◽  
Majed Kanaan ◽  
...  

2010 ◽  
Vol 11 (10) ◽  
pp. 727-732 ◽  
Author(s):  
Francesco Saia ◽  
Cinzia Marrozzini ◽  
Gianni DallʼAra ◽  
Vincenzo Russo ◽  
Sofia Martìn-Suàrez ◽  
...  

2018 ◽  
Vol 21 (5) ◽  
pp. E341-E344
Author(s):  
Kentaro Meguro ◽  
Ryota Kakizaki ◽  
Takuya Hashimoto ◽  
Tomoyoshi Yanagisawa ◽  
Toshimi Koitabashi ◽  
...  

Background: Transcatheter aortic valve implantation (TAVI) is effective in treating severe aortic stenosis in inoperable or high-risk surgical patients, however, the little is known about outcomes after Sapien 3 20 mm transcatheter heart valve (THV) implantation. The purpose of this study was to investigate the short term outcomes of Sapien 3 20 mm THV implantation in Japanese people with a small body size. Methods: We retrospectively collected the hospital records of consecutive patients who underwent TAVI using the Sapien 3 20 mm THV between October 2016 and March 2017. Clinical and echocardiographic data from before and one week after TAVI were collected. Results: Six Japanese patients (all female, mean age 89 ± 5 years, body surface area [BSA] 1.29 ± 0.16m2) received a Sapien 3 20 mm THV. All the procedures were feasible and successful, and the 30-day mortality rate was 0%. The functional class and the echocardiographic findings significantly improved (aortic valve area, 0.5 ± 0.1 cm2 to 0.8 ± 0.1cm2; mean pressure gradient, 55 ± 15 mmHg to 19 ± 7 mmHg; P = .043, respectively). However, the values of the indexed effective orifice area in all patients after Sapien 3 20 mm THV implantation were less than 0.85 cm2/m2, suggesting prosthesis-patient mismatch (PPM). Conclusions: The implantation of a Sapien 3 20 mm THV was safe and effective in high surgical risk elderly Japanese patients with a small body size. PPM after Sapien 3 20mm THV may be prevalent among Asians with small body sizes. Careful clinical follow-up will be necessary after Sapien 3 20 mm THV implantation.


2017 ◽  
Vol 33 (4) ◽  
pp. 555.e13-555.e15
Author(s):  
Ayoub El Hammiri ◽  
Jeannot Potvin ◽  
Jean-François Gobeil ◽  
Nicolas Noiseux ◽  
Louis-Mathieu Stevens ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document