scholarly journals A Case Report of the Endovascular Treatment of Mycotic Abdominal Aortic Pseudoaneurysms Using a Customized Stent-Graft

2011 ◽  
Vol 65 (3) ◽  
pp. 241 ◽  
Author(s):  
Seo In Jeong ◽  
Hye Doo Jung ◽  
Jae Hoon Lim ◽  
Nam Yeol Yim ◽  
Nam Kyu Chang ◽  
...  
2005 ◽  
Vol 52 (2) ◽  
pp. 107
Author(s):  
Jeong Yeol Choi ◽  
Dong Hyun Kim ◽  
Hyung Woo Oh ◽  
Jeong Hwan Jang ◽  
Jae Hee Oh ◽  
...  

2019 ◽  
Vol 26 (2) ◽  
pp. 245-249 ◽  
Author(s):  
Andrés Reyes Valdivia ◽  
Francisco Álvarez Marcos ◽  
África Duque Santos ◽  
Julia Ocaña Guaita ◽  
Claudio Gandarias Zúñiga

Purpose: To assess if the suitability of endovascular aneurysm repair (EVAR) of ruptured abdominal aortic aneurysms (RAAAs) can be expanded by combining the Endurant stent-graft with the Heli-FX EndoAnchors. Materials and Methods: Contrast-enhanced computed tomography (CT) scans of 90 patients (mean age 73.2±9 years; 87 men) with RAAA admitted between January 2014 and January 2018 in 2 tertiary care centers were analyzed in a 3-dimensional workstation. Anatomical features of the aneurysms according to the instructions for use (IFU) for the Endurant endograft were evaluated and expansion of treatment with Heli-FX EndoAnchors was assessed. Results: Neck length <10 mm was present in 41 (45.6%) patients; 5 had neck diameters outside the IFU and 45 (50.0%) had conical necks. Thrombus and calcium were absent in 63 (70.0%) and 73 (81.1%), respectively. In the study cohort, 44 (48.9%) patients met all the neck criteria, although overall IFU compliance was found in only 35 (38.9%) patients due to iliac-related issues in 21 patients. The adjunctive use of EndoAnchors in the entire study group would enhance the therapeutic range to an additional 24 patients, 8 of whom would need an associated iliac procedure. This represents an expansion of the total EVAR approach from 48.9% to 75.6% of cases if some iliac issues are overcome and from 38.9% to 56.7% without correcting iliac deficiencies. Conclusion: The main reason of being unfit for endovascular treatment in this series was neck length <10 mm. Based on this analysis, nearly 40% of RAAA patients would have been candidates for EVAR based on the IFU neck criteria for the Endurant stent-graft. This suitability could be nearly doubled with the use of EndoAnchors and correction of unsuitable iliac anatomy. The use of EndoAnchors has the potential to offer a significant benefit in the endovascular treatment of RAAA patients.


Vascular ◽  
2020 ◽  
pp. 170853812094505
Author(s):  
Mario D’Oria ◽  
Filippo Griselli ◽  
Davide Mastrorilli ◽  
Filippo Gorgatti ◽  
Silvia Bassini ◽  
...  

Objectives The aim of this study was to report on the safety and feasibility of secondary relining with focal flaring of novel-generation balloon-expandable covered stents for endovascular treatment of significant diameter mismatch in the aorto-iliac territory. Significant diameter mismatch was defined as >20% difference in the nominal diameter between the intended proximal and distal landing zones. Methods Patient A was an 84-year-old man with prior abdominal aortic aneurysm open repair with a straight 20 mm Dacron tube. He presented with a right common iliac artery aneurysm (Ø88 mm) with contained rupture. The Gore Viabahn endoprosthesis (9 mm × 5 cm) was inserted proximally about 15 mm above the occluded ostium of the internal iliac artery. Subsequently, the BeGraft Aortic® (16 mm × 48 mm) was inserted proximally up to the common iliac artery origin; its proximal portion was flared to 22 mm. Patient B was a 77-year-old man with prior endovascular abdominal aortic aneurysm repair with a Medtronic Endurant stent-graft. He presented with occlusion of the right limb of the aortic endoprosthesis and thrombosis that extended down to the level of the superficial femoral artery. After mechanical thrombectomy, two Gore Viabahn endoprosthesis (first one, 8 mm × 10 cm; second one, 10 mm × 15 cm) were inserted into the right iliac limb. Subsequently, the BeGraft Aortic® (12mm × 39mm) was inserted proximally up to the gate of the aortic stent-graft; its proximal portion was flared to 16 mm. Results Technical success and clinical success were achieved in both patients. Imaging follow-up (6 months for Patient A, 12 months for Patient B) showed correct placement of all stent-grafts without any graft-related adverse event. The patients remained free from new reinterventions or recurrent symptoms. Patient A died 8 months after the index procedure from acute respiratory failure after community acquired pneumonia. Conclusion Secondary relining with focal flaring of novel-generation balloon-expandable covered stents for endovascular treatment of significant diameter mismatch in the aorto-iliac territory is safe and feasible. Although mid-term results seem to be effective, longer follow-up is warranted to establish durability of the technique.


2012 ◽  
Vol 19 (1) ◽  
pp. 58-66 ◽  
Author(s):  
Kylie E. Kvinlaug ◽  
D. Kirk Lawlor ◽  
Thomas L. Forbes ◽  
Rod Willoughby ◽  
Kent S. MacKenzie ◽  
...  

2015 ◽  
Vol 29 (5) ◽  
pp. 1021.e1-1021.e3 ◽  
Author(s):  
Tolga Demir ◽  
Mehmet Umit Ergenoglu ◽  
Nursen Tanrikulu ◽  
Ali Kubilay Korkut ◽  
Ergun Demirsoy

Sign in / Sign up

Export Citation Format

Share Document