scholarly journals Micro Optical Coherence Tomography for Coronary Imaging

2021 ◽  
Vol 8 ◽  
Author(s):  
Kensuke Nishimiya ◽  
Guillermo Tearney

Intravascular optical coherence tomography (IVOCT) that produces images with 10 μm resolution has emerged as a significant technology for evaluating coronary architectural morphology. Yet, many features that are relevant to coronary plaque pathogenesis can only be seen at the cellular level. This issue has motivated the development of a next-generation form of OCT imaging that offers higher resolution. One such technology that we review here is termed micro-OCT (μOCT) that enables the assessment of the cellular and subcellular morphology of human coronary atherosclerotic plaques. This chapter reviews recent advances and ongoing works regarding μOCT in the field of cardiology. This new technology has the potential to provide researchers and clinicians with a tool to better understand the natural history of coronary atherosclerosis, increase plaque progression prediction capabilities, and better assess the vessel healing process after revascularization therapy.

2020 ◽  
Vol 13 (8) ◽  
pp. 1848-1850
Author(s):  
Vikram Baruah ◽  
Aydin Zahedivash ◽  
Taylor Hoyt ◽  
Austin McElroy ◽  
Deborah Vela ◽  
...  

2019 ◽  
Vol 141 (9) ◽  
Author(s):  
Xiaoya Guo ◽  
Don P. Giddens ◽  
David Molony ◽  
Chun Yang ◽  
Habib Samady ◽  
...  

Medical image resolution has been a serious limitation in plaque progression research. A modeling approach combining intravascular ultrasound (IVUS) and optical coherence tomography (OCT) was introduced and patient follow-up IVUS and OCT data were acquired to construct three-dimensional (3D) coronary models for plaque progression investigations. Baseline and follow-up in vivo IVUS and OCT coronary plaque data were acquired from one patient with 105 matched slices selected for model construction. 3D fluid–structure interaction (FSI) models based on IVUS and OCT data (denoted as IVUS + OCT model) were constructed to obtain stress/strain and wall shear stress (WSS) for plaque progression prediction. IVUS-based IVUS50 and IVUS200 models were constructed for comparison with cap thickness set as 50 and 200 μm, respectively. Lumen area increase (LAI), plaque area increase (PAI), and plaque burden increase (PBI) were chosen to measure plaque progression. The least squares support vector machine (LS-SVM) method was employed for plaque progression prediction using 19 risk factors. For IVUS + OCT model with LAI, PAI, and PBI, the best single predictor was plaque strain, local plaque stress, and minimal cap thickness, with prediction accuracy as 0.766, 0.838, and 0.890, respectively; the prediction accuracy using best combinations of 19 factors was 0.911, 0.881, and 0.905, respectively. Compared to IVUS + OCT model, IVUS50, and IVUS200 models had errors ranging from 1% to 66.5% in quantifying cap thickness, stress, strain and prediction accuracies. WSS showed relatively lower prediction accuracy compared to other predictors in all nine prediction studies.


2021 ◽  
pp. 159101992110034
Author(s):  
Andre Monteiro ◽  
Demetrius K Lopes ◽  
Amin Aghaebrahim ◽  
Ricardo Hanel

Purpose Flow-diverters have revolutionized the endovascular treatment of intracranial aneurysms, offering a durable solution to aneurysms with high recurrence rates after conventional stent-assisted coiling. Events that occur after treatment with flow-diversion, such as in-stent stenosis (ISS) are not well understood and require further assessment. After assessing an animal model with Optical Coherence Tomography (OCT), we propose a concept that could explain the mechanism causing reversible ISS after treatment of intracranial aneurysms with flow-diverters. Methods Six Pipeline Flex embolization devices (PED-Flex), six PED with Shield technology (PED-Shield), and four Solitaire AB devices were implanted in the carotid arteries (two stents per vessel) of four pigs. Intravascular optical coherence tomography (OCT) and digital subtraction angiography (DSA) images obtained on day 21 were compared to histological specimens. Results A case of ISS in a PED-Flex device was assessed with OCT imaging. Neointima with asymmetrical topography completely covering the PED struts was observed. Histological preparations of the stenotic area demonstrated thrombus on the surface of device struts, covered by neointima. Conclusion This study provides a plausible concept for reversible ISS in flow-diverters. Based on an observation of a previous experiment, we propose that similar cases of ISS are related to thrombus presence underneath endothelization, but further experiments focused on this phenomenon are needed. Optical Coherence Tomography will be useful tool when available for clinical use.


2015 ◽  
Vol 234 (2) ◽  
pp. 91-100 ◽  
Author(s):  
Ik Soo Byon ◽  
Gang Yun Pak ◽  
Han Jo Kwon ◽  
Kyong Ho Kim ◽  
Sung Who Park ◽  
...  

Purpose: To investigate the natural history of idiopathic epiretinal membrane (ERM) in eyes with good visual function using optical coherence tomography (OCT). Methods: Sixty-two eyes of 58 patients with idiopathic ERM, visual acuity of 20/40 or better, and no significant metamorphopsia were included. The best corrected visual acuity (BCVA), central macular thickness (CMT), membrane configuration, and ellipsoid zone signal data over 24 months were retrospectively analyzed. Based on OCT findings, ERM configurations were categorized as global attachment (GA), partial attachment (PA), pseudohole, and vitreomacular traction (VMT). Results: The mean BCVA and CMT did not change significantly between baseline and 24 months. GA, PA, pseudohole, and VMT types were observed in 33, 19, 9, and 1 eye at baseline, and in 20, 22, 10, and 1 eye at 24 months, respectively. A membrane configuration change was noted in 24 eyes (38.7%) during follow-up, and the distribution shifted from GA to the other types (p < 0.001). Six eyes had visual loss due to membrane progression, and 4 eyes had spontaneous membrane separation. Of the 10 eyes with progression or separation, 6 were of the PA type. Conclusions: Although the BCVA remains stable over 2 years in most idiopathic ERM eyes with good visual function at baseline, the membrane configuration may change, affecting visual acuity. The GA type would be an early stage, and the PA type is prone to changes in visual acuity.