scholarly journals Flow Diversion for Intracranial Aneurysms Beyond the Circle of Willis

2021 ◽  
Vol 12 ◽  
Author(s):  
Jinlu Yu ◽  
Xianli Lv

Background: Few reports have shown the therapeutic outcomes of flow diversion (FD) for intracranial aneurysms beyond the circle of Willis, and the efficacy of this technique remains unclear.Materials and methods: A retrospective study was performed on 22 consecutive patients, diagnosed with intracranial aneurysms beyond the circle of Willis, and treated with pipeline embolization device (PED) (Medtronic, Irvine, California, USA) between January 2015 and December 2019.Result: The 22 patients were between 16 and 66 years old (mean 44.5 ± 12.7 years), and six patients were male (27.3%, 6/22). Twenty-two patients had 23 aneurysms. The 23 aneurysms were 3–25 mm in diameter (12.2 ± 7.1 mm on average). The diameter of the parent artery was 1.3–3.0 mm (2.0 ± 0.6 mm on average). The 23 aneurysms were located as follows: 17 (73.9%, 17/23) were in the anterior circulation, and 6 (26.1%, 6/23) were in the posterior circulation. PED deployment was technically successful in all cases. Two overlapping PEDs were used to cover the aneurysm neck in 3 cases. One PED was used to overlap the two tandem P1 and P2 aneurysms. Other cases were treated with single PED. Coil assistance was used to treat 7 aneurysms, including 4 recurrent aneurysms and 3 new cases requiring coiling assistance during PED deployment. There were no cases of complications during PED deployment. All patients were available at the follow-up (mean, 10.9 ± 11.4 months). All patients presented with a modified Rankin Score (mRS) of 0. During angiographic follow-up, complete embolization was observed in 22 aneurysms in 21 patients, and one patient had subtotal embolization with the prolongation of stasis in the arterial phase.Conclusion: PED deployment for intracranial aneurysms beyond the circle of Willis is feasible and effective, with high rates of aneurysm occlusion.

Stroke ◽  
2014 ◽  
Vol 45 (suppl_1) ◽  
Author(s):  
Ajay K Wakhloo ◽  
Pedro Lylyk ◽  
Joost de Vries ◽  
Matthew J Gounis ◽  
Alexandra Biondi ◽  
...  

Objective: Validated through experimental studies a new generation of flow diverters (Surpass™ FD) was evaluated for treatment of intracranial aneurysms (IA). We present our multicenter preliminary clinical and angiographic experience. METHODS: To achieve the calculated flow disruption between the parent artery and aneurysm for thrombosis, single FDs were placed endovascularly in parent arteries. Implants measured 2.5-5.3mm in diameter with a length of 10-80mm. Patients were enrolled harboring a wide range large and giant wide-neck, fusiform and multiple small and blister-type aneurysm. Clinical and angiographic follow-up were performed at 1-3, 6, and 12 months. RESULTS: A total of 186 consecutive IA in 161 patients (mean age 57.1 years) were treated at 33 centers. Fifty-three aneurysms were smaller than 5 mm, 64 were 5-9.9mm in diameter, 47 were 10-20mm in diameter, and 22 were larger than 20mm (10.4±0.7mm, neck size 6.0±0.5mm [mean±SEM]) . The aneurysms originated in 63.4% from the internal carotid artery; 22% and 14.5% of the lesions were located in the anterior circulation distal to Circle of Willis and posterior circulation respectively. Technical success was achieved in 182 aneurysms (98%); average number of devices used per aneurysm was 1.05. Permanent morbidity and mortality during the follow-up period of mean 8.4months (range 1-24 months) including periprocedural complications for patients with aneurysms of the anterior circulation were encountered in 5 (3.7%) and 2 (1.5 %) patients respectively and 1 (3.7%) and 4 (14.8%) respectively for patients with aneurysms of the posterior circulation location. One-hundred-ten patients (70.5%) harboring 127 (70.2%) were available for clinical and angiographic follow-up and showed a complete or near complete aneurysm occlusion in 63 (81.8%) of the ICA. Aneurysms of the ICA≥10mm that were completely covered by FD and not previously stent-treated with a minimum of 6 months follow-up available in 16 patients showed a complete obliteration in 81.3% (n=13) and >90% occlusion in remaining 3 patients. CONCLUSION: Preliminary data demonstrate high safety and efficacy of a new generation of FD for a wide range of IA of the anterior and posterior circulation with a single implant.


2018 ◽  
Vol 130 (1) ◽  
pp. 259-267 ◽  
Author(s):  
Matthew T. Bender ◽  
Geoffrey P. Colby ◽  
Li-Mei Lin ◽  
Bowen Jiang ◽  
Erick M. Westbroek ◽  
...  

OBJECTIVEFlow diversion requires neointimal stent overgrowth to deliver aneurysm occlusion. The existing literature on aneurysm occlusion is limited by heterogeneous follow-up, variable antiplatelet regimens, noninvasive imaging modalities, and nonstandard occlusion assessment. Using a large, single-center cohort with low attrition and standardized antiplatelet tapering, the authors evaluated outcomes after flow diversion of anterior circulation aneurysms to identify predictors of occlusion and aneurysm persistence.METHODSData from a prospective, IRB-approved database was analyzed for all patients with anterior circulation aneurysms treated by flow diversion with the Pipeline embolization device (PED) at the authors’ institution. Follow-up consisted of catheter cerebral angiography at 6 and 12 months postembolization. Clopidogrel was discontinued at 6 months and aspirin was reduced to 81 mg daily at 12 months. Occlusion was graded as complete, trace filling, entry remnant, or aneurysm filling. Multivariate logistic regression was performed to identify predictors of aneurysm persistence.RESULTSFollow-up catheter angiography studies were available for 445 (91%) of 491 PED procedures performed for anterior circulation aneurysms between August 2011 and August 2016. Three hundred eighty-seven patients accounted for these 445 lesions with follow-up angiography. The population was 84% female; mean age was 56 years and mean aneurysm size was 6.6 mm. Aneurysms arose from the internal carotid artery (83%), anterior cerebral artery (13%), and middle cerebral artery (4%). Morphology was saccular in 90% of the lesions, and 18% of the aneurysms has been previously treated. Overall, complete occlusion was achieved in 82% of cases at a mean follow-up of 14 months. Complete occlusion was achieved in 72%, 78%, and 87% at 6, 12, and 24 months, respectively. At 12 months, adjunctive coiling predicted occlusion (OR 0.260, p = 0.036), while male sex (OR 2.923, p = 0.032), aneurysm size (OR 3.584, p = 0.011), and incorporation of a branch vessel (OR 2.206, p = 0.035) predicted persistence. Notable variables that did not predict aneurysm occlusion were prior treatments, vessel of origin, fusiform morphology, and number of devices used.CONCLUSIONSThis is the largest single-institution study showing high rates of anterior circulation aneurysm occlusion after Pipeline embolization. Predictors of persistence after flow diversion included increasing aneurysm size and incorporated branch vessel, whereas adjunctive coiling predicted occlusion.


Neurosurgery ◽  
2009 ◽  
Vol 64 (5) ◽  
pp. E865-E875 ◽  
Author(s):  
Ronie L. Piske ◽  
Luis H. Kanashiro ◽  
Eric Paschoal ◽  
Celso Agner ◽  
Sergio S. Lima ◽  
...  

Abstract OBJECTIVE We report our results using Onyx HD-500 (Micro Therapeutics, Inc., Irvine, CA) in the endovascular treatment of wide-neck intracranial aneurysms, which have a high rate of incomplete occlusion and recanalization with platinum coils. METHODS Sixty-nine patients with 84 aneurysms were treated. Most of the aneurysms were located in the anterior circulation (80 of 84 aneurysms), were unruptured (74 of 84 aneurysms), and were incidental. Ten presented with subarachnoid hemorrhage, and 15 were symptomatic. All aneurysms had wide necks (neck >4 mm and/or dome-to-neck ratio <1.5). Fifty aneurysms were small (<12 mm), 30 were large (12 to <25 mm) and 4 were giant. Angiographic follow-up was available for 65 of the 84 aneurysms at 6 months, for 31 of the 84 aneurysms at 18 months, and for 5 of the 84 aneurysms at 36 months. RESULTS Complete aneurysm occlusion was seen in 65.5% of aneurysms on immediate control, in 84.6% at 6 months, and in 90.3% at 18 months. The rates of complete occlusion were 74%, 95.1%, and 95.2% for small aneurysms and 53.3%, 70%, and 80% for large aneurysms at the same follow-up periods. Progression from incomplete to complete occlusion was seen in 68.2% of all aneurysms, with a higher percentage in small aneurysms (90.9%). Aneurysm recanalization was observed in 3 patients (4.6%), with retreatment in 2 patients (3.3%). Procedural mortality was 2.9%. Overall morbidity was 7.2%. CONCLUSION Onyx embolization of intracranial wide-neck aneurysms is safe and effective. Morbidity and mortality rates are similar to those of other current endovascular techniques. Larger samples and longer follow-up periods are necessary.


2008 ◽  
Vol 109 (3) ◽  
pp. 445-453 ◽  
Author(s):  
Kivilcim Yavuz ◽  
Serdar Geyik ◽  
Isil Saatci ◽  
H. Saruhan Cekirge

Object The WingSpan stent is a new self-expandable neurovascular stent designed for endovascular treatment of intracranial atheromatous lesions. The authors report their experience with the use of this stent for the endovascular treatment of intracranial aneurysms. Methods Thirty-seven patients with 40 wide-necked intracranial aneurysms were treated using the WingSpan stent. Twenty-two aneurysms (55%) were small and 18 (45%) were large or giant. In all but 4 aneurysms, embolization was completed by packing the aneurysm sac with platinum coils. In 4 dissecting aneurysms that were fusiform or too small and wide necked to be catheterized, the stent was used alone. In these cases, the stent bridged the aneurysm neck to allow for flow redirection and the potential stent-induced endothelization effect. Results Follow-up angiograms obtained in 3 of 4 aneurysms, treated with only stent placement, demonstrated aneurysmal thrombosis and parent artery remodeling in 2 patients and moderate decrease in size in 1. Follow-up angiography obtained at 6 months to 1 year in 31 aneurysms after stent-supported coil embolization demonstrated complete occlusion in 23 aneurysms (74.2%) with a progressive thrombosis rate of 66.7% (10 of 15 aneurysms), and a recanalization rate of 16.1%. Conclusions In treating wide-necked intracranial aneurysms, the WingSpan Stent System is very flexible, secure, and effective. Its delivery system is very easy and exact in that it exerts higher outward radial force, thus providing an excellent conformability and a strong scaffold to hold the coils in place. It may offer an effective treatment when used alone in some fusiform or very wide-necked, small dissecting aneurysms in which other surgical or endovascular treatment strategies are not deemed feasible.


2018 ◽  
Vol 11 (1) ◽  
pp. 43-48 ◽  
Author(s):  
Brian M Howard ◽  
Jason M Frerich ◽  
Thomas P Madaelil ◽  
Jacques E Dion ◽  
Frank C Tong ◽  
...  

BackgroundAneurysmal subarachnoid hemorrhage is a potentially devastating condition, and among the first priorities of treatment is aneurysm occlusion to prevent re-hemorrhage. An emerging strategy to treat patients whose aneurysms are not ideal for surgical or endovascular treatment is subtotal coiling followed by flow diversion in the recovery phase or ‘plug and pipe’. However, data regarding the safety and efficacy of this strategy are lacking.MethodsA retrospective cohort study was performed to evaluate the efficacy and safety of ‘plug and pipe’. All patients with a ruptured intracranial aneurysm intentionally, subtotally treated by coiling in the acute stage followed by flow diversion after recovery, were included. The primary outcome was re-hemorrhage. Secondary outcomes included aneurysm occlusion and functional status. Complications were reviewed.Results22 patients were included. No patient suffered a re-hemorrhage, either in the interval between coiling and flow diversion or in follow-up. The median interval between aneurysm rupture and flow diversion was 3.5 months. Roy–Raymond (R-R) class I or II occlusion was achieved in 91% of target aneurysms at the last imaging follow-up (15/22(68%) R-R 1 and 5/22(23%) R-R 2). Complications occurred in 2 (9%) patients, 1 of which was neurological.ConclusionsOverall, these data suggest that subtotal coiling of ruptured intracranial aneurysms followed by planned flow diversion is both safe and effective. Patients who may most benefit from ‘plug and pipe’ are those with aneurysms that confer high operative risk and those whose severity of medical illness increases the risk of microsurgical clip ligation.


1998 ◽  
Vol 5 (4) ◽  
pp. E5 ◽  
Author(s):  
Giuseppe Lanzino ◽  
Ajay K. Wakhloo ◽  
Richard D. Fessler ◽  
Robert A. Mericle ◽  
Lee R. Guterman ◽  
...  

Results of previous in vitro and in vivo experimental studies have suggested that the placement of a porous stent within the parent artery across the aneurysm neck may hemodynamically uncouple the aneurysm from the parent vessel, leading to thrombosis of the aneurysm. For complex wide-necked aneurysms, a stent may also aid the packing of the aneurysm with Guglielmi detachable coils (GDCs) by acting as a rigid scaffold that prevents coil herniation into the parent vessel. Recently, improved stent system delivery technology has allowed access to the tortuous vascular segments of the intracranial system. The authors report here the intracranial stenting of aneurysms involving different segments of the internal carotid artery (ICA) and the vertebral artery (VA). Four patients with intracranial aneurysms located at the petrous, cavernous, and paraclinoid segments of the ICA and at the VA proximal to the origin of the posterior inferior cerebellar artery, respectively, were treated since January 1998. In three of these patients, stent placement across the aneurysm neck was followed by GDC placement, accomplished via a microcatheter through stent mesh. In one patient, the aneurysm was treated solely by stenting. No periprocedural complications were observed, and at follow up, no patient was found to have suffered symptoms referable to aneurysm growth or thromboembolic complications. More than 90% occlusion of the aneurysm was achieved in the three cases treated by stenting and GDC placement. One of these patients underwent 6-month follow-up angiography that did not reveal any in-stent stenosis. In the case treated solely by stent placement, no evidence of aneurysm thrombosis was observed either immediately postprocedure or on follow-up angiography performed 24 hours later. A new generation of flexible stents can be used to treat intracranial aneurysms in difficult-to-access areas such as the proximal intracranial segments of the ICA or the VA. The stent allows tight coil packing even in the presence of a wide-necked, irregularly shaped aneurysm and may provide an endoluminal matrix for endothelial growth. Although convincing experimental evidence suggests that stent placement across the aneurysm neck may by itself promote intraluminal thrombosis, the role of this phenomenon in clinical practice may be limited at present by the high porosity of currently available stents.


2018 ◽  
Vol 11 (3) ◽  
pp. 290-295 ◽  
Author(s):  
Lukas Goertz ◽  
Franziska Dorn ◽  
Bastian Kraus ◽  
Jan Borggrefe ◽  
Marc Schlamann ◽  
...  

BackgroundThe Derivo Embolization Device (DED) is a novel flow diverter with advanced X-ray visibility, potentially lower thrombogenicity, and an improved delivery system.ObjectiveTo evaluate the safety and efficacy of the DED for emergency treatment of ruptured intracranial aneurysms.MethodsBetween February 2016 and March 2018, 10 patients (median age 54.5 years, seven women) with 11 aneurysms were treated with the DED at three neurovascular centers. Procedural details, complications, morbidity, and aneurysm occlusion (O’Kelly-Marotta scale, OKM) were retrospectively reviewed.ResultsAmong 11 aneurysms treated, there were nine anterior circulation and two posterior circulation aneurysms. Aneurysm morphology was saccular in four cases, dissecting in three, blister-like in three, and fusiform in one. In each case, a single DED was implanted and deployment was technically successful without exception. Adjunctive coiling was performed in two aneurysms. We observed one in-stent thrombosis, presumably due to low response to clopidogrel 4 days after the procedure, which remained with a mild hemiparesis after aspiration thrombectomy. No further thromboembolic or hemorrhagic events occurred. Favorable outcome (modified Rankin scale score ≤2) at last follow-up was achieved in all patients. Among 10 aneurysms available for angiographic follow-up, complete aneurysm occlusion (OKM D) was obtained in nine cases (90.0%).ConclusionsIn this pilot study, endovascular treatment of ruptured intracranial aneurysms with the DED was feasible and not associated with any incidence of rebleeding. Larger series with longer follow-up are warranted to reach a definite conclusion about this device.


2016 ◽  
Vol 9 (3) ◽  
pp. 311-315 ◽  
Author(s):  
R Fahed ◽  
J C Gentric ◽  
I Salazkin ◽  
G Gevry ◽  
J Raymond ◽  
...  

BackgroundFlow diverters (FDs) are increasingly used for bifurcation aneurysms. Failure of aneurysm occlusion may be caused by residual flow maintaining patency of the jailed branch along with the aneurysm. Our aim was to test whether endovascular occlusion of the jailed branch could improve efficacy of flow diversion of bifurcation aneurysms.Materials and methodsSixteen wide-necked lingual–carotid artery bifurcation aneurysms were created in eight canines. Patent aneurysms were randomly allocated 4 weeks later to flow diversion combined with jailed branch occlusion using coils and/or Onyx (n=6) or flow diversion alone (n=8). Angiographic results of aneurysm occlusion at 3 months were scored using an ordinal scale. Pathology specimens were photographed and neointimal coverage estimated using a semiquantitative scoring system.ResultsFourteen aneurysms were patent at 1 month. FD deployment was successful in all cases but, at 3-month follow-up, three devices had prolapsed into the aneurysm. None of the bifurcation aneurysms treated with FD alone were occluded at 3 months. Endovascular branch occlusion combined with flow diversion significantly improved aneurysm occlusion rates compared with flow diversion alone (median angiographic scores 2 vs 0: p=0.0137). Flow-limiting parent vessel stenosis was not observed in any arteries. Devices were covered with thick neointima in most cases, but patent aneurysms were associated with leaks or holes in the neointima covering the aneurysm neck.ConclusionsTreatment failures following flow diversion of bifurcation aneurysms can be caused by persistent flow to the jailed branch. Branch occlusion combined with flow diversion may improve angiographic occlusion scores of a canine bifurcation aneurysm model.


2015 ◽  
Vol 122 (6) ◽  
pp. 1498-1502 ◽  
Author(s):  
Nohra Chalouhi ◽  
Mario Zanaty ◽  
Alex Whiting ◽  
Steven Yang ◽  
Stavropoula Tjoumakaris ◽  
...  

OBJECT Flow diverters are increasingly used for treatment of intracranial aneurysms. In most series, the Pipeline Embolization Device (PED) was used for the treatment of large, giant, complex, and fusiform aneurysms. Little is known about the use of the PED in small aneurysms. The purpose of this study was to assess the safety and efficacy of the PED in small aneurysms (≤ 7 mm). METHODS A total of 100 consecutive patients were treated with the PED at the authors' institution between May 2011 and September 2013. Data on procedural safety and efficacy were retrospectively collected. RESULTS The mean aneurysm size was 5.2 ± 1.5 mm. Seven patients (7%) had sustained a subarachnoid hemorrhage. All except 5 aneurysms (95%) arose from the anterior circulation. The number of PEDs used was 1.2 per aneurysm. Symptomatic procedure-related complications occurred in 3 patients (3%): 1 distal parenchymal hemorrhage that was managed conservatively and 2 ischemic events. At the latest follow-up (mean 6.3 months), 54 (72%) aneurysms were completely occluded (100%), 10 (13%) were nearly completely occluded (≥ 90%), and 11 (15%) were incompletely occluded (< 90%). Six aneurysms (8%) required further treatment. Increasing aneurysm size (OR 3.8, 95% CI 0.99–14; p = 0.05) predicted retreatment. All patients achieved a favorable outcome (modified Rankin Scale Score 0–2) at follow-up. CONCLUSIONS In this study, treatment of small aneurysms with the PED was associated with low complication rates and high aneurysm occlusion rates. These findings suggest that the PED is a safe and effective alternative to conventional endovascular techniques for small aneurysms. Randomized trials with long-term follow-up are necessary to determine the optimal treatment that leads to the highest rate of obliteration and the best clinical outcomes.


2019 ◽  
Vol 11 (10) ◽  
pp. 1004-1008 ◽  
Author(s):  
Matthew James Kole ◽  
Timothy Ryan Miller ◽  
Gregory Cannarsa ◽  
Aaron Wessell ◽  
Salazar Jones ◽  
...  

ObjectiveFlow diversion using the Pipeline embolization device (PED) has become a widely used treatment method for intracranial aneurysms. However, a subset of aneurysms will fail to occlude following treatment and the factors that influence the efficacy of flow diversion remain uncertain. As smaller diameter PEDs inherently have greater metal density than larger devices, we elected to investigate whether PED diameter influences treatment efficacy when using a single device. We also evaluated other factors that may influence treatment outcomes with PED.MethodsWe retrospectively evaluated all patients treated for an intracranial saccular aneurysm at our institution with a single PED at least 12 months prior to the time of data collection. Patients treated with multiple devices, adjunctive coiling, traumatic and fusiform target aneurysms, as well as patients with inadequate imaging follow-up (<12 months) were excluded.Results158 aneurysms in 124 patients (128 treatments) met the inclusion criteria for our study. 123 aneurysms (80%) were occluded over an average follow-up of 26.6 months. Multivariable logistic regression showed that branch vessel incorporation into the target aneurysm sac (p<0.001, OR=0.15) was significantly associated with aneurysm persistence, while smaller PED diameter was significantly associated with aneurysm occlusion (p=0.008; OR=0.30).ConclusionsPED diameter significantly impacts outcomes when using a single device for the treatment of small anterior circulation intracranial saccular aneurysms, most likely due to the inherent greater metal density of smaller devices. This factor should be taken into account when planning endovascular aneurysm treatment with PED.


Sign in / Sign up

Export Citation Format

Share Document