scholarly journals Assessment of Conducted Emission for Multiple Compact Fluorescent Lamps in Various Grid Topology

Electronics ◽  
2021 ◽  
Vol 10 (18) ◽  
pp. 2258
Author(s):  
Lok Choon Long ◽  
Waseem El Sayed ◽  
Venkatkumar Munesswaran ◽  
Niek Moonen ◽  
Robert Smolenski ◽  
...  

This paper presents the measurement of aggregated conducted emission in the frequency range of 9 kHz to 150 kHz produced by multiple compact fluorescent lamps (CFL) and how it equates to a multiple power converter system. Discrepancies in peak emission measurement results related to this application are illustrated to understand the underlying issue related to volatility of frequency components. Furthermore, this knowledge analyzes the relation of electromagnetic disturbances with respect to different topological network connections. The final presented results constitute theoretical description and statistical information about the characteristics of conducted emission measured in this multi-converter system.


Energy ◽  
2009 ◽  
Vol 34 (9) ◽  
pp. 1355-1363 ◽  
Author(s):  
J. Trifunovic ◽  
J. Mikulovic ◽  
Z. Djurisic ◽  
M. Djuric ◽  
M. Kostic


2015 ◽  
Vol 35 (1Sup) ◽  
pp. 89-97 ◽  
Author(s):  
Gabriel Alexis Malagon ◽  
Jeisson Bello Peña ◽  
Gabriel Ordóñez Plata ◽  
Cesar Duarte Gualdrón

<p class="MsoNormal" style="text-align: justify;"><span style="font-family: 'Century Gothic', sans-serif; font-size: 8pt; letter-spacing: -0.1pt;"><span style="font-family: OptimaLTStd; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;">This article presents an analysis and discussion on the performance of a circuit-based model for Compact Fluorescent Lamps (CFL) <span style="font-family: OptimaLTStd; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;">in a 120V 60Hz power grid. This model is proposed and validated in previous scientific literature for CFLs in 230V 50Hz systems. <span style="font-family: OptimaLTStd; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;">Nevertheless, the derivation of this model is not straightforward to follow and its performance in 120V 60Hz systems is a matter of <span style="font-family: OptimaLTStd; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;">research work. In this paper, the analytical derivation of this CFL model is presented in detail and its performance is discussed when <span style="font-family: OptimaLTStd; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;">predicting the current of a CFL designed to operate in a 120V 60Hz electrical system. The derived model is separately implemented <span style="font-family: OptimaLTStd; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;">in both MATLAB<span style="font-family: OptimaLTStd; font-size: 5pt; color: #231f20; font-style: normal; font-variant: normal;">® <span style="font-family: OptimaLTStd; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;">and ATP-EMTP<span style="font-family: OptimaLTStd; font-size: 5pt; color: #231f20; font-style: normal; font-variant: normal;">® <span style="font-family: OptimaLTStd; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;">software using two different sets of parameters previously proposed for 230V 50Hz CFLs. These <span style="font-family: OptimaLTStd; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;">simulation results are compared against laboratory measurements using a programmable AC voltage source. The measurements <span style="font-family: OptimaLTStd; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;">and simulations considered seven CFLs 110/127V 60Hz with different power ratings supplied by a sinusoidal (not distorted) voltage <span style="font-family: OptimaLTStd; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;">source. The simulations under these conditions do not properly predict the current measurements and therefore the set of parameters <span style="font-family: OptimaLTStd; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;">and/or the model itself need to be adjusted for 120V 60Hz power grids.</span></span></span></span></span></span></span></span></span><br style="font-style: normal; font-variant: normal; font-weight: normal; letter-spacing: normal; line-height: normal; orphans: 2; text-align: -webkit-auto; text-indent: 0px; text-transform: none; white-space: normal; widows: 2; word-spacing: 0px; -webkit-text-size-adjust: auto; -webkit-text-stroke-width: 0px;" /></span></span></span></span></span></span></p>





Sign in / Sign up

Export Citation Format

Share Document