scholarly journals Unified Power Flow Controller Based on Autotransformer Structure

Electronics ◽  
2019 ◽  
Vol 8 (12) ◽  
pp. 1542
Author(s):  
Hyun-Jun Lee ◽  
Dae-Shik Lee ◽  
Young-Doo Yoon

This paper proposes a new unified power flow controller (UPFC) topology. A single phase of them system with the proposed topology consists of an N:2 transformer with a center tap at the low-voltage side and a power converter module comprising full- and half-bridge converters. A three-phase system can be implemented with three devices. While the conventional UPFC topology uses two three-phase transformers, which are called series and parallel transformers, the proposed topology utilizes three single-phase transformers to implement a three-phase UPFC system. By using an autotransformer structure, the power rating of the transformers and the voltage rating of switches in the power converter module can be significantly decreased. As a result, it is possible to reduce the installation spaces and costs compared with the conventional UPFC topology. In addition, by adopting a full- and half-bridge converter structure, the proposed topology can be easily implemented with conventional power devices and control techniques. The techniques used to control the proposed topology are described in this paper. The results obtained from simulations and experiments verify the effectiveness of the proposed UPFC topology.

Author(s):  
Subramani C ◽  
S. S. Dash ◽  
Vimala C ◽  
Uma Mageshwari

<p>In this paper we presents a new component within the flexible ac-transmission system (FACTS) family, called Distributed Power-Flow Controller (DPFC). The DPFC is derived from the unified power-flow controller (UPFC). The DPFC can be considered as a UPFC with an eliminated common dc link. The active power exchange between the shunt and series converters, which is through the common dc link in the UPFC, is now through the transmission lines at the third-harmonic frequency. The DPFC employs the distributed FACTS (DFACTS) concept, which is to use multiple small-size single-phase converters instead of the one large-size three-phase series converter in the UPFC. The large number of series converters provides redundancy, thereby increasing the system reliability. As the D-FACTS converters are single-phase and floating with respect to the ground, there is no high-voltage isolation required between the phases. Accordingly, the cost of the DPFC system is lower than the UPFC. The DPFC has the same control capability as the UPFC, which comprises the adjustment of the line impedance, the transmission angle, and the bus voltage. The controller is designed to achieve the most appropriate operating point based on the real power priority.</p>


2008 ◽  
Vol 8 (3) ◽  
pp. 503-509 ◽  
Author(s):  
N.F. Mailah ◽  
S.M. Bashi ◽  
N. Mariun ◽  
I. Aris

Sign in / Sign up

Export Citation Format

Share Document