scholarly journals Design and Hardware-in-the-Loop Implementation of Fuzzy-Based Proportional-Integral Control for the Traction Line-Side Converter of a High-Speed Train

Energies ◽  
2019 ◽  
Vol 12 (21) ◽  
pp. 4094 ◽  
Author(s):  
Qixiang Yan ◽  
Ibrahim Adamu Tasiu ◽  
Hong Chen ◽  
Yuting Zhang ◽  
Siqi Wu ◽  
...  

Power quality is one of many issues affecting the traction power supply system. Prominent among the causes of poor power quality is voltage low-frequency oscillation (VLFO). In this paper, a fuzzy-based PI (FPI) controller to optimize the performance of the traction line-side converter (TLSC) and suppress the effect of VLFO is proposed. Firstly, the mathematical model of China’s railway high-speed five single-phase TLSC is developed, and then the FPI control unit is designed based on specific requirements. The fuzzy antecedent and consequence rules were generated based on the expert and previous knowledge of TLSC operation. An offline simulation of the proposed control scheme under different loads and parameters is conducted to verify the designed. To validate the model, the traction power supply system (TPS) is built on the field-programmable gate array (FPGA) real-time digital simulator (FPGA-RTDS), while the FPI control algorithm is load on modeling tech rapid control prototyping (RCP) real-time digital controller (RTDC). Hardware-in-the-loop (HIL), and offline simulation studies between current decoupling (PI) control, sliding mode control (SMC), and the proposed control method confirms in addition to excellent dynamic performance; the proposed method can successfully suppress the effect of VLFO.

Energies ◽  
2021 ◽  
Vol 14 (1) ◽  
pp. 253
Author(s):  
Si Wu ◽  
Mingli Wu ◽  
Yi Wang

The existing problems of the traction power-supply system (i.e., the existence of the neutral section and the power quality problems) limit the development of railways, especially high-speed railways, which are developing rapidly worldwide. The existence of the neutral section leads to the speed loss and traction loss as well as mechanical failures, all of which threaten the fast and safe operation of the train and the system. Meanwhile, the power quality problems (e.g., the negative sequence current, the reactive power, and the harmonic) can bring a series of problems that cannot be ignored on the three-phase grid side. In response, many researchers have proposed co-phase power-supply schemes to solve these two problems simultaneously. Given that the auto-transformer (AT) power-supply mode has become the main power-supply mode for the high-speed railway traction power-supply system, it has a bright future following the rapid development of the high-speed railway. In addition, there is no co-phase power-supply scheme designed for AT power-supply mode in the existing schemes. Therefore, the main contribution of this paper is to propose a specifically designed power-supply mode more suitable for the AT, as well as to establish the control systems for the rectifier side and the inverter side. In addition, for the proposed scheme, the operation principle is analyzed, the mathematical model is built, and the control system is created, and its functionality is verified by simulation, and its advantages are compared and summarized finally. The result proves that it can meet functional requirements. At the same time, compared with the existing co-phase power-supply scheme, it saves an auto-transformer in terms of topology, reduces the current stress by 10.9% in terms of the current stress of the switching device, and reduces the power loss by 0.25% in terms of the entire system power loss, which will result in a larger amount of electricity being saved. All of this makes it a more suitable co-phase power-supply scheme for the AT power-supply mode.


Sign in / Sign up

Export Citation Format

Share Document