power supply system
Recently Published Documents


TOTAL DOCUMENTS

2287
(FIVE YEARS 764)

H-INDEX

30
(FIVE YEARS 5)

2022 ◽  
Vol 1 (15) ◽  
pp. 22-28
Author(s):  
Igor' Golovanov ◽  
Alena Alekseeva ◽  
Vladimir Proskuryakov ◽  
Roman Samchuk

Electrical circuits of reactive power compensation on the basis of thyristor control circuits in the power supply system of oil refineries are considered. The main advantages, advantages over traditional reactive power compensation systems and directions of introduction into the power supply system of modern production are formulated.


2022 ◽  
Vol 1 (15) ◽  
pp. 12-14
Author(s):  
Dmitriy Babich ◽  
Valeriy Sartakov

Structuring of the undergraduate program block related to the practical training traversed by students at electric power enterprises in the light of a new vision for the training of a modern engineer using the Moodle distance learning system and modern case study methodology is considered.


2022 ◽  
Vol 1 (15) ◽  
pp. 8-11
Author(s):  
Oleg Arsent'ev ◽  
Yuliya Shalashova ◽  
Denis Zaycev

The features of power supply for oil and gas enterprises, the design, features of the operation of gas turbine plants, methods of organizing a power supply system with elements of its own generation are considered, an autonomous power system with the organization of a direct cur-rent link has been developed to ensure stable operation of gas turbine units operating in paral-lel.


2022 ◽  
Vol 1049 ◽  
pp. 311-316
Author(s):  
Andrei Yu. Mokryak ◽  
Anna V. Mokryak ◽  
Soslan V. Skodtaev ◽  
Tatiana V. Safonova

An electrical installation that simulates an automobile DC power supply system with a voltage of 12 V has been created. An experimental simulation of a short circuit at currents up to 400 A on copper multi-wire and single-wire conductors under normal environmental conditions is carried out. The copper wires beads were annealed in a furnace at temperatures from 700 to 1000 °C for 20, 40 and 60 minutes. Metallographic analysis of copper wires beads was carried out. The temperatures and times that of at which the signs of short circuit and overcurrent are destroyed has been revealed. Obtained results contribute to improvement evidence’s researching in the fire investigation of motor vehicles electrical wiring after a fire. Keywords: Arc beads, Copper, Metallographic analysis, Electrical Short Circuit, Wires.


Author(s):  
Yu. N. Bulatov ◽  
A. V. Kryukov ◽  
K. V. Suslov

THE PURPOSE. Investigation of the operating modes of an isolated power supply system with controlled distributed generation plants, energy storage units and a drive load. Determination of the influence of the proposed prognostic controller of a distributed generation plant on the control parameters and quality indicators of the control process under various operating modes of an isolated power supply system.METHODS. The studies were carried out on a computer model of an isolated power supply system of an industrial enterprise with a turbine generator plant, a wind generator plant and a high-power electric storage unit, for which a fuzzy control system and a prognostic controller were used. The simulation was performed in MATLAB using Simulink and SimPowerSystems packages.RESULTS. The article describes a computer model of an isolated power supply system, as well as a structural diagram of the proposed autoprognostic speed controller. The simulation results showed that the combined use of an energy storage unit and an auto-prognostic generator rotor speed controller makes it possible to ensure the stability and survivability of an isolated power supply system, increasing its damping properties. The use of a fuzzy control system of a wind-generating plant made it possible to ensure its stable operation in all considered modes.CONCLUSION. The auto-prognostic speed controller, which does not require special settings, and the energy storage unit provide high quality control indicators in normal and emergency modes. It is advisable to conduct further studies to coordinate the actions of the control system of the electric energy storage unit and the auto-prognostic speed controller of the distributed generation plant.


2022 ◽  
Vol 355 ◽  
pp. 03060
Author(s):  
Hong Cui ◽  
Youqing Gao

A large number of harmonics will be generated in the process of transforming high frequency and high voltage alternating current (AC) into a constant frequency and constant voltage through a power conversion system when the high-speed motor is used as a generator. The phase-shifting reactor is used to eliminate harmonics for high-speed generator power conversion systems, and LCL filter and adjustable inductance filter are used to eliminate harmonics for high-speed motor power supply system in this paper. The adjustable inductance filter can adjust the inductance value in time according to the change of the output frequency of the inverter. The results verify the effectiveness of the methods used, and provide a theoretical basis for the wide application of high-speed motor by simulation.


Author(s):  
Odudu O. C.

Abstract: The aim of this research is to use a combination of renewable energy sources and conventional diesel generator to model a cost effective, alternative energy source for telecommunication base stations in Nigeria. Actually, this study uses various theoretical and mathematical modelling tools, such as, Mat lab Simulink and HOMER software. In the same way, the study references several Base Transceiver Stations (BTS) from gsm providers at select geographical locations in Rivers State. The study references BTS infrastructure in locations such as Ogoni, Port Harcourt and Emohua. These locations were selected to reflect different climatic conditions in Rivers state. Against this background, various hybrid combinations comprising at least two sources of renewable energy e.g Wind Turbine generator(WTG) and Solar Photovoltaic (SPV) were modelled. Also, Fuzzy logic optimization algorithm was used in tracking the maximum power in the SPV. A sample Diesel Generator(DG) was studied to analyze which possible combination gives optimum performance and is most cost effective. The total cost for installation and maintenance of the hybrid system was also considered. Consequently, one of the common negative effects of conventional power generation and usage, which is environmental pollution, was also highlighted during the study. In the course of this research, Homer was used to model a hybrid system in which the initial capital Cost (ICC) was N101,517,040 for 96 nos battery, 1 no 10kw WTG, 1 no hydro-turbine, 48 nos converters, labour etc. The replacement cost for component has a depreciation of 30%; while maintenance for diesel is 30% of the ICC. Eventually, the results obtained from the simulations showed that with an increase in supply from renewable energy sources the overall cost spent when compared to using a diesel generator only is cut by 50%, while the pollution effects also dropped. In fact, the cost also reduces if the renewable energy system is designed efficiently to track and harness maximum power. Furthermore, it is also evident that the location of the base station site and the availability of Renewable energy source affects the efficiency and cost of the entire system. Hence, it is recommended that any telecommunication company which intends installing a hybrid power system for its base stations must carry out detailed feasibility studies using input parameters described here; especially, as it relates to siting of base stations in rural off-grid areas. Keywords: Hybrid Power Supply System