scholarly journals First-Step PPG Signal Analysis for Evaluation of Stress Induced during Scanning in the Open-Air MRI Device

Sensors ◽  
2020 ◽  
Vol 20 (12) ◽  
pp. 3532
Author(s):  
Jiří Přibil ◽  
Anna Přibilová ◽  
Ivan Frollo

The paper describes first-step experiments with parallel measurement of cardiovascular parameters using a photoplethysmographic optical sensor and standard portable blood pressure monitors in different situations of body relaxation and stimulation. Changes in the human cardiovascular system are mainly manifested by differences in the Oliva–Roztocil index, the instantaneous heart rate, and variations in blood pressure. In the auxiliary experiments, different physiological and psychological stimuli were applied to test whether relaxation and activation phases produce different measured parameters suitable for further statistical analysis and processing. The principal investigation is aimed at analysis of vibration and acoustic noise impact on a physiological and psychological state of a person lying inside the low-field open-air magnetic resonance imager (MRI). The obtained results will be used to analyze, quantify, and suppress a possible stress factor that has an impact on the speech signal recorded during scanning in the MRI device in the research aimed at 3D modeling of the human vocal tract.

Proceedings ◽  
2019 ◽  
Vol 42 (1) ◽  
pp. 14
Author(s):  
Jiří Přibil ◽  
Anna Přibilová ◽  
Ivan Frollo

The paper represents a preliminary analysis of the physiological and psychological impact of vibration and acoustic noise on a person examined by a low-field magnetic resonance imaging (MRI) tomograph. First, a methodology for the measurement of different signals of a tested person was found. The main investigation consists of a parallel heart rate and blood pressure measurement using a photoplethysmographic (PPG) optical sensor and standard portable blood pressure monitors. The recorded PPG signal is filtered and processed to obtain a clean waveform used to determine an instantaneous heart rate. Different types of portable blood pressure monitors are tested and compared to choose the best one for further experiments.


2000 ◽  
Vol 39 (02) ◽  
pp. 118-121 ◽  
Author(s):  
S. Akselrod ◽  
S. Eyal

Abstract:A simple nonlinear beat-to-beat model of the human cardiovascular system has been studied. The model, introduced by DeBoer et al. was a simplified linearized version. We present a modified model which allows to investigate the nonlinear dynamics of the cardiovascular system. We found that an increase in the -sympathetic gain, via a Hopf bifurcation, leads to sustained oscillations both in heart rate and blood pressure variables at about 0.1 Hz (Mayer waves). Similar oscillations were observed when increasing the -sympathetic gain or decreasing the vagal gain. Further changes of the gains, even beyond reasonable physiological values, did not reveal another bifurcation. The dynamics observed were thus either fixed point or limit cycle. Introducing respiration into the model showed entrainment between the respiration frequency and the Mayer waves.


2013 ◽  
Vol 7 (6) ◽  
pp. 448-453 ◽  
Author(s):  
Cedric Edwards ◽  
Swapnil Hiremath ◽  
Ankur Gupta ◽  
Brendan B. McCormick ◽  
Marcel Ruzicka

Author(s):  
Arundhati Goley ◽  
A. Mooventhan ◽  
NK. Manjunath

Abstract Background Hydrotherapeutic applications to the head and spine have shown to improve cardiovascular and autonomic functions. There is lack of study reporting the effect of either neutral spinal bath (NSB) or neutral spinal spray (NSS). Hence, the present study was conducted to evaluate and compare the effects of both NSB and NSS in healthy volunteers. Methods Thirty healthy subjects were recruited and randomized into either neutral spinal bath group (NSBG) or neutral spinal spray group (NSSG). A single session of NSB, NSS was given for 15 min to the NSBG and NSSG, respectively. Assessments were taken before and after the interventions. Results Results of this study showed a significant reduction in low-frequency (LF) to high-frequency (HF) (LF/HF) ratio of heart rate variability (HRV) spectrum in NSBG compared with NSSG (p=0.026). Within-group analysis of both NSBG and NSSG showed a significant increase in the mean of the intervals between adjacent QRS complexes or the instantaneous heart rate (HR) (RRI) (p=0.002; p=0.009, respectively), along with a significant reduction in HR (p=0.002; p=0.004, respectively). But, a significant reduction in systolic blood pressure (SBP) (p=0.037) and pulse pressure (PP) (p=0.017) was observed in NSSG, while a significant reduction in diastolic blood pressure (DBP) (p=0.008), mean arterial blood pressure (MAP) (p=0.008) and LF/HF ratio (p=0.041) was observed in NSBG. Conclusion Results of the study suggest that 15 min of both NSB and NSS might be effective in reducing HR and improving HRV. However, NSS is particularly effective in reducing SBP and PP, while NSB is particularly effective in reducing DBP and MAP along with improving sympathovagal balance in healthy volunteers.


2019 ◽  
Vol 201 ◽  
pp. 06003
Author(s):  
Łukasz Stala ◽  
Krzysztof Tomczuk

The paper presents two methods of determining calibration curve of a new device for blood pressure measurement. The device was developed at Wrocław University of Science and Technology. First method is based on parallel measurement of systolic and diastolic pressure measurement with use of reference device such as sphygmomanometer and researched new device with pneumatic sensor equipped with voltage type output. Obtained data (systolic ps and diastolic pd pressure, maximum us and minimum ud voltage) was then used to determine individual pressure-voltage characteristic of the device, which can be represented as a linear equation. Second method is based on substitution of experimentally proved coefficient b with its analytical equivalent extracted from mathematical model of described pneumatic sensor. Described methods were verified experimentally and compared. Metrological parameters of the device were designated.


Sign in / Sign up

Export Citation Format

Share Document