scholarly journals A Novel Hybrid Methodology of Measuring Sentence Similarity

Symmetry ◽  
2021 ◽  
Vol 13 (8) ◽  
pp. 1442
Author(s):  
Yongmin Yoo ◽  
Tak-Sung Heo ◽  
Yeongjoon Park ◽  
Kyungsun Kim

The problem of measuring sentence similarity is an essential issue in the natural language processing area. It is necessary to measure the similarity between sentences accurately. Sentence similarity measuring is the task of finding semantic symmetry between two sentences, regardless of word order and context of the words. There are many approaches to measuring sentence similarity. Deep learning methodology shows a state-of-the-art performance in many natural language processing fields and is used a lot in sentence similarity measurement methods. However, in the natural language processing field, considering the structure of the sentence or the word structure that makes up the sentence is also important. In this study, we propose a methodology combined with both deep learning methodology and a method considering lexical relationships. Our evaluation metric is the Pearson correlation coefficient and Spearman correlation coefficient. As a result, the proposed method outperforms the current approaches on a KorSTS standard benchmark Korean dataset. Moreover, it performs a maximum of a 65% increase than only using deep learning methodology. Experiments show that our proposed method generally results in better performance than those with only a deep learning model.

2021 ◽  
Author(s):  
Yoojoong Kim ◽  
Jeong Moon Lee ◽  
Moon Joung Jang ◽  
Yun Jin Yum ◽  
Jong-Ho Kim ◽  
...  

BACKGROUND With advances in deep learning and natural language processing, analyzing medical texts is becoming increasingly important. Nonetheless, a study on medical-specific language models has not yet been conducted given the importance of medical texts. OBJECTIVE Korean medical text is highly difficult to analyze because of the agglutinative characteristics of the language as well as the complex terminologies in the medical domain. To solve this problem, we collected a Korean medical corpus and used it to train language models. METHODS In this paper, we present a Korean medical language model based on deep learning natural language processing. The proposed model was trained using the pre-training framework of BERT for the medical context based on a state-of-the-art Korean language model. RESULTS After pre-training, the proposed method showed increased accuracies of 0.147 and 0.148 for the masked language model with next sentence prediction. In the intrinsic evaluation, the next sentence prediction accuracy improved by 0.258, which is a remarkable enhancement. In addition, the extrinsic evaluation of Korean medical semantic textual similarity data showed a 0.046 increase in the Pearson correlation. CONCLUSIONS The results demonstrated the superiority of the proposed model for Korean medical natural language processing. We expect that our proposed model can be extended for application to various languages and domains.


Author(s):  
K.G.C.M Kooragama ◽  
L.R.W.D. Jayashanka ◽  
J.A. Munasinghe ◽  
K.W. Jayawardana ◽  
Muditha Tissera ◽  
...  

2021 ◽  
Author(s):  
Dilith Sasanka ◽  
H. K. N Malshani ◽  
Uchitha I. Wickramaratne ◽  
Yashmitha Kavindi ◽  
Muditha Tissera ◽  
...  

10.2196/27386 ◽  
2021 ◽  
Vol 9 (12) ◽  
pp. e27386
Author(s):  
Qingyu Chen ◽  
Alex Rankine ◽  
Yifan Peng ◽  
Elaheh Aghaarabi ◽  
Zhiyong Lu

Background Semantic textual similarity (STS) measures the degree of relatedness between sentence pairs. The Open Health Natural Language Processing (OHNLP) Consortium released an expertly annotated STS data set and called for the National Natural Language Processing Clinical Challenges. This work describes our entry, an ensemble model that leverages a range of deep learning (DL) models. Our team from the National Library of Medicine obtained a Pearson correlation of 0.8967 in an official test set during 2019 National Natural Language Processing Clinical Challenges/Open Health Natural Language Processing shared task and achieved a second rank. Objective Although our models strongly correlate with manual annotations, annotator-level correlation was only moderate (weighted Cohen κ=0.60). We are cautious of the potential use of DL models in production systems and argue that it is more critical to evaluate the models in-depth, especially those with extremely high correlations. In this study, we benchmark the effectiveness and efficiency of top-ranked DL models. We quantify their robustness and inference times to validate their usefulness in real-time applications. Methods We benchmarked five DL models, which are the top-ranked systems for STS tasks: Convolutional Neural Network, BioSentVec, BioBERT, BlueBERT, and ClinicalBERT. We evaluated a random forest model as an additional baseline. For each model, we repeated the experiment 10 times, using the official training and testing sets. We reported 95% CI of the Wilcoxon rank-sum test on the average Pearson correlation (official evaluation metric) and running time. We further evaluated Spearman correlation, R², and mean squared error as additional measures. Results Using only the official training set, all models obtained highly effective results. BioSentVec and BioBERT achieved the highest average Pearson correlations (0.8497 and 0.8481, respectively). BioSentVec also had the highest results in 3 of 4 effectiveness measures, followed by BioBERT. However, their robustness to sentence pairs of different similarity levels varies significantly. A particular observation is that BERT models made the most errors (a mean squared error of over 2.5) on highly similar sentence pairs. They cannot capture highly similar sentence pairs effectively when they have different negation terms or word orders. In addition, time efficiency is dramatically different from the effectiveness results. On average, the BERT models were approximately 20 times and 50 times slower than the Convolutional Neural Network and BioSentVec models, respectively. This results in challenges for real-time applications. Conclusions Despite the excitement of further improving Pearson correlations in this data set, our results highlight that evaluations of the effectiveness and efficiency of STS models are critical. In future, we suggest more evaluations on the generalization capability and user-level testing of the models. We call for community efforts to create more biomedical and clinical STS data sets from different perspectives to reflect the multifaceted notion of sentence-relatedness.


10.2196/23230 ◽  
2021 ◽  
Vol 9 (8) ◽  
pp. e23230
Author(s):  
Pei-Fu Chen ◽  
Ssu-Ming Wang ◽  
Wei-Chih Liao ◽  
Lu-Cheng Kuo ◽  
Kuan-Chih Chen ◽  
...  

Background The International Classification of Diseases (ICD) code is widely used as the reference in medical system and billing purposes. However, classifying diseases into ICD codes still mainly relies on humans reading a large amount of written material as the basis for coding. Coding is both laborious and time-consuming. Since the conversion of ICD-9 to ICD-10, the coding task became much more complicated, and deep learning– and natural language processing–related approaches have been studied to assist disease coders. Objective This paper aims at constructing a deep learning model for ICD-10 coding, where the model is meant to automatically determine the corresponding diagnosis and procedure codes based solely on free-text medical notes to improve accuracy and reduce human effort. Methods We used diagnosis records of the National Taiwan University Hospital as resources and apply natural language processing techniques, including global vectors, word to vectors, embeddings from language models, bidirectional encoder representations from transformers, and single head attention recurrent neural network, on the deep neural network architecture to implement ICD-10 auto-coding. Besides, we introduced the attention mechanism into the classification model to extract the keywords from diagnoses and visualize the coding reference for training freshmen in ICD-10. Sixty discharge notes were randomly selected to examine the change in the F1-score and the coding time by coders before and after using our model. Results In experiments on the medical data set of National Taiwan University Hospital, our prediction results revealed F1-scores of 0.715 and 0.618 for the ICD-10 Clinical Modification code and Procedure Coding System code, respectively, with a bidirectional encoder representations from transformers embedding approach in the Gated Recurrent Unit classification model. The well-trained models were applied on the ICD-10 web service for coding and training to ICD-10 users. With this service, coders can code with the F1-score significantly increased from a median of 0.832 to 0.922 (P<.05), but not in a reduced interval. Conclusions The proposed model significantly improved the F1-score but did not decrease the time consumed in coding by disease coders.


Sign in / Sign up

Export Citation Format

Share Document