scholarly journals Um estudo sobre a avaliação de fissuras em paredes de concreto moldadas para edifícios residenciais a partir de patologias recorrentes / A study on the evaluation of cracks in concrete walls cast for residential buildings from recurrent pathologies

2021 ◽  
Vol 7 (12) ◽  
pp. 114315-114329
Author(s):  
Enoque De Jesus Soares ◽  
Antônio Estanislau Sanches ◽  
Érika Cristina Nogueira Marques Pinheiro
2013 ◽  
Vol 663 ◽  
pp. 154-158 ◽  
Author(s):  
Tae Sik Oh ◽  
Seok Joon Jang ◽  
Kang Min Lee ◽  
Hyun Do Yun

Precast concrete sandwich panels (PCSP) are often used as exterior cladding of residential buildings due to thermal efficiency. PCSP systems consist of two precast reinforced concrete walls separated by a layer of insulation and connected with connectors which penetrate the insulation layer and are anchored at two precast walls. This paper provides the pull-out test results of concrete sandwich panel (CSP) with non-shear connectors. The variables in this study were the casting direction of reinforced concrete walls and types of insulation. Test results indicated that the types of insulations and casting direction have a significant effect on the bond strength between concrete wall and insulation. The effect of insulation type is notable for CSP cast horizontally concrete walls.


2011 ◽  
Vol 4 (1) ◽  
pp. 31-48
Author(s):  
H. M. Sacht ◽  
J. A. Rossignolo ◽  
C. Bueno

This paper presents a proposal of thermal performance evaluation of a one-storey housing typology (TI24A) executed by CDHU - Companhia de Desenvolvimento Habitacional e Urbano do Estado de São Paulo, considering the use of cast-in-place monolithic panels of concrete, with different thicknesses panels (8, 10 and 12 cm) and density between 1600 and 2400 kg/m³. In this study, the specific purpose was discussing the influence of the characteristic of concrete walls on the housing thermal performance without slab. Was defined of first parameters of study (definition of the one-storey housing typology, survey about housing users behavior and cities choose) and executed computational simulation (winter and summer), for four São Paulo State cities (São Paulo, São Carlos, Santos e Presidente Prudente), with the software Arquitrop 3.0 in a one-storey housing. Was observed that in winter and summer the typologies analyzed, the panels thickness variation had more influence about results than different concrete densities. The minimum level of thermal performance (M) in winter has been granted for some cities, with exception of Santos. In summer one of São Paulo city’s typology was attended the minimum level of thermal performance in agreement with standard “NBR 15575 Residential buildings up to five storied - Performance, Part 1: General requirements”.


Author(s):  
Domenico Prisinzano ◽  
Alessandro Federici ◽  
Amalia Martelli ◽  
Chiara Martini ◽  
Roberto Moneta

2019 ◽  
pp. 27-33
Author(s):  
Aleksei K. Solovyov ◽  
Bi Guofu

The term “window” in architecture usually stands for an opening in a wall or roof for penetration of natural light, sunrays and fresh air in premises. Recently, the requirement of contact with environment is added to this condition. It is especially relevant for residential buildings where rooms are considered residential if they have windows. The energy consumption of a building depends on sizes, form and location of windows. In winter, windows cause huge heat losses, in summer, on the other hand, large heat enters a building via the windows and is required to be removed by means of air conditioning. Moreover, windows are used for penetration of natural light in premises, which assists in saving of large amounts of power for artificial illumination. This article discusses partial solving the problem of the energy efficiency of residential buildings by determining the most efficient area of windows in terms of energy spending for compensation of heat losses via windows in winter, elimination of heat penetration through them in summer and energy losses for artificial lighting throughout the year. The analysis of the results of calculation of power consumption for residential premises in conditions of monsoon climate of the Russian Far East and Northern areas of China (PRC) is provided.