scholarly journals An Optimal Over-frequency Generator Tripping Strategy for Regional Power Grid with High Penetration Level of Renewable Energy

2021 ◽  
Vol 9 (5) ◽  
pp. 1007-1017
Author(s):  
Zhihang Zhou ◽  
Libao Shi ◽  
Yixuan Chen
2021 ◽  
Vol 2076 (1) ◽  
pp. 012022
Author(s):  
Yinsheng Su ◽  
Qian Ma ◽  
Qiang Zhang ◽  
Quan Yuan ◽  
Xinlei Huang

Abstract In order to solve the problem of low accommodation rate of renewable energy in a single region, considering the output characteristics of wind power and photovoltaic, grid constraints and cross regional power exchange, an optimization model of renewable energy accommodation capacity in a cross regional power grid year is established. This paper analyzes the factors restricting the accommodation capacity of renewable energy, and determines the access scale of renewable energy units according to the characteristics of different power grid scale, load and power supply structure. And then taking the annual maximum accommodation capacity of renewable energy as the goal, the time series production simulation model is established, considering the constraints such as regional load balancing, power transmission and output of the network cable, unit output, unit optimization power ramp rate and renewable energy output. To improve the renewable energy accommodation capacity, the three factors of power system interconnection level, power regulation performance and load characteristics can be considered.


2013 ◽  
Vol 336-338 ◽  
pp. 1174-1179 ◽  
Author(s):  
Fan Yang ◽  
Yin Heng Su ◽  
Shu Qiang Zhao ◽  
Yun Ting Song ◽  
Yong Mei ◽  
...  

The frequency characteristics of islanding operation are introduced firstly. The magnitude of balance between electromagnetic power and the original motive power and the inertia of the system are the critical factors that affect the frequency. Based on the possible over-frequency problems during the isolated operation of the regional network, the configuration principles of over frequency generator tripping are proposed. Taking an actual grid as an example, an adaptable and efficient configuration solution of over frequency generator tripping is made according to the principles. In addition, the coordination between over frequency generator tripping and over-speed protection controller is studied. This paper brings forward meaningful reference configuration principles for over frequency generator tripping that is suitable to small-capacity regional power grid which is in infirm interconnections.


Sign in / Sign up

Export Citation Format

Share Document