Efficacy of Transverse Tripolar Spinal Cord Stimulator for the Relief of Chronic Low Back Pain from Failed Back Surgery

2008 ◽  
Vol 3;11 (5;3) ◽  
pp. 333-338
Author(s):  
Asokumar Buvanendran

Background: Failed back surgery syndrome is a common clinical entity for which spinal cord stimulation has been found to be an effective mode of analgesia, but with variable success rates. Objective: To determine if focal stimulation of the dorsal columns with a transverse tripolar lead might achieve deeper penetration of the electrical stimulus into the spinal cord and therefore provide greater analgesia to the back. Design: Case report. Methods: We describe a 42-year-old female with failed back surgery syndrome that had greater back pain than leg pain. The tripolar lead configuration was achieved by placing percutaneously an octapolar lead in the spinal midline followed by 2 adjacent quadripolar leads, advanced to the T7-T10 vertebral bodies. Results: Tripolar stimulation pattern resulted in more than 70% pain relief in this patient during the screening trial, while stimulation of one or 2 electrodes only provided 20% pain relief. After implantation of a permanent tripolar electrode system with a single rechargeable battery, the pain relief was maintained for one year. Conclusion: This is case report describing a case of a patient with chronic low back pain with a diagnosis of failed back surgery syndrome in which transverse tripolar stimulation using an octapolar and 2 quadripolar leads appeared to be beneficial. The transverse tripolar system consists of a central cathode surrounded by anodes, using 3 leads. This arrangement may contribute to maximum dorsal column stimulation with minimal dorsal root stimulation and provide analgesia to the lower back. Key words: Epidural, low back pain, spinal cord stimulation, failed back surgery syndrome, tripolar stimulation

2020 ◽  
Vol 0 (0) ◽  
Author(s):  
David Reehl ◽  
Thomas Cheriyan ◽  
Owais Qureshi ◽  
Zhuo Sun ◽  
Paramvir Singh ◽  
...  

AbstractObjectivesThe purpose of this case report is to describe an occurrence of a rare complication of lead extrusion, which was observed 10 months after spinal cord stimulator (SCS) implantation.MethodsA patient with low back pain and failed back surgery syndrome underwent implantation of a SCS without complications. Ten months after implantation, one SCS lead extruded from her lower back leading to surgical removal of the leads.ResultsAfter identifying the complication of a SCS lead extruding from the patient’s back, a surgical revision was performed to remove the SCS leads but retain the implantable pulse generator (IPG) in the gluteal region. During the surgery, it was noted that the anchors were in the appropriate position, sutured and fibrosed to a deep fascial layer. There were no complications from the surgical revision and no infectious process was observed.ConclusionsWe report the occurrence and management of a rare complication of SCS lead extrusion after SCS implantation for failed back surgery syndrome. After recognition, removal of the leads with retention of the IPG was able to effectively resolve the complication. The revising procedure was well tolerated but resulted in the recurrence of the patient’s previous low back pain. We believe that knowledge of this case and its management will aid future physicians in the recognition and management of this rare complication of SCS implantation. Furthermore, as there is a paucity of literature discussing the management of lead extrusion after SCS implantation, we hope that this case report will spur additional research on the management of this complication.


Author(s):  
Stefan Motov ◽  
Kaywan Aftahy ◽  
Ann-Kathrin Jörger ◽  
Arthur Wagner ◽  
Bernhard Meyer ◽  
...  

AbstractTreatment of patients with failed back surgery syndrome (FBSS) with predominant low back pain (LBP) remains challenging. High-frequency spinal cord stimulation (HF10 SCS) is believed to achieve significant pain reduction. We aimed to evaluate the real-life efficacy of HF-10 SCS in a tertiary spine center. A prospective observational study of all patients with FBSS and predominant LBP who underwent HF-10 SCS surgery was performed between 2016 and 2018. Patients > 18 years with Visual Analogue Scale (VAS) scores of ≥ 5 for LBP and pain duration > 6 months under stable medication were implanted percutaneous under general anesthesia and a trial phase of 7–14 days was accomplished. Primary end point was a successful trial defined as ≥ 50% VAS score reduction for LBP. Thirty-four of 39 (85%) subjects had a successful trial. Fifty-three percent were female and the mean age was 69 years. Median follow-up lasted for 10 months. Devices were removed after a median of 10 months in 5 cases. Remaining 29 patients stated significant VAS score reduction for LBP from 8.1 to 2.9 and VAS for leg pain from 4.9 to 2.2. Twenty-four percent of all patients were able to discontinue their opioids. Eight of 9 patients (89%) with signs of adjacent disc disease and 7 of 10 (70%) patients with hardware failure were successfully implanted with significant VAS reduction for LBP. HF-10 SCS achieves significant pain reduction in most patients with FBSS and predominant LBP. It might be an efficient alternative to revision surgery.


2017 ◽  
Vol 20 (7) ◽  
pp. 668-674 ◽  
Author(s):  
Thibault Yves Remacle ◽  
Vincent Luce Bonhomme ◽  
Henri-Jean Paul Renwart ◽  
Jean Michel Remacle

Neurosurgery ◽  
2019 ◽  
Vol 66 (Supplement_1) ◽  
Author(s):  
Erin McCormack ◽  
Mansour H Mathkour ◽  
Lora Wallis Kahn ◽  
Maged Guirguis ◽  
Gassan Chaiban ◽  
...  

Abstract INTRODUCTION Complex regional pain syndrome (CRPS) is a disabling form of constant and intense chronic pain involving a limb. Failed back surgery syndrome (FBSS) is chronic back pain following back surgery. Burst stimulation is a novel concept applied recently to treat chronic pain through spinal cord stimulation (SCS). The impulses are thought to travel to the thalamus to treat sensory, affective, and attentional components of neuropathic pain by targeting both the somatosensory cortex and the limbic system. METHODS A 50-yr-old female presented 1 yr after L5-S1 posterior instrumentation and posterolateral arthrodesis for spondylolisthesis with disabling Type I CRPS of her left foot and back pain. Postoperative improvement in back pain was noted but her left leg pain became worse despite SCS reprogramming. Two months later, she underwent placement of a different paddle lead at T12 and a new pulse generator using burst therapy. This resulted in complete resolution of foot pain. She remains pain-free 5 mo postoperatively. RESULTS Our patient underwent a T9-T10 high frequency (10 kHz) SCS trial followed by permanent paddle lead placement at T9-10 which provided more than 50% foot pain relief resulting in improved range of motion. However, worsening back pain and pseudoarthrosis mandated a revision of her prior arthrodesis 6 mo after SCS surgery. CONCLUSION In selected patients with FBSS and CRPS, revision of arthrodesis combined with SCS may be needed to achieve adequate pain relief. Burst therapy may be superior to high frequency stimulation in select patients.


Sign in / Sign up

Export Citation Format

Share Document