scholarly journals An Alternative Femoral Stem-bone Implantation Technique Using an Innovative Short Femoral Stem Endoprosthesis

2018 ◽  
Vol 69 (11) ◽  
pp. 3299-3303
Author(s):  
Marius Moga ◽  
Augustin Semenescu ◽  
Razvan Daniel Chivu ◽  
Mihnea Cosmin Costoiu ◽  
Ileana Mariana Mates ◽  
...  

Arthroplasty of the hip, for either arthritic changes or femoral neck fracture, is a common procedure in orthopedic surgery. Although the standard designs for implantation, either cemented or uncemented, are well described and studied, there are also alternative designs regarding the implantation of both prosthetic stem and cup. This paper aims to explore one such alternative design, using the screw-in technique. It has been described in past literature for uncemented fixation of both the cup and the stem, and the biomechanical principles of fixation are different from the classical methods, offering certain advantages that are insufficiently explored in current-day endoprosthesis. Also, we will be presenting an innovative femoral stem design, recently developed, that combines an uncemented screw-on technique with a cemented augmentation possibility, aimed to provide the practitioner with the advantages of a bone-preserving mini-stem design, combined with the innovative screw-in fixation technique and the versatility of the hybrid cemented/uncemented fixation method.

2016 ◽  
Vol 27 (1) ◽  
pp. 26-34 ◽  
Author(s):  
Ashleen R. Knutsen ◽  
Nicole Lau ◽  
Donald B. Longjohn ◽  
Edward Ebramzadeh ◽  
Sophia N. Sangiorgio

Introduction Periprosthetic bone loss may lead to major complications in total hip arthroplasty (THA), including loosening, migration, and even fracture. This study analysed the influence of femoral implant designs on periprosthetic bone mineral density (BMD) after THA. Methods The results of all previous published studies reporting periprosthetic femoral BMD following THA were compiled. Using these results, we compared percent changes in bone loss as a function of: femoral stem fixation, material, and geometry. Results The greatest bone loss was in the calcar region (Gruen Zone 7). Overall, cemented stems had more bone loss distally than noncemented stems, while noncemented stems had more proximal bone loss than cemented stems. Within noncemented stems, cobalt-chromium (CoCr) stems had nearly double the proximal bone loss compared to titanium (Ti) alloy stems. Finally, within noncemented titanium alloy group, straight stems had less bone loss than anatomical, tapered, and press-fit designs. Discussion The findings from the present study quantified percent changes in periprosthetic BMD as a function of fixation method, alloy, and stem design. While no one stem type was identified as ideal, we now have a clearer understanding of the influence of stem design on load transfer to the surrounding bone.


2021 ◽  
Vol 6 ◽  
pp. 247275122110192
Author(s):  
Karel Kuik ◽  
Jean Pierre T. F. Ho ◽  
Cornelis Klop ◽  
Maurits H. T. de Ruiter ◽  
Cornelis J. Kleverlaan ◽  
...  

Study Design: Biomechanical in vitro study. Mandibular advancement after sagittal split ramus osteotomy (SSRO) is a common procedure in orthognathic surgery. Several fixation methods are used for stabilization of SSRO. Objective: The aim of this study was to compare a new fixation method (gridplate) with more contemporary applied methods of fixation. Material and Methods: In this study, 50 polyurethane hemimandibles with a prefabricated SSRO were used as specimens. All hemimandibles were advanced by 8 mm and divided into 5 groups with different fixation methods: (A) one 4-hole miniplate with 4 monocortical screws; (B) two 4-hole miniplates with 8 monocortical screws; (C) one 4-hole miniplate with 4 monocortical screws and 1 bicortical screw in the retromolar area (hybrid method); (D) 3 bicortical screws in an inverted-L pattern; and (E) one 8-hole gridplate with 8 monocortical screws. Loads in newtons were recorded at displacements of the mandibular incisive edge at 1 mm, 3 mm and 5 mm. Results: Fixation with 3 bicortical screws and the gridplate presented the most stability, followed by two 4-hole miniplates. Fixation with the hybrid method or the single miniplate showed the least stability. Conclusion: According to the results of this study, the 8-hole gridplate design appears a sufficient fixation method regarding stabilization of SSRO with larger mandibular advancement.


2016 ◽  
Vol 13 (4) ◽  
pp. 322-326 ◽  
Author(s):  
Munnan Al-Najjim ◽  
Usman Khattak ◽  
Juluis Sim ◽  
Iain Chambers

2016 ◽  
Vol 24 (3) ◽  
pp. 323-327 ◽  
Author(s):  
Rajesh Malhotra ◽  
Vijay Kumar

Purpose To review the outcome of total hip arthroplasty (THA) using a short femoral stem in 33 hips. Methods Records of 33 hips in 20 men and 10 women aged 25 to 40 (mean, 30) years who underwent cementless THA using a short femoral stem by a single senior surgeon were reviewed. The diagnosis included avascular necrosis (n=9), ankylosing spondylitis (n=12), rheumatoid arthritis (n=7), post-traumatic arthritis (n=4), and Hurler syndrome (n=1). Clinical outcome was assessed using the Harris Hip Score. Radiological outcome was assessed according to a modified Gruen zoning system. Stem positioning (neutral, varus, valgus) and bone contact were evaluated, as were fixation and early host response as well as subsidence and changes in the calcar region (zone 5). Trabecular response (trabecular attachment), spot welds, cortical hypertrophy, and pedestal formation were determined. Heterotopic ossification was graded by the Brooker classification. Results The mean follow-up period was 6.5 years. The mean Harris Hip Score improved from 40 to 90. All hips achieved immediate postoperative stability. No patient had thigh pain. Four hips had varus placement (5°–7°) of the stem; all were asymptomatic and remained stable without any migration. Evidence of proximal load transfer (endosteal spot welds) between the endosteum and the stem in zones 2 and/or 4 was noted in 12 hips on both sides and in 8 hips on the lateral side only. At one year, all stems showed evidence of osseointegration. None had subsidence or progressive varus migration. There was no radiolucent line or osteolysis around the stem, pedestal formation or buttressing at the prosthesis tip, or cortical hypertrophy. One patient had grade I heterotopic ossification that was not clinically significant. One patient had a 1.5 cm leg lengthening. One patient had a discharging sinus, a loosened acetabular component, and intrapelvic migration at 2 years and underwent implant removal and debridement. One patient developed a crack in the proximal femur even with the smallest stem. The stem was fixed with cerclage wiring and remained stable with no migration. Conclusion A short femoral stem design that transfers load proximally through a prominent lateral flare achieved good short-term outcome in younger patients. Nonetheless, the ease of removal and preservation of bone at the time of revision should guide the choice of the design of the short stem.


1997 ◽  
Vol 7 (3) ◽  
pp. 125-127
Author(s):  
J. Cordes ◽  
K. Sperling ◽  
M. Kramhøft

In the literature, only one case of displacement of a cemented femoral stem from its cement bed during closed reduction of a dislocation has been reported. In that case, it was suggested that the stem design may in part be the explanation for the displacement. Another case with a cemented Müller straight stem is now presented, emphasizing the use of image intensification if reduction proves difficult.


Sign in / Sign up

Export Citation Format

Share Document