Varus malalignment of short femoral stem not associated with post-hip arthroplasty fracture

Author(s):  
Scott T. Nishioka ◽  
Samantha N. Andrews ◽  
Kristin Mathews ◽  
Cass K. Nakasone
2016 ◽  
Vol 24 (3) ◽  
pp. 323-327 ◽  
Author(s):  
Rajesh Malhotra ◽  
Vijay Kumar

Purpose To review the outcome of total hip arthroplasty (THA) using a short femoral stem in 33 hips. Methods Records of 33 hips in 20 men and 10 women aged 25 to 40 (mean, 30) years who underwent cementless THA using a short femoral stem by a single senior surgeon were reviewed. The diagnosis included avascular necrosis (n=9), ankylosing spondylitis (n=12), rheumatoid arthritis (n=7), post-traumatic arthritis (n=4), and Hurler syndrome (n=1). Clinical outcome was assessed using the Harris Hip Score. Radiological outcome was assessed according to a modified Gruen zoning system. Stem positioning (neutral, varus, valgus) and bone contact were evaluated, as were fixation and early host response as well as subsidence and changes in the calcar region (zone 5). Trabecular response (trabecular attachment), spot welds, cortical hypertrophy, and pedestal formation were determined. Heterotopic ossification was graded by the Brooker classification. Results The mean follow-up period was 6.5 years. The mean Harris Hip Score improved from 40 to 90. All hips achieved immediate postoperative stability. No patient had thigh pain. Four hips had varus placement (5°–7°) of the stem; all were asymptomatic and remained stable without any migration. Evidence of proximal load transfer (endosteal spot welds) between the endosteum and the stem in zones 2 and/or 4 was noted in 12 hips on both sides and in 8 hips on the lateral side only. At one year, all stems showed evidence of osseointegration. None had subsidence or progressive varus migration. There was no radiolucent line or osteolysis around the stem, pedestal formation or buttressing at the prosthesis tip, or cortical hypertrophy. One patient had grade I heterotopic ossification that was not clinically significant. One patient had a 1.5 cm leg lengthening. One patient had a discharging sinus, a loosened acetabular component, and intrapelvic migration at 2 years and underwent implant removal and debridement. One patient developed a crack in the proximal femur even with the smallest stem. The stem was fixed with cerclage wiring and remained stable with no migration. Conclusion A short femoral stem design that transfers load proximally through a prominent lateral flare achieved good short-term outcome in younger patients. Nonetheless, the ease of removal and preservation of bone at the time of revision should guide the choice of the design of the short stem.


2020 ◽  
Vol 04 (01) ◽  
pp. 033-037
Author(s):  
Samantha Andrews ◽  
Gregory J. Harbison ◽  
Ian Hasegawa ◽  
Emily Unebasami ◽  
Cass Nakasone

AbstractThe cementless, tapered wedge, short femoral stem implant is commonly used in direct anterior approach (DAA) total hip arthroplasty (THA). The lack of access and visualization, however, may increase the risk of perioperative fracture and early failure. Therefore, the current study examined perioperative complications and 2-year implant survivorship following DAA THA performed using a fracture table and short, tapered wedge femoral stem. A retrospective analysis was conducted on patients having undergone DAA THA with a cementless, tapered wedge, short femoral stem. Perioperative fractures were noted and survivorship was determined by the incidence of revision surgery within a minimum 2-year follow-up period. A total 366 consecutive patients (441 hips) were identified in the cohort. Four patients (6 hips; 1.4%) were lost to follow-up and three patients died from unrelated causes. Average follow-up time for the remaining 359 patients (435 hips) was 32.9 ± 10.2 months. There were no intraoperative factures but three perioperative fractures within two weeks. Aseptic loosening occurred in one stem at 13 months, resulting in a 99.1% survival rate with a mean survival time of 23.8 ± 0.1 months (95% confidence interval: 23.6–24.0 months). The use of a short, tapered wedge femoral stem and a fracture table for DAA THA resulted in 0.7% periprosthetic fractures and only one aseptic loosening within 2 years. These results suggest that proper femoral exposure with the use of a fracture table and a short, tapered wedge femoral stem does not appear to increase the risk of periprosthetic femoral fracture.


Author(s):  
Malynda S. Wynn ◽  
Christopher N. Carender ◽  
Emily Solsrud ◽  
Charles R. Clark ◽  
Jesse E. Otero ◽  
...  

2017 ◽  
Vol 27 (4) ◽  
pp. 311-316 ◽  
Author(s):  
Jaime J. Morales de Cano ◽  
Christian Gordo ◽  
Jordi Canosa Areste

Background We present the result of our experience in using a short femoral stem in elderly patients (>70 years of age) compared to patients younger than 70 years. Methods Data were prospectively collected on 138 patients who underwent 148 primary total hip arthroplasty (THA), with a conservative short stem between November 2010 and June 2014. The cohort was divided into 2 groups: the study group (group 1) comprised 57 patients (60 THA) over 70 years of age at the time of surgery, with a mean age of 75.4 years (range 70-87 years) and a mean follow-up of 26.7 months (range 9-48 months). The control group (group 2) comprised 81patients (88 THA) less than 70 years of age with a mean age of 57.4 years (range 33-69 years) and a mean follow-up of 27.3 months (range 9-54 months). Hip function in the 2 groups was compared preoperatively and postoperatively using the Merle D'Aubigne hip score (MD) and Western Ontario and McMaster Universities Arthritis Index (WOMAC) score. Results At the latest follow-up, 1 calcar fracture was reported in a 54-year-old patient in the control group, which required fixation with a screw and had a favourable outcome. No cases of clinical or radiographic loosening were reported. Clinical results showed no statistically significant differences between the 2 groups. Conclusions The use of the GTS conservative short stem in patients over 70 years old has shown very good results and low complication rates, comparable to those for patients younger than 70 years.


2019 ◽  
Vol 2019 ◽  
pp. 1-7 ◽  
Author(s):  
Y. Knafo ◽  
F. Houfani ◽  
B. Zaharia ◽  
F. Egrise ◽  
I. Clerc-Urmès ◽  
...  

Two-dimensional (2D) planning on standard radiographs for total hip arthroplasty may not be sufficiently accurate to predict implant sizing or restore leg length and femoral offset, whereas 3D planning avoids magnification and projection errors. Furthermore, weightbearing measures are not available with computed tomography (CT) and leg length and offset are rarely checked postoperatively using any imaging modality. Navigation can usually achieve a surgical plan precisely, but the choice of that plan remains key, which is best guided by preoperative planning. The study objectives were therefore to (1) evaluate the accuracy of stem/cup size prediction using dedicated 3D planning software based on biplanar radiographic imaging under weightbearing and (2) compare the preplanned leg length and femoral offset with the postoperative result. This single-centre, single-surgeon prospective study consisted of a cohort of 33 patients operated on over 24 months. The routine clinical workflow consisted of preoperative biplanar weightbearing imaging, 3D surgical planning, navigated surgery to execute the plan, and postoperative biplanar imaging to verify the radiological outcomes in 3D weightbearing. 3D planning was performed with the dedicated hipEOS® planning software to determine stem and cup size and position, plus 3D anatomical and functional parameters, in particular variations in leg length and femoral offset. Component size planning accuracy was 94% (31/33) within one size for the femoral stem and 100% (33/33) within one size for the acetabular cup. There were no significant differences between planned versus implanted femoral stem size or planned versus measured changes in leg length or offset. Cup size did differ significantly, tending towards implanting one size larger when there was a difference. Biplanar radiographs plus hipEOS planning software showed good reliability for predicting implant size, leg length, and femoral offset and postoperatively provided a check on the navigated surgery. Compared to previous studies, the predictive results were better than 2D planning on conventional radiography and equal to 3D planning on CT images, with lower radiation dose, and in the weightbearing position.


Author(s):  
Ahmed K. Emara ◽  
Mitchell Ng ◽  
Viktor E. Krebs ◽  
Michael Bloomfield ◽  
Robert M. Molloy ◽  
...  

Author(s):  
Anatole Vilhelm Wiik ◽  
Adeel Aqil ◽  
Bilal Al-Obaidi ◽  
Mads Brevadt ◽  
Justin Peter Cobb

Abstract Aim The length of the femoral stem in total hip arthroplasty (THA) is a practical consideration to prevent gait impairment. The aim of this study was to determine if reducing the femoral stem length in THA would lead to impaired gait biomechanics. Methods Patients uniformly with the same brand implant of differing lengths (100 mm vs 140–166 mm) were taken retrospectively from a prospective trial introducing a new short stem. Twelve patients without any other disorder to alter gait besides contralateral differing length stem THA were tested at differing gradients and speed on a validated instrumented treadmill measuring ground reaction forces. An anthropometrically similar group of healthy controls were analysed to compare. Results With the same posterior surgical approach, the offset and length of both hips were reconstructed within 5 mm of each other with an identical mean head size of 36 mm. The short stem was the last procedure for all the hips with gait analysis occurring at a mean of 31 and 79 months postoperatively for the short and long stem THA, respectively. Gait analysis between limbs of both stem lengths demonstrated no statistical difference during any walking condition. In the 90 gait assessments with three loading variables, the short stem was the favoured side 51% of the time compared 49% for the long stem. Conclusion By testing a range of practical walking activities, no lower limb loading differences can be observed by reducing the femoral stem length. A shorter stem demonstrates equivalence in preference during gait when compared to a reputable conventional stem in total hip arthroplasty.


Sign in / Sign up

Export Citation Format

Share Document