Thermodynamic Analysis of R134a-R23 Cascade Refrigeration System

2015 ◽  
Vol 787 ◽  
pp. 117-123
Author(s):  
P.L. Rupesh ◽  
J.M. Babu ◽  
R. Mariappan

The present work deals with thermodynamic analysis of a R-134a/R-23 cascade refrigeration system to evaluate the maximum COP and the minimum temperature difference (DT) corresponding to , by considering different operating parameters. The operating parameters includes: the condensing () and evaporating temperature () of R-134a and the condensing () and evaporating temperature () of R-23. A computational model has been developed for the considered system to evaluate the and DT corresponding to based on the thermodynamic principles. A mutilinear regression analysis has been carried out to evaluate two correlations for calculating and minimum DT considering the above operating parameters. The exergy analysis of the system is also performed to determine the irreversibility losses of the system as well as for the components. It has been found that the total exergy destruction rate of the system is lower at minimum .

Author(s):  
Hendri ◽  
Roswati Nurhasanah ◽  
Prayudi ◽  
Suhengki

Low temperature storage with a single refrigeration system only stable up to 228 K temperature. The purpose of this study is to develop a low temperature cool storage with cascade refrigeration system, with hydrocarbon refrigerants in terms of energy and exergy analysis. Experimental research in laboratories using refrigerant hydrocarbon MC22 and MC134 on the hight temperature circuit, and R404A and R502 using on low temperature circuit. Condenser heat exchanger using a type of exchanger plate. Resulting from this research, obtained that result the MC22/R404A, MC22/R502 and MC134/R404A refrigerant pair can reach a temperature of 220 K. The MC22/R404A refrigerant pair has god performance, COP, total loss exergy, and exergy efficiency is better than MC22/R502, and MC134/R04A refrigerant pairs.


This paper gives a detailed exergy analysis of a Vapour Compression Refrigeration System with the refrigerants R-134a and HC (mixture of R-290/R-600a). The aim of this paper is to find out the Exergy Analysis, Exergetic efficiency, Exergy Product, Exergy Destruction Ratio (EDR), Co-efficient of performance and 2nd law efficiency for the main components of the system such as compressor, condenser, evaporator and expansion device (throttle valve). The objective of this work is to find out an exergy analysis of the Hydrocarbon refrigerant as an alternative for R-134a. The VCRS performance using R134a will be evaluated for the effect of evaporating temperature on COP, exergetic efficiency and EDR and then compared with Hydrocarbon refrigerant. Due to prevention of GWP (Global Warming Potential), Hydrocarbon and R-134a are used as refrigerants to give better result for domestic refrigerator operation[8] .


Sign in / Sign up

Export Citation Format

Share Document