cascade refrigeration system
Recently Published Documents


TOTAL DOCUMENTS

159
(FIVE YEARS 58)

H-INDEX

22
(FIVE YEARS 6)

Author(s):  
Adam RUCIŃSKI ◽  
Mateusz DALBA ◽  
Rafał LASKOWSKI

The paper treats with refrigerants which affect on excessive heating of atmosphere. They are in group offluorinated greenhouse gases which are regulated by European and polish law. The main aim is to lower their amount in industry leading to overall removal from use. We present possible way to design refrigeration system lowering their adverse effect on natural environment. So three options of cooling systems are analyzed: one-stage refrigeration system working with R449A, cascade refrigeration system with R744 (carbon dioxide)/ R134a and R717 (ammonia) refrigeration plant. Due to the nowadays raising use of the cascade systems, an analysis of the operating parameters of such installation was carried out with considering the cascade heat exchanger as a condenser/evaporator. The installations concerned are three alternative offers for meat processing manufactory. A thermal balance was prepared for chambers located in building and the operating parameters of the installation were assumed. The equipment corresponding to the required cooling capacities were selected.


2021 ◽  
Vol 9 (6) ◽  
pp. 106473
Author(s):  
Mahdi Deymi-Dashtebayaz ◽  
Alexander Sulin ◽  
Tatyana Ryabova ◽  
Iuliia Sankina ◽  
Mehdi Farahnak ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (18) ◽  
pp. 6003
Author(s):  
Min-Ju Jeon

This study evaluates the performance of an R744/R404A cascade refrigeration system (CRS) with internal heat exchangers (IHE) in supermarkets. R744 is used as the refrigerant in a low-temperature cycle, and R404A is used as the refrigerant in a high-temperature cycle. In previous studies, there are many studies including theoretical performance analysis of the CRS. However, experimental studies on the CRS are lacking, and experimental research on the R744/R404A system with an IHE is scarce. Therefore, this study provides basic data for optimal refrigeration system design by experimentally evaluating the results of modifying various parameters. The operating parameters considered in this study include subcooling and superheating, condensing and evaporating temperature, cascade evaporation temperature, and IHE efficiency in the R744 low- and R404A high-temperature cycle. The main results are summarized as follows: (1) By applying the results of this study, energy efficiency is achieved by optimizing the overall coefficient of performance (COP) of the CRS, and the refrigerant charge of the R404A cycle is minimized and economic efficiency is also obtained, enabling operation and maintenance as an environment-friendly system. (2) When designing the CRS, finding the cascade evaporation temperature that has the optimum and maximum COP according to the refrigerant combination should be considered with the highest priority.


Author(s):  
Cleison Henrique de Paula ◽  
Willian Moreira Duarte ◽  
Thiago Torres Martins Rocha ◽  
Raphael Nunes de Oliveira ◽  
Antônio Augusto Torres Maia

In this work, a cascade refrigeration system operating with four different ecological refrigerant pairs was modeled. This system uses R744 (Carbon dioxide) in the low-temperature cycle and operates with R290 (propane), R1234yf (2,3,3,3-tetrafluoropropene), R152a (1,1-difluorethane), and R717 (ammonia) in the high-temperature cycle. Energetic, exergetic, environmental, and economic performance of the cascade system was investigated to determine the most appropriate ecological refrigerant couple. The parameters used in each mentioned performance were COP (Coefficient of Performance), [Formula: see text] (Exergy Efficiency), TEWI (Total Equivalent Warming Impact), ECOP (Ecological coefficient of performance), and [Formula: see text] (Total plant cost rate), respectively. The results showed that the cascade refrigeration system operating with R744/R717 provided the best performance for the thermodynamic conditions analyzed, presenting a COP of 2.10, [Formula: see text] of 56.9%, [Formula: see text] of 24 334 USD/year, ECOP of 4.86, and TEWI of 25.67 tons of CO2. Finally, evaluating the total plant cost rate of this cascade system, it was noted that the capital and maintenance cost rate [Formula: see text] corresponds to 89.1% of the [Formula: see text] value, the operational cost rate [Formula: see text] corresponds to 10.27% of the [Formula: see text] value and the environmental cost rate [Formula: see text] corresponds to 0.63% of [Formula: see text].


2021 ◽  
Vol 20 (2) ◽  
pp. 20
Author(s):  
V. B. Rangel ◽  
A. G. S. Almeida

Cascade refrigeration systems work with two or more serial disposed cycles and can obtain internal temperatures below -60°C, which is necessary for several activities in medicine and scientific research. This paper presents a thermodynamic analysis of cascade system refrigeration using natural refrigerant fluids for ultra-low temperatures. These fluids are environmentally friendly refrigerant and are an alternative to hydro chlorofluorocarbons (HCFCs) and to hydrofluorocarbons (HFCs). Energy and exergy analyses were performed using a thermodynamic model based on the law of conservation of mass and also on the first and second laws of thermodynamics. A simulator was developed to assess the technical practicability of this system, considering it running as a real refrigeration cycle. Natural fluids have best performance energetically and environmentally.