The Seismic Dynamic Response on the Steel Spatial Arch Truss with 60 m Span and 0.4 Rise-Span Ratio

2011 ◽  
Vol 368-373 ◽  
pp. 850-853
Author(s):  
Hai Wang Li ◽  
Jing Jing Guo ◽  
Jing Liu

In this paper, the elasto-plastic dynamic analysis on the steel spatial arch truss with 60 m span and 0.4 rise-span ratio is carried out under earthquake wave with SAP2000. In the analyses, the geometric and material nonlinear effects are considered at the same time based on the plastic-hinge theory. Under the action of EL wave with the peak increasing gradually, its elasto-plastic dynamic responses have been obtained. The results show that its failure mode under the earthquake action is elasto-plastic dynamic buckling; that its critical peak acceleration of EL earthquake wave when applied in horizontal direction is 808.5 gal, and is 789.0 gal when applied in vertical direction; The ratio of its maximal node horizontal displacement and its structural height is 1/259, and its displacement ductility coefficient is 1.071; The ratio of its maximal node vertical displacement and its structural span is 1/736, and its displacement ductility coefficient is 1.105.

2011 ◽  
Vol 105-107 ◽  
pp. 1620-1623
Author(s):  
Hai Wang Li ◽  
Zhi Wei Wang ◽  
Jin Liu

Abstract. In this paper, the elasto-plastic dynamic analysis on the steel spatial arch truss with 30 m span and 0.1 rise-span ratio is carried out under earthquake wave with SAP2000. In the analyses, the geometric and material nonlinear effects are considered at the same time based on the plastic-hinge theory. Under the action of EL wave with the peak increasing gradually, its elasto-plastic dynamic responses have been obtained. The results show that its failure mode under the earthquake action is elasto-plastic dynamic buckling; that its critical peak acceleration of EL earthquake wave when applied in horizontal direction is 517 gal, and is 387 gal when applied in vertical direction; The ratio of its maximal node horizontal displacement and its structural height is 1/96, and its displacement ductility coefficient is 2.636; The ratio of its maximal node vertical displacement and its structural span is 1/589, and its displacement ductility coefficient is 1.08.


2011 ◽  
Vol 130-134 ◽  
pp. 1101-1104
Author(s):  
Hai Wang Li ◽  
Yi Shi ◽  
Jing Liu

In this paper, the elasto-plastic dynamic analysis on the steel spatial arch truss with 30m span and 0.2 rise-span ratio is carried out under earthquake action with SAP2000. In the analyses, the geometric and material nonlinear effects are considered at the same time based on the plastic-hinge theory. Under the action of EL wave with the peak increasing gradually, its elasto-plastic dynamic responses have been obtained. The results show that its failure mode under the earthquake action is elasto-plastic dynamic buckling; that its critical peak acceleration of EL earthquake wave when applied in X direction is 654gal, and is 1108gal when applied in Z direction; The ratio of its maximal node horizontal displacement and its structural height is 1/102, and its displacement ductility coefficient is 4.215 and the ratio of its bars with plastic hinge appearing when buckling is 15.54% when EL-Centro waves applied on structure in X direction; The ratio of its maximal node vertical displacement and its structural span is 1/994, and its displacement ductility coefficient is 1.338 and the ratio of its bars with plastic hinge appearing when buckling is 11.66% when EL-Centro waves applied in Z direction.


2011 ◽  
Vol 94-96 ◽  
pp. 127-130
Author(s):  
Hai Wang Li ◽  
Lu Jiang ◽  
Jing Liu

In this paper, the elasto-plastic dynamic analysis on the steel spatial arch truss with 90 m span and 0.3 rise-span ratio is carried out under earthquake wave with SAP2000. the geometric and material nonlinear effects are considered during the analysis simultaneously based on the plastic hinge theory. Under the action of EL wave with the peak increasing gradually, its elasto-plastic dynamic responses have been obtained. The results show that its failure mode under the earthquake action is elasto-plastic dynamic buckling; that its critical peak acceleration of EL earthquake wave when applied in horizontal direction is 363 gal, and is 408 gal when applied in vertical direction; The ratio of its maximal node horizontal displacement and its structural height is 1/796, and its displacement ductility coefficient is 1.06 and the ratio of its bars with plastic hinge appearing when buckling is 0.96% when EL-Centro waves applied on structure in horizontal direction; The ratio of its maximal node vertical displacement and its structural span is 1/1418, and its displacement ductility coefficient is1.12 and the ratio of its bars with plastic hinge appearing when buckling is 1.28% when EL-Centro waves applied in vertical direction.


2011 ◽  
Vol 94-96 ◽  
pp. 201-204
Author(s):  
Hai Wang Li ◽  
Guo Juan Li ◽  
Jing Liu

The elasto-plastic dynamic response on the steel-pipe arch truss with 120 m span and 0.2 rise-span ratio is analyzed in this paper under earthquake wave with SAP2000, the geometric and material nonlinear effects are considered during the analysis simultaneously based on the plastic hinge theory. Under the action of EL-Centro waves with the peak increasing gradually, its elasto-plastic dynamic responses have been obtained. The results show that its failure mode under the earthquake action is elasto-plastic dynamic buckling; that its critical peak acceleration of EL-Centro waves when applied in horizontal direction is 644 gal and is 375 gal when applied in vertical direction; The ratio of its maximal node horizontal displacement and its rise-height is 1/538, and its displacement ductility coefficient is 1.3 and the ratio of its bars with plastic hinge appearing when buckling is 3.28% when EL-Centro waves applied on structure in horizontal direction; The ratio of its maximal node vertical displacement and its structural rise-height is 1/1136, and its displacement ductility coefficient is 1.03 and the ratio of its bars with plastic hinge appearing when buckling is 1.5% when EL-Centro waves applied in vertical direction.


2011 ◽  
Vol 105-107 ◽  
pp. 1764-1767
Author(s):  
Hai Wang Li ◽  
Xun Zhang ◽  
Jing Liu

Abstract. In this paper, the elasto-plastic dynamic analysis on the steel spatial arch truss with 90m span and 0.1rise-span ratio is carried out under earthquake wave with SAP2000. In the analyses, the geometric and material nonlinear effects are considered simultaneously based on the plastic-hinge theory. Under the action of EL-centro wave with the peak increasing gradually, its elasto-plastic dynamic responses have been obtained. The results show that its failure mode under the earthquake action is elasto-plastic dynamic buckling; that its critical peak acceleration of EL earthquake wave when applied in X direction is 635gal, and is 465gal when applied in Z direction; The ratio of its maximal node horizontal displacement and its rise height is 1/486, and its displacement ductility coefficient is 1.029 and the ratio of its bars with plastic hinge appearing when buckling is 0.7% when EL-Centro waves applied on structure in X direction; The ratio of its maximal node vertical and its structural span is 1/604, and its displacement ductility coefficient is 1.022 and the ratio of its bars with plastic hinge appearing when buckling is 2.8% when EL-Centro waves applied in Z direction.


2011 ◽  
Vol 94-96 ◽  
pp. 539-542
Author(s):  
Hai Wang Li ◽  
Wei Guo ◽  
Jing Liu

In this paper, the elasto-plastic dynamic analysis on the steel spatial arch truss with 90m span and 0.2 rise-span ratio is carried out under earthquake wave with SAP2000. In the analyses, the geometric and material nonlinear effects are considered simultaneously based on the plastic-hinge theory. Under the action of EL-centro wave with the peak increasing gradually, its elasto-plastic dynamic responses have been obtained. The results show that its failure mode under the earthquake action is elasto-plastic dynamic buckling; that its critical peak acceleration of EL earthquake wave when applied in X direction is 550gal, and is 675gal when applied in Z direction; The ratio of its maximal node horizontal displacement and its rise height is 1/635, and its displacement ductility coefficient is 1.262 and the ratio of its bars with plastic hinge appearing when buckling is 2.45% when EL-Centro waves applied on structure in X direction; The ratio of its maximal node vertical and its structural span is 1/99, and its displacement ductility coefficient is 19.207 and the ratio of its bars with plastic hinge appearing when buckling is 9.18% when EL-Centro waves applied in Z direction.


2011 ◽  
Vol 368-373 ◽  
pp. 2295-2298
Author(s):  
Hai Wang Li ◽  
Kai Li ◽  
Jing Liu

In this paper, the elasto-plastic dynamic analysis on the steel spatial arch truss with 60m span and 0.1 rise-span ratio is carried out under earthquake wave with SAP2000. In the analyses, the geometric and material nonlinear effects are considered at the same time based on the plastic-hinge theory. Under the action of EL wave with the peak increasing gradually, its elasto-plastic dynamic responses have been obtained. The results show that its failure mode under the earthquake action is elasto-plastic dynamic buckling; that its critical peak acceleration of EL earthquake wave when applied in horizontally direction is 678gal, and is 624gal when applied in vertically direction; The ratio of its maximal node horizontal and its structural height is 1/961, and its displacement ductility coefficient is 1.14 and the ratio of its bars with plastic hinge appearing when buckling is 2.15% when EL-Centro waves applied on structure in X direction; The ratio of its maximal node vertical and its structural span is 1/660, and its displacement ductility coefficient is 1.17 and the ratio of its bars with plastic hinge appearing when buckling is 6.09% when EL-Centro waves applied in Z direction.


2011 ◽  
Vol 94-96 ◽  
pp. 736-739
Author(s):  
Hai Wang Li ◽  
Wei Ping Sun ◽  
Jing Liu

In this paper, the elasto-plastic dynamic analysis on the steel spatial arch truss with 90m span and 0.4 rise-span ratio is carried out under earthquake EL-Centro wave with SAP2000. In the analyses, the geometric and material nonlinear effects are considered at the same time based on the plastic-hinge theory. Under the action of EL wave with the peak increasing gradually, its elasto-plastic dynamic responses have been obtained. All the results displays its failure mode under the earthquake action is elasto-plastic dynamic buckling; that its critical peak acceleration of EL earthquake wave when applied in X direction is 381gal, and is 583gal when applied in Z direction; The ratio of its maximal node horizontal and its structural height is 1/290, and its displacement ductility coefficient is 1.43 and the ratio of its bars with plastic hinge appearing when buckling is 3.00% when EL-Centro waves applied on structure in X direction; The ratio of its maximal node vertical and its structural span is 1/567, and its displacement ductility coefficient is 1.48 and the ratio of its bars with plastic hinge appearing when buckling is 2.50% when EL-Centro waves applied in Z direction.


2013 ◽  
Vol 275-277 ◽  
pp. 1272-1275
Author(s):  
Yun Jing Niu ◽  
Hai Wang Li ◽  
Jing Liu

In this paper, the elasto-plastic dynamic analysis on dynamic failure behaviors of steel double-layer grids supported by tridimensional truss columns used in a gymnasium with the function of earthquake victims shelter under disaster earthquake is carried out under EL-centro wave with SAP2000, and the appraisal results on their anti-failure performances are presented under strong earthquake action based on the plastic-hinge theory. In the analyses, the geometric and material nonlinear effects are considered simultaneously based on the plastic-hinge theory. The plastic development level of the rod, the deformed shape and the failure type and the ductility are estimated by plastic hinge principle. The results show that the failure model of the structure under the earthquake wave action is the complicated combination of strength failure and elasto-plastic dynamic local buckling in deferent areas of the structure; When the structure reached its failure critical limit, the development of the plastic hinges is not sufficient and only 5.11% of the rods enter into their plastic stage; Its critical failure peak acceleration of EL earthquake wave when applied in the combination of three directions is 705gal and can be served as earthquake victims shelter in the area of 8 degree seismic fortification; Its displacement ductility coefficient is 2.39,which shows the structure owns good energy dissipation capacity.


2012 ◽  
Vol 256-259 ◽  
pp. 896-900
Author(s):  
Yan Mei Zhang ◽  
Hai Wang Li ◽  
Jing Liu

The study was carried out under El-Centro wave with SAP2000, and the appraisal results on their anti-failure performances were presented under strong earthquake action based on theplastic-hinge theory. In the analyses, the geometric and material nonlinear effects were considered simultaneously. The plastic development level of the rods, the deformed shape and the failure type and the ductility were estimated by plastic hinge principle. The results show that the failure model of the structure under the earthquake wave action is the complicated combination of strength failure and elasto-plastic dynamic local buckling in deferent areas; When the structure reached its failure critical limit, only 14% of the rods enter into their plastic stage and the development of the plastic hinges is not sufficient; Its critical failure peak acceleration of EL earthquake wave when applied in the combination of three directions is 969gal, which is equivalent 2.425 times to the official seismic fortification level of 8 degree (major earthquake, 0.4g) and it can be served as earthquake victims shelter in the area of 8 degree seismic fortification; Its displacement ductility coefficient is 2.88, which shows the structure owns some energy dissipation capacity.


Sign in / Sign up

Export Citation Format

Share Document