Case Study on Sewage Treatment Measures of Technical Reform Project in a Company
This paper analyzed various water pollutants, their emissions and emissions concentration depending on the Environmental Impact Assessment (EIA) of Technical reform in an electrical company. It evaluated the capacity of implementing technical reform in this company’s wastewater treatment station and the feasibility of stability up to the discharge standard in order to find the reason Ni, one of the first class of pollutants, which was discharged by the outlets of plating factory sewage treatment facilities exceeded the standard in GB8978-1996 “Integrated Wastewater Discharge Standard”. In addition, this paper proposed a reasonable treatment program which made the drainage of the wastewater treatment station reaching the standard requirements. From this paper, it reflected the important role the environmental impact assessment played to provide a technical guidance for environmental management in the technical reform project.