Research on Application of Suction Bucket Foundation for Transmission Tower in River Network Area

2014 ◽  
Vol 919-921 ◽  
pp. 727-730 ◽  
Author(s):  
Li Qin ◽  
Jin Xin Zhu ◽  
Si Wen Zhao

Because the suction bucket foundation is construction period and low cost advantages,application of suction bucket foundation is more and more widely. In this paper, whether the suction bucket foundation can be used as the basis of transmission tower in river area were studied.According to the working mechanism of bucket foundation in soft clay ground and characteristics, through ABAQUS finite element simulation, bearing capacity under the pressure and uplift ultimate draw suction bucket foundation, and compare with the experimental results, verify the feasibility and accuracy of simulation.According to the transmission requirements of bearing capacity of the foundations,design the basic size,and verify whether the requirements of bearing capacity of foundation, confirmed the suction bucket foundation can be applied to the area of river network transmission tower.

1992 ◽  
Vol 7 ◽  
pp. 1-9 ◽  
Author(s):  
Kazutoshi Hirao ◽  
Kazuya Yasuhara ◽  
Yoshihiko Tanabashi ◽  
Kyozo Takaoka ◽  
Jun Nishimura

Géotechnique ◽  
1997 ◽  
Vol 47 (2) ◽  
pp. 339-345 ◽  
Author(s):  
M. J. Kenny ◽  
K. Z. Andrawes

2014 ◽  
Vol 513-517 ◽  
pp. 269-272
Author(s):  
Yeong Mog Park ◽  
Ik Joo Um ◽  
Norihiko Miura ◽  
Seung Cheol Baek

The purpose of this study is to investigate the undrain shear strength increment during consolidation process of soft clayey soils. Thirty kinds of laboratory triaxial tests have been performed using undisturbed and remolded Ariake clay samples with different degree of consolidation and 5 kinds of confining pressure. Test results show that well known linear equation proposed by Yamanouchi et al.(1982) is overestimated the strength of undisturbed soft clay ground in the process of consolidation. A new simple and reasonable exponential equation proposed in this paper.


2014 ◽  
Vol 915-916 ◽  
pp. 146-149
Author(s):  
Yong Sheng Wang ◽  
Li Hua Wu

The finite element model of the space KX-Joint was established using ANSYS software, and the failure mode and ultimate bearing capacity of KX-joint were researched. Calculation results show that the surface of chord wall on the roots of compression web members was into the plastic in K plane, and the holding pole without the plastic area and the local buckling failure happened in the surface of chord wall on the roots of Compression Web Members in X plane; The bearing capacity of the joint increased with the Chord diameter, which was appears in the form of power function.


2012 ◽  
pp. 833-838
Author(s):  
Z Zhang ◽  
Y Ye ◽  
H Meng ◽  
N Yang ◽  
Z Deng ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document