Simulation of the Affected Wind Power Transient Stability by Means of SVC and STATCOM

2014 ◽  
Vol 953-954 ◽  
pp. 375-379
Author(s):  
Zhi Jie Wang ◽  
San Ming Liu ◽  
Xia Sun ◽  
Xin Xia Su ◽  
Li Juan Chen ◽  
...  

In the paper the models of IG and DFIG have been analyzed, and then the two reactive power compensations SVC and STATCOM have been introduced. Finally, use the simulation software of power system PSCAD to simulate the process of wind power integrating into grid. In the simulation results, it’s obvious that the DFIG has better transient stability than IG; install SVC or STATCOM can improve transient stability of wind farm, but SVC is apt to cause harmonic pollution, and STATCOM can improve transient stability to both kinds of generators.

2013 ◽  
Vol 391 ◽  
pp. 271-276
Author(s):  
Peng Li ◽  
Ning Bo Wang ◽  
De Zhi Chen ◽  
Xiao Rong Zhu ◽  
Yun Ting Song

Increasing penetration level of wind power integration has a significant impact on low-frequency oscillations of power systems. Based on PSD-BPA simulation software, time domain simulation analysis and eigenvalue analysis are employed to investigate its effect on power system low-frequency oscillation characteristic in an outward transmitting thermal generated power bundled with wind power illustrative power system. System damping enhances markedly and the risk of low-frequency oscillation reduce when the generation of wind farm increase. In addition, dynamic reactive power compensations apply to wind farm, and the simulation result indicates that it can improve dynamic stability and enhance the system damping.


Author(s):  
Jawaharlal Bhukya ◽  
Talada Appala Naidu ◽  
Sandeep Vuddanti ◽  
Charalambos Konstantinou

Abstract This paper presents stability enhancement of a test system that is connected with a Wind Farm (WF) by using Power System Stabilizer (PSS) for Synchronous Generator (SG) and Power Oscillation Damper (POD) for Static Var Compensator (SVC). This paper also proposes a coordination mechanism for the controller to effectively damp out the oscillations and make the power system more stable by considering the uncertainties. The uncertainty is considered as wind speed variation and wind power penetration and different locations. The Particle Swarm Optimization (PSO) is used to overcome the controller parameter tuning drawbacks and controller coordination. The SG rotor speed deviation is selected as an objective function with various constraints for PSO. The transient stability analysis is carried out by considering large disturbance that is a three-phase fault. The nonlinear dynamic simulation results are obtained by integrating WF and SG replacement with the same rating WF. Evaluation and analysis are performed for various cases and different combination of without and with controllers. From the simulation results, it is noticed that oscillations in the system are minimized, and stability is enhanced at the maximum level. It also observed that the capability of SG and DFIG under three-phase fault is intensified by using PSO for optimized coordinated controller parameters. The robustness and effectiveness of the proposed approaches are evaluated on the IEEE-11 bus test system.


2015 ◽  
Vol 738-739 ◽  
pp. 1251-1255 ◽  
Author(s):  
Liang Liu ◽  
Hai Ming Li ◽  
Si Qing Sheng ◽  
Huan Li

Although the doubly-fed generator group has a flexible ability of reactive power regulation, when a fault occurs in the power system, the ability will be closed to saturation and we need to adopt measures to support network voltage. In this paper, the model of doubly-fed wind turbine、SVC and STATCOM will be given. And the paper will provide a control system of the two dynamic reactive power compensation devices respectively. By power system simulation software Matlab and combining a regional power grid of Mengdon, both SVC and STATCOM are applied to the wind farm and the paper will analyze the characteristics of network voltage. The simulative results show that both the SVC and STATCOM can help wind farm voltage rapidly reconstructed after the fault. In addition, the STATCOM can better improve the transient stability of the wind farm and the compensation effect of STATCOM is better than SVC.


2013 ◽  
Vol 694-697 ◽  
pp. 846-849
Author(s):  
Jian Yuan Xu ◽  
Wei Fu Qi ◽  
Yun Teng

This paper mainly studies wind power fluctuations how to affect voltage stability after the wind power grid integration, and reactive power compensation equipment on improving effect. In certain parts of the wind farm, for example, firstly, analyzing the wind farm reactive power problems. Then introduce the reactive power compensation equipment that used in the wind farm. Finally, with PSCAD software, making a simulation analysis about the influence on the power grid voltage according to adopting the different reactive power compensation devices or not.


2013 ◽  
Vol 380-384 ◽  
pp. 3051-3056 ◽  
Author(s):  
Xiao Dan Wu ◽  
Wen Ying Liu

In this paper, starting from the active network loss formulas and wind characteristics, it is pointed out the reactive power loss and reactive flow is the major impact of wind power integration on power system loss. The reactive power loss formulas of box-type transformer, main step-up transformer, wind farm collector line and connecting grid line are analyzed. Next the reactive power loss of transformer and transmission line is described in detail. Then put forward the loss reduction measures that installing SVC on the low voltage side of the main step-up transformer and making the doubly-fed wind generators send out some reactive power at an allowed power factor. Use the case of Gansu Qiaodong wind farm to verify the effectiveness of the proposed measures.


2019 ◽  
Vol 9 (4) ◽  
pp. 4384-4388 ◽  
Author(s):  
D. N. Truong ◽  
V. T. Bui

The objective of this paper is to perform a hybrid design for an Adaptive Neuro-Fuzzy Inference System (ANFIS) optimized by Particle Swarm Optimization (PSO) to improve the dynamic voltage stability of a grid-connected wind power system. An onshore 99.2MW wind farm using Doubly Fed Induction Generator (DFIG) is studied. To compensate the reactive power absorbed from the power grid of the wind farm, a Static VAR Compensator (SVC) is proposed. To demonstrate the performance of the proposed hybrid PSO–ANFIS controller, simulations of the voltage response in time-domain are performed in Matlab to evaluate the effectiveness of the designed controller. From the results, it can be concluded that the proposed hybrid PSO-optimized ANFIS-based model can be applied to enhance the dynamic voltage stability of the studied grid-connected wind power system.


2020 ◽  
Vol 10 (24) ◽  
pp. 8874
Author(s):  
Masaki Yagami ◽  
Masanori Ichinohe ◽  
Junji Tamura

This paper proposes a novel control method for enhancing transient stability by using renewable energy sources (RES). The kinetic energy accumulated in a rotor of variable speed wind generator (VSWG) is proactively used as the active power source, which is controlled according to the frequency measured at the wind farm. In addition, coordinated reactive power control according to the grid voltage is also carried out to more effectively use the kinetic energy of the VSWG. The effects of the proposed control system were evaluated by simulation analyses performed using a modified IEEE nine-bus power system network made up of synchronous generators (SGs), a photovoltaic (PV) system and a VSWG-based wind farm. Furthermore, the coordinated reactive power control between the VSWG and PV system was also demonstrated.


2013 ◽  
Vol 385-386 ◽  
pp. 1082-1085 ◽  
Author(s):  
Yan Juan Wu ◽  
Lin Chuan Li ◽  
Fang Zhang

In view of a serious threat for the transient stability of the power system being caused by the large-scale wind farms integration, and combining with advantages of STATCOM which can quickly restore the fault voltage and fastly, flexibly and smoothly compensate the reactive power, a method is proposed using STATCOM controller of to improve transient stability of the power system integrated by large-scale wind farms. The control strategy of the STATCOM controller uses adaptive double loop control. The role of the device to improvement transient stability of the power system is studied under the condition of serious fault. by simulation comparison with the condition without STATCOM controller installed at the same place. The simulation results show that the STATCOM controller can clearly improve transient stability of the power system integrated by large-scale wind farms.


2011 ◽  
Vol 14 (2) ◽  
pp. 80-93
Author(s):  
Chuong Trong Trinh

The scale of wind power plants is increasing continuously in Vietnam. The installed capacity of the largest wind farm is about 50MW by the end of this year. Therefore, power system planners will need to study their impact onthe power system in more detail. Wind energy conversion systems are very different in nature from conventional generators. Therefore dynamic studies must be addressed in order to integrate wind power into the power system. The impact of this wind power on voltage distribution levels has been addressed in the literatures. The majority of this work deals with the determination of the maximum active and reactive power that is possible to be connected on a system load bus, until the voltage at that bus reaches the voltage collapse point. This article introduces the methods of research standards, evaluation criteria of stable electricity supply; it identifies the centers of loads and focuses on the branch is "weak" in small signal stability to improve operational efficiency, reliability in electricity power supply.