scholarly journals Severe Aortic Coarctation in a 75-Year-Old Woman: Total Simultaneous Repair of Aortic Coarctation and Severe Aortic Stenosis

2012 ◽  
Vol 42 (1) ◽  
pp. 62 ◽  
Author(s):  
Ju Hyun Park ◽  
Kook Jin Chun ◽  
Sung Gook Song ◽  
Jeong Su Kim ◽  
Yong Hyun Park ◽  
...  
2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
M V Garcia-Ruiz ◽  
V M Becerra Munoz ◽  
J Robledo-Carmona ◽  
I Rodriguez-Bailon ◽  
E De Teresa Galvan

Abstract Introduction It is well known that bicuspid aortic valve (BAV) is associated with premature valve dysfunction and ascending aorta dilation. However, limited data still exists regarding the rate of growth of the ascending aorta and the risk factors associated with it in these patients. Methods We analyzed prospectively baseline characteristics and echocardiographic data from 192 adult patients with BAV followed in an Adult Congenital Heart Disease Unit from 2007 until 2018. The exclusion criteria were: patient's without at least 2 echocardiographic examinations >6 months apart, and patients with aortic valve and/or ascending aorta surgery at baseline o at follow up (except aortic coarctation). Following the ASE guidelines two cardiologists experts in echocardiography made all the studies at baseline and follow-up where they measured the aortic root and ascending aortic diameters, as well as typified the aortic valve and analyzed the degree of stenosis (AS) and regurgitation (AR). Statistical analysis was performed using Stata 13.1, and a p value of ≤0.05 was considered significant. Results 97 patients were finally included (70 male, mean age 37.56±18.9 years). 66 patients had type A BAV (68.04%), 21 type B (21.7%), 2 type C (2.06%) and 7 unicuspid (7.22%). 19 patients had hypertension (19.59%) and 9 had a corrected aortic coarctation. In baseline echocardiogram, 20 had aortic stenosis ≥ moderate (20.6%) and 38 regurgitation ≥ grade II (39.18%). Mean diameter of ascending aorta was 35.78mm ± 6.73. With a mean follow-up time of 50.53±27.05 months, mean rate of diameter progression was 0.76 mm/year at the proximal ascending aorta (95% CI 0.6 to 1.2). Progression was significantly higher in patients with moderate or severe aortic stenosis (0.65 vs. 1.17 mm/year, p=0.021). Age, sex, hypertension, AR and high baseline diameters (≥40mm or ≥45mm) were not associated with progression. In a direct comparison between the two more frequent forms of BAV, Type A and Type B, rate of diameter progression was significantly higher in Type B (0.61 vs. 1.05 mm/year, p=0.044). In a multivariate analysis, none of the variables statistically associated to major progression were found to be predictors of growth of the ascending aorta. Conclussions In our population of BAV patients, mean rate of diameter progression at the proximal ascending aorta was 0.76 mm/year. Moderate-severe AS, and having type B BAV were associated, but not predictors, of higher growth rates.


2012 ◽  
Vol 15 (4) ◽  
pp. 182
Author(s):  
Fotios A. Mitropoulos ◽  
Meletios A. Kanakis ◽  
Sotiria C. Apostolopoulou ◽  
Spyridon Rammos ◽  
Constantine E. Anagnostopoulos

<p>Mechanical and biological prostheses are valid options when aortic valve replacement is necessary. The Ross procedure is also an alternative solution, especially for young patients.</p><p>We describe the case of a young patient with congenital aortic stenosis and bicuspid aortic valve who presented with dyspnea on exertion. An open commissurotomy was performed, and within 8 months the patient developed recurrent symptoms of severe aortic stenosis. He underwent redo sternotomy and a Ross-Konno procedure with an uneventful recovery.</p>


2014 ◽  
Vol 17 (1) ◽  
pp. 25 ◽  
Author(s):  
Lei Gao ◽  
Qin Wu ◽  
Xinhua Xu ◽  
Tianli Zhao ◽  
Wancun Jin ◽  
...  

<p><b>Background:</b> Severe congenital aortic stenosis in infants is a life-threatening congenital heart anomaly that is typically treated using percutaneous balloon aortic valvuloplasty.</p><p><b>Methods:</b> The usual route is the femoral artery under radiographic guidance. However, this procedure may be limited by the small size of the femoral artery in low-weight infants. An infant weighing only 7 kg with severe aortic stenosis (peak gradient was 103 mmHg) was successfully treated with a novel approach, that is trans-ascending aorta balloon aortic valvuloplasty guided by transesophageal echocardiography.</p><p><b>Results:</b> The patient tolerated the procedure well, and no major complications developed. After the intervention, transesophageal echocardiography indicated a significant reduction of the aortic valvular peak gradient from 103 mmHg to 22 mmHg, no aortic regurgitation was found. Eighteen months after the intervention, echocardiography revealed that the aortic valvular peak gradient had increased to 38 mmHg and that still no aortic regurgitation had occurred.</p><p><b>Conclusions:</b> In our limited experience, trans-ascending aorta balloon aortic valvuloplasty for severe aortic stenosis under transesophageal echocardiography guidance effectively reduces the aortic peak gradient. As this is a new procedure, long-term follow up and management will need to be established. It may be an alternative technique to treat congenital aortic stenosis in low-weight patients.</p>


2009 ◽  
Vol 5 (2) ◽  
pp. 81 ◽  
Author(s):  
Martijn WA van Geldorp ◽  
Johanna JM Takkenberg ◽  
Ad JJC Bogers ◽  
A Pieter Kappetein ◽  
◽  
...  

Over the next few decades the number of patients diagnosed with aortic stenosis is expected to rise as the population ages and the use of several diagnostic tools expands. This will result in a growing need for both medical and surgical treatment and stimulate the development of new diagnostic and surgical techniques. This article briefly describes the prevalence, pathogenesis and clinical presentation of patients with aortic stenosis and focuses on developments in diagnostic tools, treatment strategies and treatment modalities: the use of echocardiography, tissue Doppler imaging, stress testing and biomarkers is discussed, as well as timing of surgery and the role microsimulation can play in prosthesis selection. Furthermore, newly developed transcatheter valve implantation techniques and their possible role in treating ‘inoperable’ or ‘elderly’ patients are discussed.


Sign in / Sign up

Export Citation Format

Share Document