Acute Obstruction of an Endotracheal Tube Due to Large Mucous Plug: Removed Using Flexible Fiberoptic Bronchoscopy: A case report

2005 ◽  
Vol 49 (5) ◽  
pp. 694 ◽  
Author(s):  
Ji Seon Son ◽  
Jong Hun Kim ◽  
Hyung Sun Lim ◽  
Seong Hoon Ko
2005 ◽  
Vol 40 (5) ◽  
pp. 392-397 ◽  
Author(s):  
Jorge L. Ramírez-Figueroa ◽  
Laura G. Gochicoa-Rangel ◽  
David H. Ramírez-San Juan ◽  
Mario H. Vargas

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Erol Karaaslan ◽  
Sedat Akbas ◽  
Ahmet Selim Ozkan ◽  
Cemil Colak ◽  
Zekine Begec

Abstract Background There are doubts among anesthesiologists on the use of the Laryngeal Mask Airway (LMA) in nasal surgeries because of concerns about the occurrence of blood leakages to the airway. We hypothesized that the use of LMA-Supreme (LMA-S) in nasal surgery is comparable with endotracheal tube (ETT) according to airway protection against blood leakage through the fiberoptic bronchoscopy, oropharyngeal leakage pressure (OLP), heart rate (HR), mean arterial pressure (MAP), and postoperative adverse events. Methods The present study was conducted in a prospective, randomized, single-blind, controlled manner on 80 patients, who underwent septoplasty procedures under general anesthesia, after dividing them randomly into two groups according to the device used (LMA-S or ETT). The presence of blood in the airway (glottis/trachea, distal trachea) was analyzed with the fiberoptic bronchoscope and a four-point scale. Both groups were evaluated for OLP; HR; MAP; postoperative sore throat, nausea, and vomiting; dysphagia; and dysphonia. Results In the fiberoptic evaluation of the airway postoperatively, less blood leakage was detected in both anatomic areas in the LMA-S group than in the ETT group (glottis/trachea, p = 0.004; distal trachea, p = 0.034). Sore throat was detected less frequently in the LMA-S group at a significant level in the 2nd, 6th, and 12th hours of postoperative period; however, other adverse events were similar in both groups. Hemodynamic parameters were not different between the two groups. Conclusion The present findings demonstrate that the LMA-S provided more effective airway protection than the ETT in preventing blood leakage in the septoplasty procedures. We believe that the LMA-S can be used safely and as an alternative to the ETT in septoplasty cases. Trial registration This trial is registered at the US National Institutes of Health (ClinicalTrials.gov) # NCT03903679 on April 5, 2019.


CHEST Journal ◽  
1978 ◽  
Vol 73 (6) ◽  
pp. 813-816 ◽  
Author(s):  
Wlademir Pereira ◽  
Daniel M. Kovnat ◽  
Gordon L. Snider

PEDIATRICS ◽  
1991 ◽  
Vol 87 (6) ◽  
pp. 897-899
Author(s):  
Jose A. Birriel ◽  
Jose A. Adams ◽  
Kunjana Mavunda ◽  
Sue Goldfinger ◽  
Donald Vernon ◽  
...  

Flexible fiberoptic bronchoscopy with bronchoalveolar lavage was performed in 16 pediatric patients with the acquired immunodeficiency syndrome (AIDS) and deterioration in pulmonary function suggestive of opportunistic infection. In 62% of the patients Pneumocystis carinii was identified. Culture results showed a pure growth of Pseudomonas aeruginosa for one patient in addition to the Pneumocystis carinii. Bronchoscopy with lavage was well tolerated, with few complications even among patients with significant tachypnea and hypoxia. Because of its relative safety and effectiveness, this procedure should be considered the first invasive measurement used for evaluation of parenchymal lung disease in this population of patients.


2019 ◽  
Vol 33 (6) ◽  
pp. 656-660
Author(s):  
Itsuki Yuasa ◽  
Hiroaki Sakai ◽  
Yasumiko Hirayama ◽  
Takehisa Fukata ◽  
Hiroko Takechi ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document