scholarly journals Anterior segment optical coherence tomography of intraocular lens opacification

2018 ◽  
Vol 66 (6) ◽  
pp. 858 ◽  
Author(s):  
Neha Goel ◽  
Saurabh Choudhry ◽  
Aanchal Mehta ◽  
Nidhi Mahajan
2011 ◽  
Vol 151 (3) ◽  
pp. 406-412.e2 ◽  
Author(s):  
Dhivya Ashok Kumar ◽  
Amar Agarwal ◽  
Gaurav Prakash ◽  
Soosan Jacob ◽  
Yoga Saravanan ◽  
...  

2021 ◽  
pp. 283-287
Author(s):  
Jo Moriya ◽  
Shinichi Sakamoto ◽  
Satoru Inoda ◽  
Hidenori Takahashi ◽  
Hidetoshi Kawashima

Accidental intraocular lens (IOL) implantation into the corneal stroma is a rare clinical entity that can occur during the wound-assisted technique. In this report, we describe a case of an 81-year-old man who underwent cataract surgery in which the IOL was implanted into the corneal stroma with the wound-assisted technique, and we present changes in anterior segment optical coherence tomography. The IOL was removed and reinserted after widening the incision. Air tamponade was created by intracameral injection. An anterior chamber tap was performed 10 h later to reduce increased intraocular pressure. Interlayer separation of the corneal stroma was confirmed 30 min postoperatively but was corrected 4 days later. The patient’s best-corrected visual acuity (BCVA) was logMAR 0.30, and he had been diagnosed with age-related macular degeneration before surgery. Although the opacity of the corneal stroma persisted, BCVA improved to logMAR 0. When using the wound-assisted technique for IOL insertion, surgeons should take care not to implant the IOL into the corneal stroma.


2013 ◽  
Vol 39 (12) ◽  
pp. 1824-1828
Author(s):  
Mohammad Reza Fallah Tafti ◽  
Reza Soltani Moghadam ◽  
Amir Houshang Beheshtnejad ◽  
Mahmoud Jabbarvand ◽  
Masoomeh Mohebi ◽  
...  

2019 ◽  
Vol 30 (2) ◽  
pp. 307-314 ◽  
Author(s):  
José F Costa ◽  
Paula Bompastor-Ramos ◽  
Marco Marques ◽  
Jorge Henriques ◽  
João Póvoa ◽  
...  

Purpose: To determine the prevalence and risk factors related to the opacification of the LS-502-1 intraocular lens. Methods: Cross-sectional study including patients submitted to cataract surgery between January 2010 and March 2012, with implantation of the LS-502-1 intraocular lens. Past medical history was registered and a complete ophthalmologic evaluation, that included best-corrected visual acuity, slit-lamp examination and fundoscopy, was performed. Anterior segment photographs were taken whenever intraocular lens opacification was present. Results: One hundred and sixty-nine eyes of 154 patients were included, mean age 78.5 ± 7.9 years. The average follow-up after intraocular lens implantation was 65.6 ± 10.0 months. Intraocular lens opacification was seen in 53.3% (n = 90) and presented as one of four different patterns: peripheral (15.6%, n = 14), central (4.4%, n = 4), diffuse (71.1%, n = 64) and superficial white deposits (8.9%, n = 8). There was no statistically significant association with systemic or ophthalmic conditions. In patients with bilateral implantation, intraocular lens opacification in one eye was significantly related to intraocular lens opacification in the fellow eye. A significant variability in opacification was found across intraocular lens serial numbers: the odds ratio for opacification in intraocular lens with serial number beginning with 200003 was 6.0 when comparing with the remaining lenses. Conclusion: The opacification prevalence of the LS-502-1 intraocular lens was 53.3%, which is the highest ever described for any intraocular lens model. Our results suggest that this occurrence is secondary to an interaction between unknown patient variables and problems related to intraocular lens manufacturing and storage procedures.


2016 ◽  
Vol 7 (1) ◽  
pp. 249-252
Author(s):  
Oriel Spierer ◽  
Terrence P. O’Brien

A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL) which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful.


Sign in / Sign up

Export Citation Format

Share Document