scholarly journals Electric Field Distribution Analysis in Snowpack by Boundary Element Method

1993 ◽  
Vol 9 (4) ◽  
pp. 275-281 ◽  
Author(s):  
Yoshio Yamaguchi ◽  
Yousuke Ishizuka ◽  
Masakazu Sengoku
Author(s):  
N. Rouger

Purpose – Scientists and engineers have been solving Poisson’s equation in PN junctions following two approaches: analytical solving or numerical methods. Although several efforts have been accomplished to offer accurate and fast analyses of the electric field distribution as a function of voltage bias and doping profiles, so far none achieved an analytic or semi-analytic solution to describe neither a double diffused PN junction nor a general case for any doping profile. The paper aims to discuss these issues. Design/methodology/approach – In this work, a double Gaussian doping distribution is first considered. However, such a doping profile leads to an implicit problem where Poisson’s equation cannot be solved analytically. A method is introduced and successfully applied, and compared to a finite element analysis. The approach is then generalized, where any doping profile can be considered. 2D and 3D extensions are also presented, when symmetries occur for the doping profile. Findings – These results and the approach here presented offer an efficient and accurate alternative to numerical methods for the modeling and simulation of mathematical equations arising in physics of semiconductor devices. Research limitations/implications – A general 3D extension in the case where no symmetry exists can be considered for further developments. Practical implications – The paper strongly simplify and ease the optimization and design of any PN junction. Originality/value – This paper provides a novel method for electric field distribution analysis.


2012 ◽  
Vol 229-231 ◽  
pp. 807-810
Author(s):  
Li Zhang ◽  
Qing Min Li ◽  
Li Na Zhang ◽  
Yu Di Cong

±1000kV DC wall bushing under planning is a complex insulation system which bears the effects imposed by different working conditions. The electric field distribution is concentrated at the bushing outlet terminal, which might result in breakdown discharge especially when short-time abrupt conditions such as polarity reversal occur. In this paper, the finite element method is utilized to analyze electric field distribution and potential distribution of wall bushing during polarity reversal. Electric field distribution and potential distribution at the moment of polarity reversal are obtained, which provides value reference for the study of polarity reversal process.


Sign in / Sign up

Export Citation Format

Share Document