scholarly journals Determination of Azithromycin in Pharmaceutical Formulations by Differential Pulse Voltammetry. Comparison with Fourier Transformed Infrared Spectroscopic Analysis

2006 ◽  
Vol 24 (1) ◽  
pp. 71-81 ◽  
Author(s):  
J Araujo ◽  
R Ortíz ◽  
J M Ortega
2012 ◽  
Vol 24 (5) ◽  
pp. 1141-1146 ◽  
Author(s):  
Eric Oliveira Faria ◽  
Antônio Carlos Viera Lopes Junior ◽  
Dênio Emanuel Pires Souto ◽  
Fernando Roberto Figueiredo Leite ◽  
Flávio Santos Damos ◽  
...  

2014 ◽  
Vol 6 (16) ◽  
pp. 6254-6264
Author(s):  
Piotr Markowski ◽  
Katarzyna Piwowar ◽  
Irena Baranowska

This manuscript shows how to quickly detect the concentration of three iodinated X-ray contrast agents (iopromide, iodixanol and amidotrizoic acid) using differential pulse voltammetry.


1986 ◽  
Vol 51 (11) ◽  
pp. 2466-2472 ◽  
Author(s):  
Jiří Barek ◽  
Antonín Berka ◽  
Ludmila Dempírová ◽  
Jiří Zima

Conditions were found for the determination of 6-mercaptopurine (I) and 6-thioguanine (II) by TAST polarography, differential pulse polarography and fast-scan differential pulse voltammetry at a hanging mercury drop electrode. The detection limits were 10-6, 8 . 10-8, and 6 . 10-8 mol l-1, respectively. A further lowering of the detection limit to 2 . 10-8 mol l-1 was attained by preliminary accumulation of the determined substances at the surface of a hanging mercury drop.


1991 ◽  
Vol 56 (3) ◽  
pp. 595-601 ◽  
Author(s):  
Jiří Barek ◽  
Gulamustafa Malik ◽  
Jiří Zima

Optimum conditions were found for the determination of 4-nitrobiphenyl by fast scan differential pulse voltammetry at a hanging mercury drop electrode in the concentration range 1 . 10-5 to 2 . 10-7 mol l-1. A further increase in sensitivity was attained by adsorptive accumulation of this substance on the surface of the working electrode, permitting determination in the concentration range (2 – 10) . 10-8 mol l-1 with one minute accumulation of the substance in unstirred solution or (2 – 10) . 10-9 mol l-1 with three-minute accumulation in stirred solution. Linear scan voltammetry can be used to determine 4-nitrobiphenyl in the concentration range (2 – 10) . 10-9 mol l-1 with five-minute accumulation in stirred solution, with the advantage of a smoother baseline and smaller interference from substances that yield only tensametric peaks.


2021 ◽  
Author(s):  
Yan Jin ◽  
Tong QI ◽  
Yuqing Ge ◽  
Jin Chen ◽  
Li juan Liang ◽  
...  

In this paper, ultrasensitive electrochemical determination of phosphate in water is achieved by hydrophilic TiO2 modified glassy carbon electrodes for the first time. Differential pulse voltammetry (DPV) method is proposed...


Sign in / Sign up

Export Citation Format

Share Document