scholarly journals Effects of Building Configuration on Seismic Performance of RC Buildings by Pushover Analysis

2015 ◽  
Vol 05 (02) ◽  
pp. 203-213
Author(s):  
Yasser Alashker ◽  
Sohaib Nazar ◽  
Mohamed Ismaiel
2016 ◽  
Vol 10 (1) ◽  
pp. 158-179 ◽  
Author(s):  
Constantinos C. Repapis

The inelastic response of existing reinforced concrete (RC) buildings without seismic details is investigated, presenting the results from more than 1000 nonlinear analyses. The seismic performance is investigated for two buildings, a typical building form of the 60s and a typical form of the 80s. Both structures are designed according to the old Greek codes. These building forms are typical for that period for many Southern European countries. Buildings of the 60s do not have seismic details, while buildings of the 80s have elementary seismic details. The influence of masonry infill walls is also investigated for the building of the 60s. Static pushover and incremental dynamic analyses (IDA) for a set of 15 strong motion records are carried out for the three buildings, two bare and one infilled. The IDA predictions are compared with the results of pushover analysis and the seismic demand according to Capacity Spectrum Method (CSM) and N2 Method. The results from IDA show large dispersion on the response, available ductility capacity, behaviour factor and failure displacement, depending on the strong motion record. CSM and N2 predictions are enveloped by the nonlinear dynamic predictions, but have significant differences from the mean values. The better behaviour of the building of the 80s compared to buildings of the 60s is validated with both pushover and nonlinear dynamic analyses. Finally, both types of analysis show that fully infilled frames exhibit an improved behaviour compared to bare frames.


2013 ◽  
Vol 671-674 ◽  
pp. 1319-1323
Author(s):  
Zi Xue Lei ◽  
Yu Hang Han ◽  
San Sheng Dong ◽  
Jun Qing Guo

A centrally reinforced column is a new type of RC columns, formed by providing a reinforcement skeleton at the central part of the cross section of an ordinary RC column. Tests have shown that as compared with an ordinary RC column, this type of columns has a higher load carrying capacity and ductility. From the pushover analysis of a frame composed of ordinary RC columns and one consisting of centrally reinforced columns, their seismic performance under seismic load of 9-degree intensity was studied according to Chinese code, including target displacements, story-level displacements, interstory drifts, appearance and development of plastic hinges. The results indicate that although the dimensions of cross sections of columns in the frame with centrally reinforced columns are smaller than those of the ordinary frame, the former still has a higher overall load carrying capacity and seismic performance than the latter.


2021 ◽  
Vol 149 ◽  
pp. 106897
Author(s):  
Gianni Blasi ◽  
Daniele Perrone ◽  
Maria Antonietta Aiello ◽  
Maria Rosaria Pecce

2009 ◽  
Vol 13 (3) ◽  
pp. 345-363 ◽  
Author(s):  
Nikos D. Lagaros ◽  
Nikolaos Bakas ◽  
Manolis Papadrakakis

Sign in / Sign up

Export Citation Format

Share Document