Analysis of Seismic Performance of RC Frames with Centrally Reinforced Columns

2013 ◽  
Vol 671-674 ◽  
pp. 1319-1323
Author(s):  
Zi Xue Lei ◽  
Yu Hang Han ◽  
San Sheng Dong ◽  
Jun Qing Guo

A centrally reinforced column is a new type of RC columns, formed by providing a reinforcement skeleton at the central part of the cross section of an ordinary RC column. Tests have shown that as compared with an ordinary RC column, this type of columns has a higher load carrying capacity and ductility. From the pushover analysis of a frame composed of ordinary RC columns and one consisting of centrally reinforced columns, their seismic performance under seismic load of 9-degree intensity was studied according to Chinese code, including target displacements, story-level displacements, interstory drifts, appearance and development of plastic hinges. The results indicate that although the dimensions of cross sections of columns in the frame with centrally reinforced columns are smaller than those of the ordinary frame, the former still has a higher overall load carrying capacity and seismic performance than the latter.

Polymers ◽  
2021 ◽  
Vol 14 (1) ◽  
pp. 75
Author(s):  
Huynh-Xuan Tin ◽  
Ngo-Thanh Thuy ◽  
Soo-Yeon Seo

Various researches have been performed to find an effective confining method using FRP sheet in order to improve the structural capacity of reinforced concrete column. However, most of these researches were undertaken for the columns subjected to concentric compressive load or fully confined RC columns. To date, it remains hard to find studies on partially FRP-confined RC columns under eccentric load. In this manner, an experimental investigation was carried out to assess the performance of rectangular RC column with different patterns of CFRP-wrap subject to eccentric loads in this paper. The experiment consists of fourteen mid-scale rectangular RC columns of 200 mm × 200 mm × 800 mm, including five controlled columns and nine CFRP-strengthened ones. All CFRP-strengthened columns were reinforced with one layer of vertical CFRP sheet with the main fiber along the axial axis at four sides, then divided into three groups according to confinement purpose, namely unconfined, partially CFRP-confined, and fully CFRP-confined group. Two loading conditions, namely uniaxially and biaxially eccentric loads, are considered as one of the test parameters. From the test of uniaxial eccentric load, partial and full CFRP-wraps provided 19% and 33% increased load-carrying capacity at an eccentricity-to-column thickness ratio (e/h) of 0.125, respectively, compared to controlled columns, and 8% and 11% at e/h = 0.25, respectively. For the partially CFRP-confined columns subjected to biaxial eccentric load with e/h = 0.125 and 0.25, the load-carrying capacities were improved by 19% and 31%, respectively. This means that the partial confinement with CFRP effectively improves the load-carrying capacity at larger biaxial eccentric load. It was found that the load-carrying capacity could be properly predicted by using code equations of ACI 440.2R-17 and Fib Bulletin 14 Guideline for the full CFRP-confined or partially CFRP-confined columns under uniaxial load. For partially CFRP-confined columns under biaxial loading, however, the safety factors using the Fib calculation process were 20% to 31% lower than that of uniaxially loaded columns.


Author(s):  
Trung Hieu Nguyen ◽  
Xuan Dat Pham ◽  
Khuong Duy Tran

Strengthening of reinforced concrete (RC) columns is needed when the actual load-carrying capacity of the columns does not reach the required level due to either structural deterioration or increasing acting loads. This experimental study aims to evaluate the strengthening effect on the eccentrically-compressed RC columns using Carbon fiber reinforced polymer (CFRP) sheets, that confine around the column cross-section. Three RC column specimens with the same geometrical dimensions, reinforcement detailing, and concrete compressive strength were cast and tested in the current experimental investigation. One RC column without being strengthened is referred as the control specimen whereas two other RC columns were partially strengthened by CFRP sheets. All three RC columns were axially loaded with the same initial eccentricity e0 of 80 mm. Based on the test results such as the ultimate load-carrying capacity, the load-rotation relationship, and load-curvature at the middle of column height, the effectiveness of the strengthening technique is discussed.


Materials ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3468
Author(s):  
Zbigniew Kolakowski ◽  
Andrzej Teter

The phenomena that occur during compression of hybrid thin-walled columns with open cross-sections in the elastic range are discussed. Nonlinear buckling problems were solved within Koiter’s approximation theory. A multimodal approach was assumed to investigate an effect of symmetrical and anti-symmetrical buckling modes on the ultimate load-carrying capacity. Detailed simulations were carried out for freely supported columns with a C-section and a top-hat type section of medium lengths. The columns under analysis were made of two layers of isotropic materials characterized by various mechanical properties. The results attained were verified with the finite element method (FEM). The boundary conditions applied in the FEM allowed us to confirm the eigensolutions obtained within Koiter’s theory with very high accuracy. Nonlinear solutions comply within these two approaches for low and medium overloads. To trace the correctness of the solutions, the Riks algorithm, which allows for investigating unsteady paths, was used in the FEM. The results for the ultimate load-carrying capacity obtained within the FEM are higher than those attained with Koiter’s approximation method, but the leap takes place on the identical equilibrium path as the one determined from Koiter’s theory.


2018 ◽  
Vol 22 (7) ◽  
pp. 1554-1565 ◽  
Author(s):  
Jianwei Tu ◽  
Kui Gao ◽  
Lang He ◽  
Xinping Li

At present, extensive studies have been conducted relative to the topic of fiber-reinforced polymer(FRP)- reinforced concrete (RC) flexural members, and many design methods have also been introduced. There have, however, been few studies conducted on the topic of FRP-RC compression members. In light of this, eight glass-fiber-reinforced polymer (GFRP)-RC square columns (200×200×600 mm) were tested in order to investigate their axial compression performance. These columns were reinforced with GFRP longitudinal reinforcement and confined GFRP stirrup. These experiments investigated the effects of the longitudinal reinforcement ratio, stirrup configuration (spirals versus hoops) and spacing on the load-carrying capacity and failure modes of GFRP-RC rectangular columns. The test results indicate that the load-carrying capacity of longitudinal GFRP bars accounted for 3%-7% of the ultimate load-carrying capacity of the columns. The ultimate load-carrying capacity of RC columns confined with GFRP spirals increased by 0.8%-1.6% with higher ductility, compared to GFRP hoops. Reducing the stirrup spacing may prevent the buckling failure of the longitudinal bars and increase the ductility and load-carrying capacity of the GFRP-RC columns. It has been found that setting the GFRP compressive strength to 35% of the GFRP maximum tensile strength yields a reasonable estimate of ultimate load-carrying capacity of GFRP-RC columns.


2018 ◽  
Vol 219 ◽  
pp. 02002
Author(s):  
Małgorzata Gordziej-Zagórowska ◽  
Elżbieta Urbańska-Galewska

The influence of eccentricity at intersections of truss members on the load carrying capacity of the truss joint is presented in the paper. The research truss elements were designed as cold-formed open cross section. Analytical calculations, numerical analysis and experimental research were conducted to reveal how the eccentricity affects the effort of material in the joint area. The results of analysis and investigations are compared and discussed. The main achievement of the tests carried out is statement that slender plane members of the compression chords are safe compared with the results of analytical calculations.


2021 ◽  
Vol 245 ◽  
pp. 112836
Author(s):  
Abdoulaye Sanni Bakouregui ◽  
Hamdy M. Mohamed ◽  
Ammar Yahia ◽  
Brahim Benmokrane

1999 ◽  
Vol 121 (1) ◽  
pp. 71-76 ◽  
Author(s):  
J. Błachut ◽  
O. R. Jaiswal

Localized and global, of eigenmode type, initial geometric imperfections were superimposed on perfect torispherical, ellipsoidal, and toroidal shells of circular and elliptical cross section. Reduction of the load-carrying capacity was then calculated numerically for various geometries and the yield point of material which was assumed to be mild steel. Results show that the buckling strength of torispheres and ellipsoids could be strongly affected by imperfections, but reduction of its magnitude was dependent on the choice of imperfection shape and, more importantly, on the imperfection’s location. Calculations carried out for closed toroids of circular cross section show that these shells are not sensitive to eigenmode-type imperfections, while toroids with elliptical cross sections are sensitive to eigen-imperfections.


2013 ◽  
Vol 438-439 ◽  
pp. 706-710
Author(s):  
Ya Bin Yang ◽  
Wan Lin Cao

Shear wall with concrete filled steel tube columns and concealed trusses is a new kind of shear wall. In order to further the seismic performance of the new shear wall, experiment was carried on three 1/5 scale models, which included one traditional RC shear wall, one shear wall with concrete filled steel tube columns, one shear wall with concrete filled steel tube columns and concealed trusses. Based on the experimental study, load-carrying capacity and hysteretic property of each model were analyzed. The study show that the seismic performance of shear wall with concrete filled round steel tube columns and concealed steel trusses has high bearing capacity and good hysteretic property. Load carrying capacity calculation of shear wall with concrete filled steel tube columns and concealed steel trusses were carried out, the calculate results were in good agreement with the measured results.


Author(s):  
Xiandong Liao ◽  
Xiang Hu

The seismic performance of the internal connection of precast prestressed concrete frame was studied systematically, based on the experiment of full-scale model under low cyclic reversed loading. This study was mainly focused on failure pattern, load-carrying capacity, skeleton curves, and hysteresis curves. Furthermore, a nonlinear finite element analysis using Abaqus was carried out to study the characteristics of the internal connection of precast prestressed concrete frame. Results revealed that the damage was concentrated mainly on beam end owing to flexural action, while steel bars in the columns and stirrups in the core region remained elastic until failure occurred. The calculated value of the load-carrying capacity of the internal connection was similar to the experimental one. Present study can be referenced for the application of precast prestressed concrete frame in high seismic zones.


In this paper, 1 group of plain concrete square columns 150×150×600 mm and 11 groups of concrete columns reinforced with glass fiber reinforced polymer (GFRP) were cast and tested, each group contains of 3 specimens. These experiments investigated effect of the main reinforcement ratio, stirrup spacing and contribution of longitudinal GFRP bars on the load carrying capacity of GFRP reinforced concrete (RC) columns. Based on the experiment results, the relationship between load-capacity and reinforcement ratio and the plot of contribution of longitudinal GFRP bars to load-capacity versus the reinforcement ratio were built and analyzed. By increasing the reinforcement ratio from 0.36% to 3.24%, the average ultimate strain in columns at maximum load increases from 2.64% to 75.6% and the load-carrying capacity of GFRP RC columns increases from 3.4% to 25.7% in comparison with the average values of plain concrete columns. Within the investigated range of reinforcement ratio, the longitudinal GFRP bars contributed about 0.72%-6.71% of the ultimate load-carrying capacity of the GFRP RC columns. Meanwhile, with the same configuration of reinforcement, contribution of GFRP bars to load-carrying capacity of GFRP RC columns decreases when increasing the concrete strength. The influence of tie spacing on load-carrying capacity of reinforced columns was also taken into consideration. Additionally, experimental results allow us to propose some modifications on the existing formulas to determine the bearing capacity of the GFRP RC column according to the compressive strength of concrete and GFRP bars.