Production and Characterization of a Monoclonal Antibody to Campylobacter jejuni

2009 ◽  
Vol 72 (4) ◽  
pp. 870-875 ◽  
Author(s):  
S. A. HEO ◽  
R. NANNAPANENI ◽  
M. G. JOHNSON ◽  
J. S. PARK ◽  
K. H. SEO

Campylobacter species are a group of spiral-shaped bacteria that can cause disease in humans and animals. We developed a high-affinity monoclonal antibody (MAb) probe that recognizes Campylobacter jejuni cells. Cell suspensions grown under microaerobic conditions at 42°C for 20 h on Bolton agar plates with lysed horse blood were used as live and heat-killed preparations, centrifuged at 8,000 × g for 20 min, and resuspended in carbonate buffer (pH 9.6) for coating on the enzyme-linked immunosorbent assay plates. BALB/c mice were immunized with C. jejuni sonicated cells at 107 CFU/ml to generate MAb-producing hybridoma clones. Of about 500 initial hybridoma clones, MAb 33D2, which reacted with C. jejuni and Campylobacter coli, was selected for further evaluation. MAb 33D2 is in the immunoglobulin subclass G2a and had relatively weaker reactivity with the C. coli strains tested. MAb 33D2 did not show any cross-reactions with the nine non-Campylobacter bacteria tested in the enzyme-linked immunosorbent assay and had a stronger affinity for C. jejuni as live versus heat-killed cells. In Western blot assays, MAb 33D2 recognized two major antigens of 62 and 43 kDa in extracts from C. jejuni cells but only one antigen of 62 kDa in extracts from C. coli cells.

2002 ◽  
Vol 68 (3) ◽  
pp. 1319-1324 ◽  
Author(s):  
A. D. Sails ◽  
F. J. Bolton ◽  
A. J. Fox ◽  
D. R. A. Wareing ◽  
D. L. A. Greenway

ABSTRACT A PCR enzyme-linked immunosorbent assay (ELISA) assay was applied to the detection of Campylobacter jejuni and Campylobacter coli in environmental water samples after enrichment culture. Bacterial cells were concentrated from 69 environmental water samples by using filtration, and the filtrates were cultured in Campylobacter blood-free broth. After enrichment culture, DNA was extracted from the samples by using a rapid-boiling method, and the DNA extracts were used as a template in a PCR ELISA assay. A total of 51 samples were positive by either PCR ELISA or culture; of these, 43 were found to be positive by PCR ELISA and 43 were found to be positive by culture. Overall, including positive and negative results, 59 samples were concordant in both methods. Several samples were positive in the PCR ELISA assay but were culture negative; therefore, this assay may be able to detect sublethally damaged or viable nonculturable forms of campylobacters. The method is rapid and sensitive, and it significantly reduces the time needed for the detection of these important pathogens by 2 to 3 days.


2001 ◽  
Vol 8 (3) ◽  
pp. 647-651 ◽  
Author(s):  
Glenn J. Merkel ◽  
Barbara A. Scofield

ABSTRACT We employed an inhibition-type enzyme-linked immunosorbent assay (ELISA) to characterize a murine immunoglobulin M monoclonal antibody (MAb) that bound soluble macromolecular peptidoglycan (PG). With this ELISA, the MAb was capable of detecting soluble PG concentrations of less than 10 ng/ml. Enzymatic digestion of PG reduced binding by more than 100-fold, implying that the epitope recognized by this antibody depended on repeating subunits within the glycan backbone. Additionally, the MAb bound to epitopes on both O-acetylated and non-O-acetylated PG fragments from gram-negative bacteria, as well as PG fragments from Staphylococcus aureus and PG fragments released into the medium by a number of gram-positive and gram-negative bacteria.


Hybridoma ◽  
2001 ◽  
Vol 20 (2) ◽  
pp. 117-121 ◽  
Author(s):  
M. Malakaneh ◽  
M.J. Rasaee ◽  
F. Rahbarizadeh ◽  
R. Madani ◽  
M.M. Forozandeh ◽  
...  

2006 ◽  
Vol 13 (3) ◽  
pp. 420-422 ◽  
Author(s):  
S. E. Burastero ◽  
C. Paolucci ◽  
D. Breda ◽  
G. Monasterolo ◽  
R. E. Rossi ◽  
...  

ABSTRACT The Bühlmann CAST 2000 enzyme-linked immunosorbent assay is a potentially useful assay for measuring sulfidoleukotrienes released in vitro by allergen-challenged basophils. However, we observed that the positive-control reagent yielded positive signals in cell-free systems. These false-positive results depended on using a mouse anti-FcεRI monoclonal antibody and were prevented by degranulation-inducing reagents other than mouse monoclonal antibodies.


Sign in / Sign up

Export Citation Format

Share Document