scholarly journals Clinical Results of Isolated Tibial Insert Exchange in Revision Total Knee Arthroplasty

2005 ◽  
Vol 54 (1) ◽  
pp. 63-67
Author(s):  
Hisataka Goto ◽  
Masafumi Kono ◽  
Masatsugu Suehiro ◽  
Kazunari Maeda ◽  
Toshio Kawahara ◽  
...  
2021 ◽  
Vol 103-B (6) ◽  
pp. 1103-1110
Author(s):  
Matthew W. Tetreault ◽  
Jeremy T. Hines ◽  
Daniel J. Berry ◽  
Mark W. Pagnano ◽  
Robert T. Trousdale ◽  
...  

Aims This study aimed to determine outcomes of isolated tibial insert exchange (ITIE) during revision total knee arthroplasty (TKA). Methods From 1985 to 2016, 270 ITIEs were performed at one institution for instability (55%, n = 148), polyethylene wear (39%, n = 105), insert fracture/dissociation (5%, n = 14), or stiffness (1%, n = 3). Patients with component loosening, implant malposition, infection, and extensor mechanism problems were excluded. Results Survivorship free of any re-revision was 68% at ten years. For the indication of insert wear, survivorship free of any re-revision at ten years was 74%. Re-revisions were more frequent for index diagnoses other than wear (hazard ratio (HR) 1.9; p = 0.013), with ten-year survivorships of 69% for instability and 37% for insert fracture/dissociation. Following ITIE for wear, the most common reason for re-revision was aseptic loosening (33%, n = 7). For other indications, the most common reason for re-revision was recurrence of the original diagnosis. Mean Knee Society Scores improved from 54 (0 to 94) preoperatively to 77 (38 to 94) at ten years. Conclusion After ITIE, the risk and reasons for re-revision correlated with preoperative indications. The best results were for polyethylene wear. For other diagnoses, the re-revision rate was higher and the failure mode was most commonly recurrence of the original indication for the revision TKA. Cite this article: Bone Joint J 2021;103-B(6):1103–1110.


2013 ◽  
Vol 28 (1) ◽  
pp. 1-6 ◽  
Author(s):  
Richard P. Baker ◽  
Bassam A. Masri ◽  
Nelson V. Greidanus ◽  
Donald S. Garbuz

2020 ◽  
Author(s):  
Masahiro Hasegawa ◽  
Shine Tone ◽  
Yohei Naito ◽  
Hiroki Wakabayashi ◽  
Akihiro Sudo

Abstract Background: Antibiotic-impregnated hydroxyapatite (HA) has been used as a new drug delivery system for the treatment of periprosthetic joint infection (PJI) of the knee. The aim of this study was to evaluate the clinical results of this treatment in patients with PJI. Methods: Fourteen consecutive cases of PJI of the knee who were scheduled to undergo two-stage knee revision were enrolled. In the first stage, all components were removed with thorough debridement, and antibiotic-impregnated HA was inserted in the bone and joint space. In the second stage, revision total knee arthroplasty (TKA) was performed after eradication of infection. The mean period from removal of all components and treatment with antibiotic-impregnated HA to revision TKA was 3.4 months. Clinical and radiographic evaluations were performed after a mean follow-up of 5.1 years following revision TKA. Predictors of reinfection were evaluated. Results: Eleven patients had no recurrent infection, whereas 3 patients showed recurrent infection. No knees had osteolysis or loosening after revision TKA. The present study demonstrated no predictors for reinfection. Conclusion: Antibiotic-impregnated HA could be effective for the treatment of infected knee arthroplasty.


Joints ◽  
2021 ◽  
Author(s):  
Giacomo Stefani ◽  
Valerio Mattiuzzo ◽  
Greta Prestini ◽  
Carolina Civitenga ◽  
Roberto Calafiore ◽  
...  

Abstract Purpose The aim of this study was to evaluate the efficacy in terms of clinical results and radiographic findings of using metaphyseal sleeves in revision total knee arthroplasty (TKA), and to check if the use of sleeves without stems did not impair such results. Methods In this retrospective study, 141 patients (143 knees) operated in the period 2008 to 2015 met the above-mentioned criteria and were invited to a medical examination including X-rays. A total of 121 knees were available for the study (44 in the group without stems and 77 in the group with stems). Mean follow-up was 63 months for the stemless group and 89 for the group with stems. Knee Society Score (KSS) (objective knee score) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) were used as outcome scores and compared with baseline values, range of motion (ROM) was also compared with preop value and X-rays were also examined and compared with immediate postop X-rays to check signs of loosening and radiolucent lines, if any, and bone ingrowth. Satisfaction of the patients was also investigated using a linear scale from 1 to 10. Results KSS improved from 34 to 81 postop (39 to 81 in the stemless group) (p < 0.01), while WOMAC from 82% preop to 39% postop (76 to 37% in the stemless group) (p < 0.01). Forty-six patients were satisfied, 20 partially satisfied, and 11 unsatisfied (respectively 25–14–5 in the stemless group). ROM improved from 89 degrees preop to 99 degrees postop (93 to 98 degrees in the stemless group). X-rays showed no loosening of the implant, radiolucent lines in 8 patients, and bone ingrowth in 113 out of 121 patients. Conclusion In this midterm follow-up study, we found a significant improvement in clinical results compared with preop values. We found no difference between the two groups (with and without stems) thus suggesting that the use of stemless sleeves does not impair results in revision TKA. Level of Evidence Therapeutic case series, level IV.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Jake von Hintze ◽  
Mika Niemeläinen ◽  
Harri Sintonen ◽  
Jyrki Nieminen ◽  
Antti Eskelinen

Abstract Background The purpose of this study was to determine the mid-term clinical, radiographic and health-related quality of life (HRQoL) outcomes and define the survival rate in patients who had undergone revision total knee arthroplasty (TKA) using the single rotating hinged knee (RHK) design. Methods Between January 2004 and December 2013, 125 revision TKAs were performed at our institution using the single RHK implant. We conducted both a retrospective analysis of prospectively collected outcome data of these patients and a prospective follow-up study of all 39 living patients (41 knees). The follow-up phase included an optional extra follow-up visit, PROM questionnaires, and plain radiographs. Results The ten-year Kaplan-Meier survival rate of the revision RHK knees was 81.7% (95% CI 71.9–91.6%) with re-revision for any reason as the endpoint. Overall, 15 knees (12% of the total) underwent re-revision surgery during the follow-up. The median follow-up was 6.2 years (range, 0–12.7 years) post-operatively for the baseline group. One mechanical hinge mechanism-related failure occurred without any history of trauma or infection. At the time of the final follow-up, the majority of patients evinced a fairly good clinical outcome measured with patient-reported outcome measures and none of the components were radiographically loose. Conclusion We found that in patients undergoing complex revision TKA, fairly good functional outcome and quality of life can be achieved using an RHK implant. Further, it seems that in this type of patient cohort, revision TKA using an RHK implant relieves pain more than it improves ability to function. The NexGen® RHK design can be regarded as a suitable option in complex revision TKA.


Sign in / Sign up

Export Citation Format

Share Document