scholarly journals Measurement report: Mass and Density of Individual Frozen Hydrometeors

2021 ◽  
Author(s):  
Karlie Rees ◽  
Dhiraj Singh ◽  
Eric Pardyjak ◽  
Timothy Garrett

Abstract. A new precipitation sensor, the Differential Emissivity Imaging Disdrometer (DEID), is used to provide the first continuous measurements of the mass, diameter, and density of individual hydrometeors. The DEID consists of an infrared camera pointed at a heated aluminum plate. It exploits the contrasting thermal emissivity of water and metal to determine individual particle mass by assuming that energy is conserved during the transfer of heat from the plate to the particle during evaporation. Particle density is determined from a combination of particle mass and morphology. A Multi-Angle Snowflake Camera (MASC) was deployed alongside the DEID to provide refined imagery of particle size and shape. Broad consistency is found between derived mass-diameter and density-diameter relationships and those obtained in prior studies. However, DEID measurements show a generally weaker dependence with size for hydrometeor density and a stronger dependence for aggregate snowflake mass.

2021 ◽  
Vol 21 (18) ◽  
pp. 14235-14250
Author(s):  
Karlie N. Rees ◽  
Dhiraj K. Singh ◽  
Eric R. Pardyjak ◽  
Timothy J. Garrett

Abstract. A new precipitation sensor, the Differential Emissivity Imaging Disdrometer (DEID), is used to provide the first continuous measurements of the mass, diameter, and density of individual hydrometeors. The DEID consists of an infrared camera pointed at a heated aluminum plate. It exploits the contrasting thermal emissivity of water and metal to determine individual particle mass by assuming that energy is conserved during the transfer of heat from the plate to the particle during evaporation. Particle density is determined from a combination of particle mass and morphology. A Multi-Angle Snowflake Camera (MASC) was deployed alongside the DEID to provide refined imagery of particle size and shape. Broad consistency is found between derived mass–diameter and density–diameter relationships and those obtained in prior studies. However, DEID measurements show a generally weaker dependence with size for hydrometeor density and a stronger dependence for aggregate snowflake mass.


2014 ◽  
Vol 71 (2) ◽  
Author(s):  
Hussain, S. ◽  
M.K Abdul Hamid ◽  
A.R Mat Lazim ◽  
A.R. Abu Bakar

Brake wear particles resulting from friction between the brake pad and disc are common in brake system. In this work brake wear particles were analyzed based on the size and shape to investigate the effects of speed and load applied to the generation of brake wear particles. Scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDX) was used to identify the size, shape and element compositions of these particles. Two types of brake pads were studied which are non-asbestos organic and semi metallic brake pads. Results showed that the size and shape of the particles generatedvary significantly depending on the applied brake load, and less significantly on brake disc speed. The wear particle becomes bigger with increasing applied brake pressure. The wear particle size varies from 300 nm to 600 µm, and contained elements such as carbon, oxygen, magnesium, aluminum, sulfur and iron.


2017 ◽  
Vol 2017 ◽  
pp. 1-9 ◽  
Author(s):  
Zhaolin Lu ◽  
Xiaojuan Hu ◽  
Yao Lu

Particle morphology, including size and shape, is an important factor that significantly influences the physical and chemical properties of biomass material. Based on image processing technology, a method was developed to process sample images, measure particle dimensions, and analyse the particle size and shape distributions of knife-milled wheat straw, which had been preclassified into five nominal size groups using mechanical sieving approach. Considering the great variation of particle size from micrometer to millimeter, the powders greater than 250 μm were photographed by a flatbed scanner without zoom function, and the others were photographed using a scanning electron microscopy (SEM) with high-image resolution. Actual imaging tests confirmed the excellent effect of backscattered electron (BSE) imaging mode of SEM. Particle aggregation is an important factor that affects the recognition accuracy of the image processing method. In sample preparation, the singulated arrangement and ultrasonic dispersion methods were used to separate powders into particles that were larger and smaller than the nominal size of 250 μm. In addition, an image segmentation algorithm based on particle geometrical information was proposed to recognise the finer clustered powders. Experimental results demonstrated that the improved image processing method was suitable to analyse the particle size and shape distributions of ground biomass materials and solve the size inconsistencies in sieving analysis.


Author(s):  
A. Hizal ◽  
B. Sadasivam ◽  
D. Arola

A preliminary study was conducted to evaluate the parametric dependence of the residual stress distributions in bone that result from an abrasive air-jet surface treatment. Specifically, the influence of particle size and shape used in the treatment on the residual stress, propensity of embedding particles and material removal were studied. Rectangular beams of cortical bone were prepared from bovine femurs and treated with aluminum oxide and glass particles with different treatment angles. Residual stresses within the bone were quantified in terms of the radius of curvature of the bone specimens measured before and after the treatments, as well as a function of time to quantify decay in the stress. The sub-surface distribution was also examined using the layer removal technique. Results showed that the particle size and shape could be used to control the amount of material removal and the magnitude of residual stress within the treated surfaces. An increase in size of the glass particles resulted in an increase in the residual stress and a decrease in material removed during the treatment. The magnitude of residual stress ranged from 22 MPa to nearly 44 MPa through modulation of the particle qualities (size and shape). A microscopic examination of the treated surfaces suggests that the residual stresses resulted primarily from near-surface deformation.


Sign in / Sign up

Export Citation Format

Share Document