scholarly journals Peak-fitting and integration imprecision in the Aerodyne aerosol mass spectrometer: effects of mass accuracy on location-constrained fits

2015 ◽  
Vol 8 (11) ◽  
pp. 4615-4636 ◽  
Author(s):  
J. C. Corbin ◽  
A. Othman ◽  
J. D. Allan ◽  
D. R. Worsnop ◽  
J. D. Haskins ◽  
...  

Abstract. The errors inherent in the fitting and integration of the pseudo-Gaussian ion peaks in Aerodyne high-resolution aerosol mass spectrometers (HR-AMSs) have not been previously addressed as a source of imprecision for these or similar instruments. This manuscript evaluates the significance of this imprecision and proposes a method for their estimation in routine data analysis. In the first part of this work, it is shown that peak-integration errors are expected to scale linearly with peak height for the constrained-peak-shape fits performed in the HR-AMS. An empirical analysis is undertaken to investigate the most complex source of peak-integration imprecision: the imprecision in fitted peak height, σh. It is shown that the major contributors to σh are the imprecision and bias inherent in the m/z calibration, both of which may arise due to statistical and physical non-idealities of the instrument. A quantitative estimation of these m/z-calibration imprecisions and biases show that they may vary from ion to ion, even for ions of similar m/z. In the second part of this work, the empirical analysis is used to constrain a Monte Carlo approach for the estimation of σh and thus the peak-integration imprecision. The estimated σh for selected well-separated peaks (for which m/z-calibration imprecision and bias could be quantitatively estimated) scaled linearly with peak height as expected (i.e. as n1). In combination with the imprecision in peak-width quantification (which may be easily and directly estimated during quantification), peak-fitting imprecisions therefore dominate counting imprecisions (which scale as n0.5) at high signals. The previous HR-AMS uncertainty model therefore underestimates the overall fitting imprecision even for well-resolved peaks. We illustrate the importance of this conclusion by performing positive matrix factorization on a synthetic HR-AMS data set both with and without its inclusion. In the third part of this work, the Monte Carlo approach is extended to the case of an arbitrary number of overlapping peaks. Here, a modification to the empirically constrained approach was needed, because the ion-specific m/z-calibration bias and imprecision can generally only be estimated for well-resolved peaks. The modification is to simply overestimate the m/z-calibration imprecision in all cases. This overestimation results in only a slight overestimate of σh, while significantly reducing the sensitivity of σh to the unknown, ion-specific m/z-calibration biases. Thus, with only the measured data and an approximate estimate of the order of magnitude of m/z-calibration biases as input, conservative and unbiased estimates of peak-integration imprecisions may be obtained for each peak in any ensemble of overlapping peaks.

2015 ◽  
Vol 8 (4) ◽  
pp. 3471-3523 ◽  
Author(s):  
J. C. Corbin ◽  
A. Othman ◽  
J. D. Haskins ◽  
J. D. Allan ◽  
B. Sierau ◽  
...  

Abstract. The errors inherent in the fitting and integration of the pseudo-Gaussian ion peaks in Aerodyne High-Resolution Aerosol Mass Spectrometers (HR-AMS's) have not been previously addressed as a source of imprecision for these instruments. This manuscript evaluates the significance of these uncertainties and proposes a method for their estimation in routine data analysis. Peak-fitting uncertainties, the most complex source of integration uncertainties, are found to be dominated by errors in m/z calibration. These calibration errors comprise significant amounts of both imprecision and bias, and vary in magnitude from ion to ion. The magnitude of these m/z calibration errors is estimated for an exemplary data set, and used to construct a Monte Carlo model which reproduced well the observed trends in fits to the real data. The empirically-constrained model is used to show that the imprecision in the fitted height of isolated peaks scales linearly with the peak height (i.e., as n1), thus contributing a constant-relative-imprecision term to the overall uncertainty. This constant relative imprecision term dominates the Poisson counting imprecision term (which scales as n0.5) at high signals. The previous HR-AMS uncertainty model therefore underestimates the overall fitting imprecision. The constant relative imprecision in fitted peak height for isolated peaks in the exemplary data set was estimated as ~4% and the overall peak-integration imprecision was approximately 5%. We illustrate the importance of this constant relative imprecision term by performing Positive Matrix Factorization (PMF) on a~synthetic HR-AMS data set with and without its inclusion. Finally, the ability of an empirically-constrained Monte Carlo approach to estimate the fitting imprecision for an arbitrary number of known overlapping peaks is demonstrated. Software is available upon request to estimate these error terms in new data sets.


RSC Advances ◽  
2021 ◽  
Vol 11 (54) ◽  
pp. 33849-33857
Author(s):  
Shahram Lotfi ◽  
Shahin Ahmadi ◽  
Parvin Kumar

The melting points of imidazolium ILs are studied employing a quantitative structure–property relationship (QSPR) approach to develop a model for predicting the melting points of a data set of imidazolium ILs.


2009 ◽  
Vol 8 (3-4) ◽  
pp. 324-335 ◽  
Author(s):  
Damien Querlioz ◽  
Huu-Nha Nguyen ◽  
Jérôme Saint-Martin ◽  
Arnaud Bournel ◽  
Sylvie Galdin-Retailleau ◽  
...  

2020 ◽  
Vol 219 ◽  
pp. 116945
Author(s):  
Vasilis Pagonis ◽  
Sebastian Kreutzer ◽  
Alex Roy Duncan ◽  
Ena Rajovic ◽  
Christian Laag ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document