scholarly journals Review of variations in <i>M</i><sub>w</sub> < 7 earthquake motions on position and TEC (<i>M</i><sub>w</sub> = 6.5 Aegean Sea earthquake sample)

2016 ◽  
Vol 16 (2) ◽  
pp. 543-557 ◽  
Author(s):  
Omer Yildirim ◽  
Samed Inyurt ◽  
Cetin Mekik

Abstract. Turkey is a country located in the middle latitude zone, where tectonic activity is intensive. Recently, an earthquake of magnitude 6.5  Mw occurred offshore in the Aegean Sea on 24 May 2014 at 09:25 UTC, which lasted about 40 s. The earthquake was also felt in Greece, Romania, and Bulgaria in addition to Turkey. In recent years, ionospheric anomaly detection studies have been carried out because of seismicity with total electron content (TEC) computed from the global navigation satellite system's (GNSS) signal delays and several interesting findings have been published. In this study, both TEC and positional variations have been examined separately following a moderate size earthquake in the Aegean Sea. The correlation of the aforementioned ionospheric variation with the positional variation has also been investigated. For this purpose, a total of 15 stations was used, including four continuously operating reference stations in Turkey (CORS-TR) and stations in the seismic zone (AYVL, CANA, IPSA, and YENC), as well as international GNSS service (IGS) and European reference frame permanent network (EPN) stations. The ionospheric and positional variations of the AYVL, CANA, IPSA, and YENC stations were examined using Bernese v5.0 software. When the precise point positioning TEC (PPP-TEC) values were examined, it was observed that the TEC values were approximately 4 TECU (total electron content unit) above the upper-limit TEC value at four stations located in Turkey, 3 days before the earthquake at 08:00 and 10:00 UTC. At the same stations, on the day before the earthquake at 06:00, 08:00, and 10:00 UTC, the TEC values were approximately 5 TECU below the lower-limit TEC value. The global ionosphere model TEC (GIM-TEC) values published by the Centre for Orbit Determination in Europe (CODE) were also examined. Three days before the earthquake, at all stations, it was observed that the TEC values in the time period between 08:00 and 10:00 UTC were approximately 2 TECU above the upper-limit TEC value; 1 day before the earthquake at 06:00, 08:00, and 10:00 UTC, the TEC values were approximately 4 TECU below the lower-limit TEC value. Again, by using the same 15 stations, positional variation investigation for before and after the earthquake was undertaken for the AYVL, CANA, IPSA, and YENC stations. As a result of the conducted analysis, positional displacements were seen before and after the earthquake at the CANA station, which is the nearest station to the earthquake centre. Before and after the earthquake, positional displacements were observed as 10 and 3 cm respectively.

2015 ◽  
Vol 3 (10) ◽  
pp. 5923-5956
Author(s):  
O. Yildirim ◽  
S. Inyurt ◽  
C. Mekik

Abstract. Turkey is a country located in Middle Latitude zone and in which tectonic activity is intensive. Lastly, an earthquake of magnitude 6.5Mw occurred at Aegean Sea offshore on date 24 May 2014 at 12:25 UTC and it lasted approximately 40 s. The said earthquake was felt also in Greece, Romania and Bulgaria in addition to Turkey. In recent years seismic origin ionospheric anomaly detection studies have been done with TEC (Total Electron Contents) generated from GNSS (Global Navigation Satellite System) signals and the findings obtained have been revealed. In this study, TEC and positional variations have been examined seperately regarding the earthquake which occurred in the Aegean Sea. Then The correlation of the said ionospheric variation with the positional variation has been investigated. For this purpose, total fifteen stations have been used among which the data of four numbers of CORS-TR stations in the seismic zone (AYVL, CANA, IPSA, YENC) and IGS and EUREF stations are used. The ionospheric and positional variations of AYVL, CANA, IPSA and YENC stations have been examined by Bernese 5.0v software. When the (PPP-TEC) values produced as result of the analysis are examined, it has been understood that in the four stations located in Turkey, three days before the earthquake at 08:00 and 10:00 UTC, the TEC values were approximately 4 TECU above the upper limit TEC value. Still in the same stations, one day before the earthquake at 06:00, 08:00 and 10:00 UTC, it is being shown that the TEC values were approximately 5 TECU below the lower limit TEC value. On the other hand, the GIM-TEC values published by the CODE center have been examined. Still in all stations, it has been observed that three days before the earthquake the TEC values in the time portions of 08:00 and 10:00 UTC were approximately 2 TECU above, one day before the earthquake at 06:00, 08:00 and 10:00 UTC, the TEC values were approximately 4 TECU below the lower limit TEC value. Again, by using the same fifteen numbers of stations, positional variation investigation before and after the earthquake has been made for AYVL, CANA, IPSA and YENC stations. As result of the analysis made, positional displacements has been seen before and after earthquake at CANA station which is the nearest station to earthquake center. It is about 10 and 3 cm before three days and one day earthquake.


1989 ◽  
Author(s):  
Jr. Mazzella ◽  
Larson Andrew J. ◽  
Dickson Kevin P. ◽  
Peter

2004 ◽  
Vol 6 (5) ◽  
pp. 339-354 ◽  
Author(s):  
E. L. Afraimovich ◽  
E. I. Astafieva ◽  
M. B. Gokhberg ◽  
V. M. Lapshin ◽  
V. E. Permyakova ◽  
...  

2017 ◽  
Vol 122 (7) ◽  
pp. 7519-7529 ◽  
Author(s):  
A. R. Paulino ◽  
L. M. Lima ◽  
S. L. Almeida ◽  
P. P. Batista ◽  
I. S. Batista ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document