scholarly journals Dynamic hip screw plate

2021 ◽  
Author(s):  
Subhan Iqbal
Keyword(s):  
2019 ◽  
Vol 9 (3) ◽  
pp. 65-71
Author(s):  
Sujana Theja J S ◽  
◽  
Kiran Marathe ◽  
B Gurumurthy ◽  
Pavankumar Patted ◽  
...  

Author(s):  
Anderson Freitas ◽  
Landwehrle de Lucena da Silva ◽  
Renilton Rodrigues Costa ◽  
Lucas Sacramento Ramos ◽  
Marcos Norberto Giordano ◽  
...  

Resumo Objetivo Identificar a energia necessária para ocorrência de fratura do fêmur proximal em osso sintético após retirada de três modelos de implantes: parafusos canulados, parafuso dinâmico do quadril (dynamic hip screw-DHS) e haste femoral proximal (proximal femoral nail-PFN). Métodos Foram utilizados 25 modelos de ossos sintéticos da extremidade proximal do fêmur: 10 unidades de grupo controle (GC), 5 unidades após colocação e retirada de 3 parafusos canulados colocados em configuração de triângulo invertido (GPC), 5 unidades após colocação e retirada do parafuso de compressão dinâmico (GDHS), e 5 unidades após colocação e retirada da haste de fêmur proximal (GPFN). Uma análise biomecânica foi realizada em todas as amostras simulando uma queda sobre o grande trocânter utilizando uma máquina servo-hidráulica com o objetivo de verificar a energia (em Joules [J]) necessária até a ocorrência de fratura nos diferentes grupos. Resultados Todos os grupos apresentaram fratura basocervical. Os grupos GC, GPC, GDHS e GPFN apresentaram, respectivamente, valores de 7.1J, 6.6J, 6J e 6.7J de energia até ocorrência da fratura. Não houve diferença estatisticamente significativa (intervalo de confiança de 95%) na energia entre os grupos de estudo (p = 0,34). Conclusão Não houve diferença estatisticamente significativa nos valores de energia necessária para ocorrência de fratura da extremidade proximal do fêmur após a retirada de três tipos de implantes utilizando modelos sintéticos simulando queda sobre o grande trocânter.


2020 ◽  
Vol 48 (12) ◽  
pp. 030006052095093
Author(s):  
Hua-Biao Chen ◽  
Hong-Bo Wu ◽  
Min Chen ◽  
Yu-Liang Huang

Background Femoral head collapse and coxa vara lead to internal fixator failure in elderly patients with hip fracture. External fixator application is an optimal choice; however, the existing methods have many disadvantages. Methods Type 31-A1.3 hip fracture models were developed in nine pairs of 1-year-old fresh bovine corpse femur specimens. Each left femur specimen was fixed by a dynamic hip screw (control group), and each right femur specimen was fixed by the slide-poking external fixator (experimental group). Vertical loading and torsion tests were then performed in both groups. Results In the vertical loading experiment, a 1000-N load was implemented. The mean vertical downward displacement of the femoral head in the experimental and control groups was 1.49322 ± 0.116280 and 2.13656 ± 0.166374 mm, respectively. In the torsion experiment, when the torsion was increased to 10.0 Nm, the mean torsion angle in the experimental and control groups was 7.9733° ± 1.65704° and 15.4889° ± 0.73228°, respectively. The slide-poking external fixator was significantly more resistant to compression and rotation than the dynamic hip screw. Conclusion The slide-poking external fixator for hip fractures that was designed and developed in this study can provide sufficient stability to resist compression and rotation in hip fractures.


2007 ◽  
Vol 40 ◽  
pp. S572-S573
Author(s):  
Shih Liang Shih ◽  
Jui-Sheng Sun ◽  
Yang-Hwei Tsuang ◽  
Chen-Sheng Chen ◽  
Cheng-Kung Cheng

Sign in / Sign up

Export Citation Format

Share Document