RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF LINAGLIPTIN AND EMPAGLIFLOZIN

INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (05) ◽  
pp. 68-71
Author(s):  
A Lakshmana Rao ◽  
◽  
T. Prasanthi ◽  
E. L Anusha

A simple, accurate and precise RP-HPLC method was developed for the simultaneous estimation of the linagliptin and empagliflozin in tablet dosage form. Chromatogram was run through Kromasil 250 x 4.6 mM, 5mM column, mobile phase containing 0.1% o-phosphoric acid buffer and acetonitrile in the ratio of 60:40%v/v was pumped through column at a flow rate of 1 mL/min. The optimized wavelength was 230 nm. Retention times of linagliptin and empagliflozin were found to be 2.759 min and 2.139 min. %RSD of the Linagliptin and Empagliflozin were found to be 0.5 and 0.6 respectively. Percentage assay was obtained as 99.91% and 100.15% for linagliptin and empagliflozin, respectively. LOD, LOQ values obtained for linagliptin and empagliflozin were 0.23 μg/ml and 0.44 μg/mL and 0.70 μg/mL and 1.34 μg/mL, respectively. Thus, the current study showed that the developed RP-HPLC method is sensitive and selective for the estimation of linagliptin and empagliflozin in combined dosage form.

2014 ◽  
Vol 1 (3) ◽  
pp. 50
Author(s):  
Ananda Thangadurai Subramaniam ◽  
Jambulingam Munusamy ◽  
Saravanakumar Sengodan ◽  
Kamalakannan Danapal ◽  
Haritha D Siva Ganga Lakshmi ◽  
...  

2018 ◽  
Vol 34 (5) ◽  
pp. 2554-2561
Author(s):  
D. China Babu ◽  
C. Madhusudhana Chetty ◽  
S. K. Mastanamma

A selective, sensitive RP-HPLC method was developed for the simultaneous estimation of the Ertugliflozin (ETR) and Sitagliptin (SGT) in bulk and its dosage form. The separation and determination was carried on water’s C18 column capacitate (250X4.6 mm, 5 µm particle size), retention times of Ertugliflozin and Sitagliptin were found to be 2.39 and 4.60 min respectively. The wavelength was fixed at 215nm with PDA detection. The mobile phase was consisted mixture of 0.5 mM potassium dihydrogen ortho phosphate buffer: Methanol in the ratio of 55:45 v/v, pH 5.3 was adjusted with HCl and flow of mobile phase was maintained 1mL/min. The calibration curve was linear and regression co-efficient (R2) value found to be 0.999 and concentration ranging from 37.5-112.5 and 250-750 µg/mL for Ertugliflozin & Sitagliptin respectively. The quantization limit and detection limit of the method were found 0.1 & 0.3 µg/ml and 0.4&1µg/ml for Ertugliflozin & Sitagliptin.


INDIAN DRUGS ◽  
2015 ◽  
Vol 52 (07) ◽  
pp. 5-9
Author(s):  
L Kalyani ◽  
◽  
A. L. Rao

A simple, precise and accurate RP-HPLC method was developed and validated for the simultaneous estimation of aliskiren and valsartan in combined tablet dosage form. The chromatographic separation of the two drugs was achieved on Symmetry C8 column (250 x 4.6 mm, 5 μm). The mobile phase consisted of acetate buffer: acetonitrile (60:40 V/V) and pH was adjusted to 5.8 with glacial acetic acid was delivered at the flow rate of 1.4 mL/min and detection was performed at 220 nm. Separation was completed within 4 minutes. The calibration curves were linear with a correlation coefficient of 0.999 over the concentration range of 7.5 to 75 µg/mL of aliskiren and 8 to 80 µg/mL of valsartan. The relative standard deviation (RSD) was found