scholarly journals Repair of residual aortic dissections with frozen elephant trunk technique

2020 ◽  
Vol 28 (3) ◽  
pp. 419-425
Author(s):  
Mustafa Akbulut

Background: In this study, we present our mid-term results of reoperation with the frozen elephant trunk procedure due to patent false lumen-related complications in patients previously undergoing supracoronary aortic repair for acute type A aortic dissection. Methods: Between January 2013 and September 2018, a total of 23 patients (17 males, 6 females; mean age 51.5±9.7 years; range, 30 to 67 years) who underwent ascending aortic replacement due to type A aortic dissection and, later, frozen elephant trunk procedure for residual distal dissection were included. For diagnostic purposes and follow-up, computed tomography angiography was performed in all patients, and both re-entry and aortic diameters were evaluated. Echocardiography was used to evaluate cardiac function and valve pathologies. Results: The Ishimaru zone 0 (n=11, 47.8%), Ishimaru zone 1 (n=1, 4.3%), Ishimaru zone 2 (n=4, 17.4%), and Ishimaru zone 3 (n=7, 30.4%) were used for frozen elephant trunk stent graft fixation. The mean duration of cardiopulmonary bypass and antegrade selective cerebral perfusion was 223.9±71.2 min and 88.9±60.3 min, respectively. In-hospital mortality was 13%, while there was one (4.3%) aortic-related death and four (17.4%) re-interventions during follow-up. Conclusion: Early repair should be considered in the presence of persistent dissections due to alarmingly high mortality rates of reoperations. Reoperation with the frozen elephant trunk procedure has acceptable results and the decision of the procedure to be performed should be based on preoperative risk factors of the patient.

Author(s):  
Chaojie Wang ◽  
Wenqian Zhang ◽  
Jihai Peng ◽  
Jie He ◽  
Wenliu Xu ◽  
...  

OBJECTIVES: The frozen elephant trunk (FET) technique has become an important tool in the treatment of acute type A aortic dissection. The aim of this study was to evaluate the effect of long FET on spinal cord injury (SCI) and distal aortic remodeling after acute type A aortic dissection based on clinical and radiological outcomes. METHODS: From January 2018 to November 2019, 158 patients [mean age 51.8 years (range 32 - 78 years), 88.6% male] with acute type A aortic dissection were treated by FET with 100 mm (n=113) or 150 mm (n=45) open hybrid stent graft prosthesis. Patients were divided into two groups according to the length of FET. The clinical and radiological outcomes of the patients were reviewed retrospectively. RESULTS: Postoperative outcomes did not differ significantly: in-hospital mortality (9.7% vs 6.7%, P=0.758) and SCI (5.3% vs 2.2%, P=0.674). Aortic remodeling, which was evaluated by aortic diameter, true lumen diameter, false lumen diameter and the rate of false lumen complete thrombosis, was more positive in long FET group in the descending thoracic aorta during the follow-up period. At the abdominal level, there was no statistically significant difference between the two groups. CONCLUSIONS: The long version of FET does not increase the risk of SCI in patients with acute type A aortic dissection. The application of long FET can achieve better results in terms of remodeling of the thoracic aorta in the short- and medium-term follow-up.


2021 ◽  
Author(s):  
Chaojie Wang ◽  
Wenqian Zhang ◽  
Jihai Peng ◽  
Jie He ◽  
Guangtian Chen ◽  
...  

Abstract Background: The frozen elephant trunk (FET) technique has become an important tool in the treatment of acute type A aortic dissection. The aim of this study was to evaluate the effect of long FET on spinal cord injury (SCI) and distal aortic remodeling after acute type A aortic dissection based on clinical and radiological outcomes.METHODS: From January 2018 to November 2019, 158 patients [mean age 51.8 years (range 32 - 78 years), 88.6% male] with acute type A aortic dissection were treated by FET with 100 mm (n=113) or 150 mm (n=45) open hybrid stent graft prosthesis. Patients were divided into two groups according to the length of FET. The clinical and radiological outcomes of the patients were reviewed retrospectively. RESULTS: Postoperative outcomes did not differ significantly: in-hospital mortality (9.7% vs 6.7%, P=0.758) and SCI (5.3% vs 2.2%, P=0.674). Aortic remodeling, which was evaluated by aortic diameter, true lumen diameter, false lumen diameter and the rate of false lumen complete thrombosis, was more positive in long FET group in the descending thoracic aorta during the follow-up period. At the abdominal level, there was no statistically significant difference between the two groups. In the long FET group, the level of complete false lumen thrombosis was more extensive during the follow-up period. CONCLUSIONS: The long version of FET does not increase the risk of SCI in patients with acute type A aortic dissection. The application of long FET can achieve better results in terms of remodeling of the thoracic aorta in the short- and medium-term follow-up.


Author(s):  
Jan Raupach ◽  
Vendelin Chovanec ◽  
Veronika Kozakova ◽  
Jan Vojacek

Abstract We report a case of a 51-year-old male with complicated acute type A aortic dissection who initially underwent a supracoronary and aortic arch replacement using frozen elephant trunk technique. False-lumen perfusion was revealed later which resulted in the collapse of the true lumen. Endovascular fenestration of the dissection flap was performed. True-lumen reperfusion with false-lumen regression was achieved. Endovascular fenestration using a re-entry catheter represents an efficient and safe treatment approach for this rare but serious complication.


2020 ◽  
Vol 31 (6) ◽  
pp. 813-819
Author(s):  
Daisuke Kaneyuki ◽  
Kenji Mogi ◽  
Hiroyuki Watanabe ◽  
Masayoshi Otsu ◽  
Manabu Sakurai ◽  
...  

Abstract OBJECTIVES Our goal was to determine the early and midterm outcomes after total arch replacement with the frozen elephant trunk (FET) technique compared to those of the conventional elephant trunk (ET) technique for acute retrograde type A aortic dissection. METHODS Between 2012 and 2019, a total of 49 patients had total arch replacement for acute retrograde type A aortic dissection. Patients were divided into the conventional ET (n = 17) and FET (n = 32) groups. The false lumen status was evaluated using enhanced computed tomography (CT) 1 week postoperatively. The diameter of the downstream aorta was evaluated annually using CT. The median follow-up period was 29 months. RESULTS Preoperative data and neurological complications were not significantly different in the 2 groups. The diameter and length of the ET prosthesis were significantly larger and longer in the FET group. The overall early mortality rate was 10.2% (5/49) with no differences between the 2 groups. The mean follow-up period was significantly longer in the conventional ET group. The rates of freedom from aortic events at 3 years were significantly lower in the FET group. At the level of the distal arch, postoperative false lumen patency was significantly lower and the follow-up aortic diameter was significantly smaller in the FET group. CONCLUSIONS The FET technique facilitates false lumen thrombosis and aortic remodelling at the distal arch level, with fewer adverse aortic events during the follow-up period with acceptable early outcomes; however, these findings are exploratory and require investigation.


2021 ◽  
Vol 8 ◽  
Author(s):  
Penghong Liu ◽  
Bing Wen ◽  
Chao Liu ◽  
Huashan Xu ◽  
Guochang Zhao ◽  
...  

Objective: The study objective was to evaluate the effect of en bloc arch reconstruction with frozen elephant trunk (FET) technique for acute type A aortic dissection.Methods: 41 patients with acute Stanford type A dissection underwent en bloc arch reconstruction combined with FET implantation between April 2018 and August 2020. The mean age of the patients was 46 ± 13 years, and 9 patients were female. One patient had Marfan syndrome. Six patients had pericardial tamponade, 9 had pleural effusion, 5 had transient cerebral ischemic attack, and 3 had chronic kidney disease.Results: The hospital mortality rate was 9.8% (4 patients). 2 (4.9%) patients had stroke, 23 (56.1%) had acute kidney injury, and 5 (12.2%) had renal failure requiring hemodialysis. During follow-up, the rate of complete false lumen thrombosis was 91.6% (33/36) around the FET, 69.4% (25/36) at the diaphragmatic level, and 27.8% (10/36) at the superior mesenteric artery level. The true lumen diameter at the same three levels of the descending aorta increased significantly while the false lumen diameter reduced at the two levels: pulmonary bifurcation and the diaphragm. The 1-, 2-and 3-year actuarial survival rates were 90.2% [95% confidence interval (CI), 81.2–99.2], 84.2% (95% CI, 70.1–98.3) and 70.2% (95% CI, 42.2–98), respectively.Conclusions: In patients with acute type A dissection, en bloc arch reconstruction with FET technique appeared to be feasible and effective with early clinical follow-up results. Future studies including a large sample size and long-term follow-up are required to evaluate the efficacy.


Author(s):  
Homare Okamura ◽  
Yuichiro Kitada ◽  
Atsushi Miyagawa ◽  
Mamoru Arakawa ◽  
Hideo Adachi

Abstract OBJECTIVES We investigated the outcomes of a fenestrated frozen elephant trunk (FET) technique performed without reconstruction of one or more supra-aortic vessels for aortic repair in patients with acute type A aortic dissection. METHODS We investigated 22 patients who underwent the fenestrated FET technique for acute type A aortic dissection at our hospital between December 2017 and April 2020. The most common symptom was chest pain and/or back pain. Nine patients presented with malperfusion and 1 with cardiac arrest, preoperatively. A FET was deployed under hypothermic circulatory arrest and manually fenestrated under direct vision. Single fenestration was made in the FET in 15 patients, 2 fenestrations in 5 patients and a total fenestrated technique in 2 patients. Concomitant procedures were performed in 5 patients. RESULTS The cardiopulmonary bypass, aortic cross-clamp and hypothermic circulatory arrest times were 181 ± 49, 106 ± 43 and 37 ± 7 min, respectively. In-hospital mortality, stroke, or recurrent nerve injury did not occur in any patient. One patient developed paraparesis, which completely recovered at discharge. During the follow-up period (mean 18 ± 7 months), 1 patient died of heart failure. Fenestration site occlusion did not occur. Follow-up computed tomography (mean 12 ± 6 months postoperatively) revealed that the maximal aortic diameter remained unchanged at the levels of the distal end of the FET, the 10th thoracic vertebra and the coeliac artery; however, the aortic diameter was significantly reduced at the level of the pulmonary artery bifurcation. CONCLUSIONS The fenestrated FET technique is a simple, safe and effective procedure for selected patients with acute type A aortic dissection.


Sign in / Sign up

Export Citation Format

Share Document