scholarly journals Home sleep apnea testing for chronic heart failure: time to break the Cheyne?

Author(s):  
Christina S. Thornton ◽  
Sachin R. Pendharkar
Author(s):  
ShengNan Li ◽  
LiYue Xu ◽  
XiaoSong Dong ◽  
XueLi Zhang ◽  
Brendan T. Keenan ◽  
...  

Author(s):  
Kristofer Montazeri ◽  
Sigurdur Aegir Jonsson ◽  
Jon Skirnir Agustsson ◽  
Marta Serwatko ◽  
Thorarinn Gislason ◽  
...  

Abstract Purpose Evaluate the effect of respiratory inductance plethysmography (RIP) belt design on the reliability and quality of respiratory signals. A comparison of cannula flow to disposable cut-to-fit, semi-disposable folding and disposable RIP belts was performed in clinical home sleep apnea testing (HSAT) studies. Methods This was a retrospective study using clinical HSAT studies. The signal reliability of cannula, thorax, and abdomen RIP belts was determined by automatically identifying periods during which the signals did not represent respiratory airflow and breathing movements. Results were verified by manual scoring. RIP flow quality was determined by examining the correlation between the RIP flow and cannula flow when both signals were considered reliable. Results Of 767 clinical HSAT studies, mean signal reliability of the cut-to-fit, semi-disposable, and disposable thorax RIP belts was 83.0 ± 26.2%, 76.1 ± 24.4%, and 98.5 ± 9.3%, respectively. The signal reliability of the cannula was 92.5 ± 16.1%, 87.0 ± 23.3%, and 85.5 ± 24.5%, respectively. The automatic assessment of signal reliability for the RIP belts and cannula flow had a sensitivity of 50% and a specificity of 99% compared with manual assessment. The mean correlation of cannula flow to RIP flow from the cut-to-fit, semi-disposable, and disposable RIP belts was 0.79 ± 0.24, 0.52 ± 0.20, and 0.86 ± 0.18, respectively. Conclusion The design of RIP belts affects the reliability and quality of respiratory signals. The disposable RIP belts that had integrated contacts and did not fold on top of themselves performed the best. The cut-to-fit RIP belts were most likely to be unreliable, and the semi-disposable folding belts produced the lowest-quality RIP flow signals compared to the cannula flow signal.


SLEEP ◽  
2021 ◽  
Vol 44 (Supplement_2) ◽  
pp. A168-A168
Author(s):  
Mihaela Bazalakova ◽  
Abigail Wiedmer ◽  
Lauren Rice ◽  
Sakshi Bajaj ◽  
Natalie Jacobson ◽  
...  

Abstract Introduction Sleep apnea is emerging as an important and underdiagnosed comorbidity in pregnancy. Screening, diagnosis, and initiation of therapy are all time-sensitive processes during the dynamic progression of gestation. Completion of referral and testing for sleep apnea during pregnancy requires a significant commitment of time and effort on the part of the pregnant patient. We evaluated for predictors of non-completion of sleep apnea testing within our obstetric-sleep referral pipeline, in an effort to inform and optimize future referrals. Methods We performed a retrospective chart-review of 405 pregnant patient referrals for sleep apnea evaluation at the University of Wisconsin-Madison/UnityPoint sleep apnea pregnancy clinic. We used logistic regression analysis to determine predictors of lack of completion of sleep apnea testing. Results The vast majority of referrals (>95%) were triaged directly to home sleep apnea testing with the Alice PDX portable device, rather than a sleep clinic visit. The overall rate of referral non-completion was 59%. Predictors of non-completion of sleep apnea evaluation in our pregnant population included higher gestational age (GA) at referral (1–12 wks GA: 30%, 13–26 wks GA: 31%, and 27–40 wks GA: 57% non-completers, p=0.006) and multiparity with 1 or more living children (65% non-completers if any living children, compared to 45% non-completers if no living children, p=0.002). Age, race, and transportation were not predictors of failure to complete sleep apnea testing. Conclusion We have identified several predictors of pregnant patients’ failure to complete sleep apnea evaluation with objective home sleep apnea testing after referral from obstetrics. Not surprisingly, higher gestational age emerged as a strong negative predictor of referral completion, with >50% of patients referred in the third trimester not completing sleep apnea testing. Early screening and referral for sleep apnea evaluation in pregnancy should be prioritized, given the time-sensitive nature of diagnosis and therapy initiation, and demonstrated reduced completion of referrals in advanced pregnancy. Support (if any) None


2008 ◽  
Vol 9 (6) ◽  
pp. 660-666 ◽  
Author(s):  
Carlos J. Egea ◽  
Felipe Aizpuru ◽  
Jose A. Pinto ◽  
Jose M. Ayuela ◽  
Eugeni Ballester ◽  
...  

Author(s):  
Amee Revana ◽  
Jason Vecchio ◽  
Danielle Guffey ◽  
Charles G. Minard ◽  
Daniel G. Glaze

CHEST Journal ◽  
2015 ◽  
Vol 148 (6) ◽  
pp. 1382-1395 ◽  
Author(s):  
Hui-Leng Tan ◽  
Leila Kheirandish-Gozal ◽  
David Gozal

2018 ◽  
Vol 22 (4) ◽  
pp. 1179-1188 ◽  
Author(s):  
Matthew P. Light ◽  
Thalia N. Casimire ◽  
Catherine Chua ◽  
Viachaslau Koushyk ◽  
Omar E. Burschtin ◽  
...  

2019 ◽  
pp. 29-80
Author(s):  
Nancy Foldvary-Schaefer ◽  
Madeleine Grigg-Damberger ◽  
Reena Mehra

This chapter provides an overview of sleep testing performed inside or outside the sleep laboratory. The chapter reviews the classification of sleep studies and methodology of in-lab polysomnography and home sleep apnea testing. Specifically, the indications for and relative contraindications and limitations of both procedures are discussed. Positive airway pressure (PAP) titration procedures are reviewed and the PAP-NAP, an abbreviated daytime study for patients with sleep apnea and PAP intolerance or hesitancy, is described. The authors also discuss the methodology of, indications for, and interpretation of the multiple sleep latency test and the maintenance of wakefulness test, which are daytime studies performed to evaluate excessive daytime sleepiness. Finally, the role of actigraphy in the evaluation of sleep disorders is discussed.