Structure and Properties of Alkaline Cement and Concrete and Choice of Factors That Affect Service Life

2021 ◽  
Author(s):  
Oles Lastivka

The chapter covers the results of influence of changes in proportions between Portland cement and slag content, along with different quantities of alkali components in the cement systems on their heat of hydration and the effect of this during their hardening on character of internal stresses development and crack opening in concrete. The correlation between heat of hydration of the cements during hardening, strength of the concrete and stress development, and the dependence of this relationship on technical and technological factors were received. A new structure-based model for the durability (cracking) assessment of the alkaline cement concrete with heat of hydration and deformation properties during hardening as the input was received.

1997 ◽  
Vol 503 ◽  
Author(s):  
B. K. Diefenderfer ◽  
I. L. Al-Qadi ◽  
J. J. Yoho ◽  
S. M. Riad ◽  
A. Loulizi

ABSTRACTPortland cement concrete (PCC) structures deteriorate with age and need to be maintained or replaced. Early detection of deterioration in PCC (e.g., alkali-silica reaction, freeze/thaw damage, or chloride presence) can lead to significant reductions in maintenance costs. However, it is often too late to perform low-cost preventative maintenance by the time deterioration becomes evident. By developing techniques that would enable civil engineers to evaluate PCC structures and detect deterioration at early stages (without causing further damage), optimization of life-cycle costs of the constructed facility and minimization of disturbance to the facility users can be achieved.Nondestructive evaluation (NDE) methods are potentially one of the most useful techniques ever developed for assessing constructed facilities. They are noninvasive and can be performed rapidly. Portland cement concrete can be nondestructively evaluated by electrically characterizing its complex dielectric constant. The real part of the dielectric constant depicts the velocity of electromagnetic waves in PCC. The imaginary part, termed the “loss factor,” describes the conductivity of PCC and the attenuation of electromagnetic waves.Dielectric properties of PCC have been investigated in a laboratory setting using a parallel plate capacitor operating in the frequency range of 0.1 to 40.1MIHz. This capacitor set-up consists of two horizontal-parallel plates with an adjustable separation for insertion of a dielectric specimen (PCC). While useful in research, this approach is not practical for field implementation. A new capacitor probe has been developed which consists of two plates, located within the same horizontal plane, for placement upon the specimen to be tested. Preliminary results show that this technique is feasible and results are promising; further testing and evaluation is currently underway.


2008 ◽  
Vol 38 (6) ◽  
pp. 832-840 ◽  
Author(s):  
David G. Snelson ◽  
Stan Wild ◽  
Martin O'Farrell

Sign in / Sign up

Export Citation Format

Share Document