scholarly journals Variation in Use of High-Cost Technologies for Palliative Radiation Therapy by Radiation Oncologists

2021 ◽  
Vol 19 (4) ◽  
pp. 421-431
Author(s):  
Aileen B. Chen ◽  
Jiangong Niu ◽  
Angel M. Cronin ◽  
Ya-Chen Tina Shih ◽  
Sharon Giordano ◽  
...  

Background: Understanding the sources of variation in the use of high-cost technologies is important for developing effective strategies to control costs of care. Palliative radiation therapy (RT) is a discretionary treatment and its use may vary based on patient and clinician factors. Methods: Using data from the SEER-Medicare linked database, we identified patients diagnosed with metastatic lung, prostate, breast, and colorectal cancers in 2010 through 2015 who received RT, and the radiation oncologists who treated them. The costs of radiation services for each patient over a 90-day episode were calculated, and radiation oncologists were assigned to cost quintiles. The use of advanced technologies (eg, intensity-modulated radiation, stereotactic RT) and the number of RT treatments (eg, any site, bone only) were identified. Multivariable random-effects models were constructed to estimate the proportion of variation in the use of advanced technologies and extended fractionation (>10 fractions) that could be explained by patient fixed effects versus physician random effects. Results: We identified 37,361 patients with metastatic lung cancer, 3,684 with metastatic breast cancer, 5,323 with metastatic prostate cancer, and 8,726 with metastatic colorectal cancer, with 34%, 27%, 22%, and 9% receiving RT within the first year, respectively. The use of advanced technologies and extended fractionation was associated with higher costs of care. Compared with the patient case-mix, physician variation accounted for a larger proportion of the variation in the use of advanced technologies for palliative RT and the use of extended fractionation. Conclusions: Differences in radiation oncologists’ practice and choices, rather than differences in patient case-mix, accounted for a greater proportion of the variation in the use of advanced technologies and high-cost radiation services.

2020 ◽  
Vol 8 (2) ◽  
pp. e001095 ◽  
Author(s):  
Lillian Siu ◽  
Joshua Brody ◽  
Shilpa Gupta ◽  
Aurélien Marabelle ◽  
Antonio Jimeno ◽  
...  

BackgroundMEDI9197 is an intratumorally administered toll-like receptor 7 and 8 agonist. In mice, MEDI9197 modulated antitumor immune responses, inhibited tumor growth and increased survival. This first-time-in-human, phase 1 study evaluated MEDI9197 with or without the programmed cell death ligand-1 (PD-L1) inhibitor durvalumab and/or palliative radiation therapy (RT) for advanced solid tumors.Patients and methodsEligible patients had at least one cutaneous, subcutaneous, or deep-seated lesion suitable for intratumoral (IT) injection. Dose escalation used a standard 3+3 design. Patients received IT MEDI9197 0.005–0.055 mg with or without RT (part 1), or IT MEDI9197 0.005 or 0.012 mg plus durvalumab 1500 mg intravenous with or without RT (part 3), in 4-week cycles. Primary endpoints were safety and tolerability. Secondary endpoints included pharmacokinetics, pharmacodynamics, and objective response based on Response Evaluation Criteria for Solid Tumors version 1.1. Exploratory endpoints included tumor and peripheral biomarkers that correlate with biological activity or predict response.ResultsFrom November 2015 to March 2018, part 1 enrolled 35 patients and part 3 enrolled 17 patients; five in part 1 and 2 in part 3 received RT. The maximum tolerated dose of MEDI9197 monotherapy was 0.037 mg, with dose-limiting toxicity (DLT) of cytokine release syndrome in two patients (one grade 3, one grade 4) and 0.012 mg in combination with durvalumab 1500 mg with DLT of MEDI9197-related hemorrhagic shock in one patient (grade 5) following liver metastasis rupture after two cycles of MEDI9197. Across parts 1 and 3, the most frequent MEDI9197-related adverse events (AEs) of any grade were fever (56%), fatigue (31%), and nausea (21%). The most frequent MEDI9197-related grade ≥3 events were decreased lymphocytes (15%), neutrophils (10%), and white cell counts (10%). MEDI9197 increased tumoral CD8+ and PD-L1+ cells, inducing type 1 and 2 interferons and Th1 response. There were no objective clinical responses; 10 patients in part 1 and 3 patients in part 3 had stable disease ≥8 weeks.ConclusionIT MEDI9197 was feasible for subcutaneous/cutaneous lesions but AEs precluded its use in deep-seated lesions. Although no patients responded, MEDI9197 induced systemic and intratumoral immune activation, indicating potential value in combination regimens in other patient populations.Trial registration numberNCT02556463.


Author(s):  
Nicholas G. Zaorsky ◽  
Menglu Liang ◽  
Rutu Patel ◽  
Christine Lin ◽  
Leila T. Tchelebi ◽  
...  

2018 ◽  
Vol 102 (2) ◽  
pp. 320-324 ◽  
Author(s):  
Audrey S. Wallace ◽  
John B. Fiveash ◽  
Courtney P. Williams ◽  
Elizabeth Kvale ◽  
Maria Pisu ◽  
...  

2016 ◽  
Vol 119 ◽  
pp. S670
Author(s):  
L. Caravatta ◽  
G. Torre ◽  
F. Deodato ◽  
J. Capuccini ◽  
A. Farioli ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document