scholarly journals The Cross-calibration for Plane-parallel Chambers in Electron Beams

2004 ◽  
Vol 60 (10) ◽  
pp. 1389-1404
Author(s):  
HIROSHI OGUCHI
2021 ◽  
Vol 27 (4) ◽  
pp. 303-313
Author(s):  
Kinga Polaczek-Grelik ◽  
Aneta Kawa-Iwanicka ◽  
Łukasz Michalecki

Abstract Introduction: The accuracy of the cross-calibration procedure depends on ionization chamber type, both used as reference one and under consideration. Also, the beam energy and phantom medium could influence the precision of cross calibration coefficient, resulting in a systematic error in dose estimation and thus could influence the linac beam output checking. This will result in a systematic mismatch between dose calculated in treatment planning system and delivered to the patient. Material and methods: The usage of FC65-G, CC13 and CC01 thimble reference chambers as well as 6, 9, and 15 MeV electron beams has been analyzed. A plane-parallel PPC05 chamber was calibrated since scarce literature data are available for this dosimeter type. The influence of measurement medium and an effective point of measurement (EPOM) on obtained results are also presented. Results: Dose reconstruction precision of ~0.1% for PPC05 chamber could be obtained when cross-calibration is based on a thimble CC13 chamber. Nd,w,Qcross obtained in beam ≥ 9MeV gives 0.1 – 0.5% precision of dose reconstruction. Without beam quality correction, 15 MeV Nd,w,Qcross is 10% lower than Co-60 Nd,w,0. Various EPOM shifts resulted in up to 0.6% discrepancies in Nd,w,Qcross values. Conclusions: Ionization chamber with small active volume and tissue-equivalent materials supplies more accurate cross-calibration coefficients in the range of 6 – 15 MeV electron beams. In the case of 6 and 9 MeV beams, the exact position of an effective point of measurement is of minor importance. In-water cross-calibration coefficient can be used in a solid medium without loss of dose accuracy.


Author(s):  
Tamotsu Ohno

The energy distribution in an electron; beam from an electron gun provided with a biased Wehnelt cylinder was measured by a retarding potential analyser. All the measurements were carried out with a beam of small angular divergence (<3xl0-4 rad) to eliminate the apparent increase of energy width as pointed out by Ichinokawa.The cross section of the beam from a gun with a tungsten hairpin cathode varies as shown in Fig.1a with the bias voltage Vg. The central part of the beam was analysed. An example of the integral curve as well as the energy spectrum is shown in Fig.2. The integral width of the spectrum ΔEi varies with Vg as shown in Fig.1b The width ΔEi is smaller than the Maxwellian width near the cut-off. As |Vg| is decreased, ΔEi increases beyond the Maxwellian width, reaches a maximum and then decreases. Note that the cross section of the beam enlarges with decreasing |Vg|.


1997 ◽  
Vol 119 (2) ◽  
pp. 236-242 ◽  
Author(s):  
K. Peleg

The classical calibration problem is primarily concerned with comparing an approximate measurement method with a very precise one. Frequently, both measurement methods are very noisy, so we cannot regard either method as giving the true value of the quantity being measured. Sometimes, it is desired to replace a destructive or slow measurement method, by a noninvasive, faster or less expensive one. The simplest solution is to cross calibrate one measurement method in terms of the other. The common practice is to use regression models, as cross calibration formulas. However, such models do not attempt to discriminate between the clutter and the true functional relationship between the cross calibrated measurement methods. A new approach is proposed, based on minimizing the sum of squares of the differences between the absolute values of the Fast Fourier Transform (FFT) series, derived from the readings of the cross calibrated measurement methods. The line taken is illustrated by cross calibration examples of simulated linear and nonlinear measurement systems, with various levels of additive noise, wherein the new method is compared to the classical regression techniques. It is shown, that the new method can discover better the true functional relationship between two measurement systems, which is occluded by the noise.


1995 ◽  
Vol 22 (8) ◽  
pp. 1307-1314 ◽  
Author(s):  
P. R. Almond ◽  
Zhigang Xu ◽  
Hui Li ◽  
H. C. Park

2020 ◽  
Vol 12 (18) ◽  
pp. 3105
Author(s):  
Nicolas Lamquin ◽  
Ludovic Bourg ◽  
Sébastien Clerc ◽  
Craig Donlon

This study is a follow-up of a full methodology for the homogenisation and harmonisation of the two Ocean and Land Colour Instrument (OLCI) payloads based on the OLCI-A/OLCI-B tandem phase analysis. This analysis provided cross-calibration factors between the two instruments with a very high precision, providing a ‘truth’ from the direct comparison of simultaneous and collocated acquisitions. The long-term monitoring of such cross-calibration is a prerequisite for an operational application of sensors harmonisation along the mission lifetime, no other tandem phase between OLCI-A and OLCI-B being foreseen due to the cost of such operation. This article presents a novel approach for the monitoring of the OLCI radiometry based on statistics of Deep Convective Clouds (DCC) observations, especially dedicated to accurately monitor the full across-track dependency of the cross-calibration of OLCI-A and OLCI-B. Specifically, the inflexion point of DCC reflectance distributions is used as an indicator of the absolute calibration for each subdivision of the OLCI Field-of-View. This inflexion point is shown to provide better precision than the mode of the distributions which is commonly used in the community. Excess of saturation in OLCI-A high radiances is handled through the analysis of interband relationships between impacted channels and reference channels that are not impacted by saturation. Such analysis also provides efficient insights on the variability of the target’s response as well as on the evolution of the interband calibration of each payload. First, cross-calibration factors obtained over the tandem period allows to develop and validate the approach, notably for the handling of the saturated pixels, based on the comparison with the ‘truth’ obtained from the tandem analysis. Factors obtained out of (and far from) the tandem period then provides evidence that the cross-calibration reported over the tandem period (1–2% bias between the instruments) as well as inter-camera calibration residuals persist with very similar proportions, to the exception of the 400 nm channel and with slightly less precision for the 1020 nm channel. For all OLCI channels, relative differences between the cross-calibration factors obtained from the tandem analysis and the factors obtained over the other period are below 1% from a monthly analysis, even below 0.5% from a multi-monthly analysis). This opens the way not only to an accurate long-term monitoring of the OLCI radiometry but also, and precisely targeted for this study, to the monitoring of the cross-calibration of the two sensors over the mission lifetime. It also provides complementary information to the tandem analysis as the calibration indicators are traced individually for each sensor across-track, confirming and quantifying inter-camera radiometric biases, independently for both sensors. Assumptions used in this study are discussed and validated, also providing a framework for the adaptation of the presented methodology to other optical sensors.


1994 ◽  
Vol 19 (2) ◽  
pp. 73-76 ◽  
Author(s):  
Claudio Fiorino ◽  
Giovanni Mauro Cattaneo ◽  
Antonella Del Vecchio ◽  
Marcello Fusca ◽  
Barbara Longobardi ◽  
...  

2002 ◽  
Vol 47 (9) ◽  
pp. N121-N126 ◽  
Author(s):  
G Christ ◽  
O S Dohm ◽  
G Bruggmoser ◽  
E Sch$uuml$le