scholarly journals Comparison of Mixed H 2 /H∞ with Regional Pole Placement Control and H 2 Optimal Control for the Design of Steam Condenser

2020 ◽  
2021 ◽  
pp. 107754632110429
Author(s):  
Pouriya Pourgholam ◽  
Hamid Moeenfard

Accurate modeling and efficient control of inverted pendulums have always been a challenge for researchers. So, the current research aims to achieve the following objectives: (I) proposing a comprehensive dynamic model for the inverted pendulums which accounts for the flexibility of the pendulum bar and (II) suggesting an appropriate supervisory fuzzy-pole placement control strategy for stabilizing the pendulum system. Using a Lagrangian formulation, the equations of motion are derived and linearized. Then, a state feedback controller with a reduced-order observer is designed to stabilize the system. Closed-loop simulations reveal that at least six modes shall be considered in the dynamic equations. To improve the quality of the transient response, a novel fuzzy system is developed for real-time assignment of the controller poles. Simulation results demonstrate that the control quality is significantly improved by adding a supervisory fuzzy system to the control loop. The developed approach for dynamic modeling of the system, and the idea of multi-level fuzzy-pole placement control architecture developed in this paper, may be successfully applied to improve the response specifications in other dynamic systems.


2021 ◽  
Vol 20 (2) ◽  
pp. 25-32
Author(s):  
Noorhazirah Sunar ◽  
Mohd Fua’ad Rahmat ◽  
Ahmad ‘Athif Mohd Fauzi ◽  
Zool Hilmi Ismail ◽  
Siti Marhanis Osman ◽  
...  

Dead-zone in the valve degraded the performances of the Electro-Pneumatic Actuator (EPA) system.  It makes the system difficult to control, become unstable and leads to chattering effect nearest desired position.  In order to cater this issue, the EPA system transfer function and the dead-zone model is identified by MATLAB SI toolbox and the Particle Swarm Optimization (PSO) algorithm respectively.  Then a parametric control is designed based on pole-placement approach and combine with feed-forward inverse dead-zone compensation.  To reduce chattering effect, a smooth parameter is added to the controller output.  The advantages of using these techniques are the chattering effect and the dead-zone of the EPA system is reduced.  Moreover, the feed-forward system improves the transient performance.  The results are compared with the pole-placement control (1) without compensator and (2) with conventional dead-zone compensator.  Based on the experimental results, the proposed controller reduced the chattering effect due to the controller output of conventional dead-zone compensation, 90% of the pole-placement controller steady-state error and 30% and 40% of the pole-placement controller with conventional dead-zone compensation settling time and rise time.


Sign in / Sign up

Export Citation Format

Share Document