scholarly journals Surgical Treatment of Type 31-A1 Two-part Intertrochanteric Femur Fractures: Is Proximal Femoral Nail Superior to Dynamic Hip Screw Fixation?

Cureus ◽  
2019 ◽  
Author(s):  
Hariharan Mohan ◽  
Prakash Kumar
Author(s):  
Dr Prafulla Herode ◽  
◽  
Dr Abhijeet Shroff ◽  
Dr Mohan Sadaria ◽  
Dr Patel Jeegar Mohan ◽  
...  

Author(s):  
Anderson Freitas ◽  
Landwehrle de Lucena da Silva ◽  
Renilton Rodrigues Costa ◽  
Lucas Sacramento Ramos ◽  
Marcos Norberto Giordano ◽  
...  

Resumo Objetivo Identificar a energia necessária para ocorrência de fratura do fêmur proximal em osso sintético após retirada de três modelos de implantes: parafusos canulados, parafuso dinâmico do quadril (dynamic hip screw-DHS) e haste femoral proximal (proximal femoral nail-PFN). Métodos Foram utilizados 25 modelos de ossos sintéticos da extremidade proximal do fêmur: 10 unidades de grupo controle (GC), 5 unidades após colocação e retirada de 3 parafusos canulados colocados em configuração de triângulo invertido (GPC), 5 unidades após colocação e retirada do parafuso de compressão dinâmico (GDHS), e 5 unidades após colocação e retirada da haste de fêmur proximal (GPFN). Uma análise biomecânica foi realizada em todas as amostras simulando uma queda sobre o grande trocânter utilizando uma máquina servo-hidráulica com o objetivo de verificar a energia (em Joules [J]) necessária até a ocorrência de fratura nos diferentes grupos. Resultados Todos os grupos apresentaram fratura basocervical. Os grupos GC, GPC, GDHS e GPFN apresentaram, respectivamente, valores de 7.1J, 6.6J, 6J e 6.7J de energia até ocorrência da fratura. Não houve diferença estatisticamente significativa (intervalo de confiança de 95%) na energia entre os grupos de estudo (p = 0,34). Conclusão Não houve diferença estatisticamente significativa nos valores de energia necessária para ocorrência de fratura da extremidade proximal do fêmur após a retirada de três tipos de implantes utilizando modelos sintéticos simulando queda sobre o grande trocânter.


Author(s):  
E. S. Radhe Shyam ◽  
K. Ashwin

<p class="abstract"><strong>Background:</strong> The incidence of inter trochanteric fracture is expected to have doubled by 2040. Inter trochanteric fractures account for about 45% to 50% of all hip fractures in the elderly populationand out of these, near about 50% to 60% are classified as unstable intertrochanteric fractures. The goal of treatment is restoring mobility safely and efficiently, while minimizing the risk of medical complications and technical failure. This study as performed<strong> </strong>to assess functional outcome with dynamic hip screw and proximal femoral nail in intertrochanteric fracture management.</p><p class="abstract"><strong>Methods:</strong> It was prospective observational study done for a period of 1year from January 2016-January 2017 among patients who attended OPD or emergency department with intertrochanteric fracture. Two different implants were used dynamic hip screw (DHS) and proximal femoral nail (PFN).<strong></strong></p><p class="abstract"><strong>Results:</strong> Excellent results in functional outcome was more in case of PFN (66.6%) compared to DHS (50%). The type of trauma in DHS group was road traffic accident in 38.8%, domestic fall in 50% and others such as assault was in 11.1% while in PFN group intertrochanteric fracture was seen in 61.1% due to domestic fall.</p><p class="abstract"><strong>Conclusions:</strong> The functional outcome was more better with proximal femoral nail (PFN) compared to dynamic hip screw (DHS). Therefore, proximal femoral nail (PFN) should be preferred for management of intertrochanteric fractures.</p>


Sign in / Sign up

Export Citation Format

Share Document