respiration monitoring
Recently Published Documents


TOTAL DOCUMENTS

255
(FIVE YEARS 102)

H-INDEX

21
(FIVE YEARS 7)

2022 ◽  
Author(s):  
Neel Patel ◽  
Rahul Gupta ◽  
Anas Ali

2022 ◽  
pp. 79-97
Author(s):  
Wenjin Wang ◽  
Albertus C. den Brinker

Author(s):  
Bruno Madore ◽  
Gabriela Belsley ◽  
Cheng-Chieh Cheng ◽  
Frank Preiswerk ◽  
Marie Foley Kijewski ◽  
...  

Abstract Breathing motion can displace internal organs by up to several cm; as such, it is a primary factor limiting image quality in medical imaging. Motion can also complicate matters when trying to fuse images from different modalities, acquired at different locations and/or on different days. Currently available devices for monitoring breathing motion often do so indirectly, by detecting changes in the outline of the torso rather than the internal motion itself, and these devices are often fixed to floors, ceilings or walls, and thus cannot accompany patients from one location to another. We have developed small ultrasound-based sensors, referred to as ‘organ configuration motion’ (OCM) sensors, that attach to the skin and provide rich motion-sensitive information. In the present work we tested the ability of OCM sensors to enable respiratory gating during in vivo PET imaging. A motion phantom involving an FDG solution was assembled, and two cancer patients scheduled for a clinical PET/CT exam were recruited for this study. OCM signals were used to help reconstruct phantom and in vivo data into time series of motion-resolved images. As expected, the motion-resolved images captured the underlying motion. In Patient #1, a single large lesion proved to be mostly stationary through the breathing cycle. However, in Patient #2, several small lesions were mobile during breathing, and our proposed new approach captured their breathing-related displacements. In summary, a relatively inexpensive hardware solution was developed here for respiration monitoring. Because the proposed sensors attach to the skin, as opposed to walls or ceilings, they can accompany patients from one procedure to the next, potentially allowing data gathered in different places and at different times to be combined and compared in ways that account for breathing motion.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Hee Yong Kang ◽  
Ann Hee You ◽  
Youngsoon Kim ◽  
You Jeong Jeong ◽  
Geuk Young Jang ◽  
...  

AbstractThe importance of perioperative respiration monitoring is highlighted by high incidences of postoperative respiratory complications unrelated to the original disease. The objectives of this pilot study were to (1) simultaneously acquire respiration rate (RR), tidal volume (TV), minute ventilation (MV), SpO2 and PetCO2 from patients in post-anesthesia care unit (PACU) and (2) identify a practical continuous respiration monitoring method by analyzing the acquired data in terms of their ability and reliability in assessing a patient’s respiratory status. Thirteen non-intubated patients completed this observational study. A portable electrical impedance tomography (EIT) device was used to acquire RREIT, TV and MV, while PetCO2, RRCap and SpO2 were measured by a Capnostream35. Hypoventilation and respiratory events, e.g., apnea and hypopnea, could be detected reliably using RREIT, TV and MV. PetCO2 and SpO2 provided the gas exchange information, but were unable to detect hypoventilation in a timely fashion. Although SpO2 was stable, the sidestream capnography using the oronasal cannula was often unstable and produced fluctuating PetCO2 values. The coefficient of determination (R2) value between RREIT and RRCap was 0.65 with a percentage error of 52.5%. Based on our results, we identified RR, TV, MV and SpO2 as a set of respiratory parameters for robust continuous respiration monitoring of non-intubated patients. Such a respiration monitor with both ventilation and gas exchange parameters would be reliable and could be useful not only for respiration monitoring, but in making PACU discharge decisions and adjusting opioid dosage on general hospital floor. Future studies are needed to evaluate the potential clinical utility of such an integrated respiration monitor.


2021 ◽  
Vol 194 ◽  
pp. 113609
Author(s):  
Jieyu Dai ◽  
Linlin Li ◽  
Bojing Shi ◽  
Zhou Li

2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Xiaoyi Wang ◽  
Yang Deng ◽  
Xingru Chen ◽  
Peng Jiang ◽  
Yik Kin Cheung ◽  
...  

AbstractThe humidity sensor is an essential sensing node in medical diagnosis and industrial processing control. To date, most of the reported relative humidity sensors have a long response time of several seconds or even hundreds of seconds, which would limit their real application for certain critical areas with fast-varying signals. In this paper, we propose a flexible and low-cost humidity sensor using vertically aligned carbon nanotubes (VACNTs) as electrodes, a PDMS-Parylene C double layer as the flexible substrate, and graphene oxide as the sensing material. The humidity sensor has an ultrafast response of ~20 ms, which is more than two orders faster than most of the previously reported flexible humidity sensors. Moreover, the sensor has a high sensitivity (16.7 pF/% RH), low hysteresis (<0.44%), high repeatability (2.7%), good long-term stability, and outstanding flexibility. Benefiting from these advantages, especially the fast response, the device has been demonstrated in precise human respiration monitoring (fast breathing, normal breathing, deep breathing, asthma, choking, and apnea), noncontact electrical safety warning for bare hand and wet gloves, and noncontact pipe leakage detection. In addition, the facile fabrication of the flexible platform with the PDMS-Parylene C double layer can be easily integrated with multisensing functions such as pH sensing, ammonium ion sensing, and temperature sensing, all of which are useful for more pattern recognition of human activity.


ACS Omega ◽  
2021 ◽  
Author(s):  
Linden K. Allison ◽  
Soha Rostaminia ◽  
Ali Kiaghadi ◽  
Deepak Ganesan ◽  
Trisha L. Andrew

Author(s):  
Nishith Shivakumar Shagle ◽  
Thanh Nguyen ◽  
Trung-Hieu Vu ◽  
Hung Nguyen ◽  
Hoang-Phuong Phan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document