2013 ◽  
Vol 347-350 ◽  
pp. 1945-1948
Author(s):  
Jian Xu ◽  
Xin Yao

Fourier algorithm can be effective utilized in the Microcomputer relay protection to filter out Harmonic component in the AC signal .but the drawback is that not filter attenuation DC component. it may be affect the computation accuracy of the entire system .and it is also reduce the efficiency of the system. In this paper ,we combined with the actual project ,on the basis of analysis of the full-wave Fourier algorithm ,for the problem of it can not filter decaying a periodic component ,we proposed an improved algorithm, and combined with MATLAB simulation ,the results show that the improved algorithm has the advantages of high accuracy and the algorithm is simple. In the microcomputer relay protection of the power system need to handle all kinds of signals, provide the necessary information for the implementation of protection. however, With the rapid development of computer technology and the continuous research of computer algorithms, a lot of actual power system protection device has been widely used in our life, on the one hand, these devices reduce the complexity of building hardware circuit, on the other hand ,it can make full use of the filter function about some algorithms have itself. The most important is that it can avoid the problem of instability and low efficiency with some filter circuit. But, this characteristic need the algorithms has a high precision [2,3]. The algorithm is set up in the microcomputer protection is a mathematical model for achieve some specific function. and write the corresponding computer applications according to this model. Then do some specific mathematical operations with these digital signals will achieve the purpose of protection. At present, the widely used full wave Fourier algorithm has a function of filtering DC component and harmonic component[4],but it can not filtering the decaying DC component in the system. It will be cause a certain interference and influence to the whole system in the practical application, the result is that led to the precision of the operation drop and lose the meaning of the protecting. In this paper, combined with specific engineering example give an improved calculation method. Through example of simulation has proved that using this algorithm can accurately figure out fundamental component and harmonic component, and it has the advantage of algorithm simple and high accuracy [5].


2013 ◽  
Vol 706-708 ◽  
pp. 814-817
Author(s):  
Li Xia Zuo ◽  
Rong Guang Di

In order to ensure electrical railway’s safe and stable operation, a kind of microcomputer feeder protection device based on a double "ARM+DSP" CPU framework is designed. The hardware design can not only Improve protection performance, but also realize IEC61850 communication protocol. According to electromagnetic compatibility and anti-interference requirements, the whole hardware circuit is designed in detail, the debugging effect is good and can fully meet the demand of the system.


2011 ◽  
Vol 204-210 ◽  
pp. 1346-1350
Author(s):  
Wei Kang ◽  
Xing Chen ◽  
Jian Ting Gui ◽  
He Zhang ◽  
Li Xia Zhang

This paper established a 500kV microcomputer protection model with EFT/B generator. The generator was built based on the mechanism of arc forming and distinguishing when cutting off the no-load transmission line. The according parameters were set by the arc estimating formula and test data. The simulations shows that the traditional disincentive measure is limited for high voltage line and the arithmetic is still sensitive to the disturbance and made the relay set false operation. A comprehensive measure is put forward and tested by the microcomputer protection arithmetic.