multilayer stent
Recently Published Documents


TOTAL DOCUMENTS

43
(FIVE YEARS 4)

H-INDEX

11
(FIVE YEARS 1)

2020 ◽  
Vol 36 (4) ◽  
pp. 266-267
Author(s):  
Daniele Bissacco ◽  
Fabio Massimo Calliari ◽  
Marco Piercarlo Viani

2019 ◽  
Vol 61 ◽  
pp. 471.e17-471.e21
Author(s):  
Uei Pua ◽  
Glenn Wei Leong Tan ◽  
Ralf R. Kolvenbach ◽  
Lawrence Han Hwee Quek

2019 ◽  
Vol 59 ◽  
pp. 237-243
Author(s):  
Xiufeng Jin ◽  
Shangdong Xu ◽  
Zengsheng Chen ◽  
Xiwen Zhang ◽  
Lianjun Huang ◽  
...  

2019 ◽  
Vol 54 ◽  
pp. 290-297 ◽  
Author(s):  
Zhongyou Li ◽  
Fei Yan ◽  
Jingru Yang ◽  
Yu Chen ◽  
Zhizhi Xu ◽  
...  

2018 ◽  
Vol 28 (4) ◽  
pp. 655-656 ◽  
Author(s):  
Myriam Johanna Schafigh ◽  
Zaki Kohistani ◽  
Wolfgang Schiller ◽  
Chris Probst

2016 ◽  
Vol 15 (S2) ◽  
Author(s):  
Yan Xiong ◽  
Xuhong Wang ◽  
Wentao Jiang ◽  
Xiaobao Tian ◽  
Qingyuan Wang ◽  
...  
Keyword(s):  

Author(s):  
Juan S. Stockle ◽  
David A. Romero ◽  
Cristina H. Amon

Multilayer stents or flow modulators are novel devices used for endovascular repair of abdominal aortic aneurysms (AAAs) in patients with unsuitable or complex endovascular geometries. The use of this device is still controversial due to insufficient patient follow-up data and the lack of CFD studies addressing the problem. In this work, we present a methodology to design the flow resistance characteristics needed from multilayer stents to induce suitable hemodynamic conditions inside the aneurysm sac. A hypothetical AAA geometry with and without the device is employed to study the impact on hemodynamic factors of interest such as: the shear stress and pressure distribution on the aneurysm wall, their maximum and average values, and the flow fields inside the aneurysm sac. To model the stent, the porosity and the flow resistance values are used to scale the mass and the Naviers’Stokes equations, including the contribution of the flow resistance on the momentum source term. Through a sensitivity study, the magnitude of the porosity is systematically varied to find the resistance profile that promotes suitable hemodynamic conditions inside the AAA, consistent with the goal of promoting intraluminal thrombus formation. Our results have important implications for designing the layer structures of the multilayer stent to reduce the risks of aneurysm rupture.


2016 ◽  
Vol 67 (16) ◽  
pp. S309-S311
Author(s):  
Jong Hyun Choi ◽  
Han Cheol Lee ◽  
Jin Sup Park ◽  
Hye Won Lee ◽  
Jun-Hyok Oh ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document