Microfiltration and ultrafiltration for water/wastewater treatment have gained global attention due to their high separation efficiency, while membrane fouling still remains one of their bottlenecks. In such a situation, many researchers attempt to obtain a deep understanding of fouling mechanisms and to develop effective fouling controls. Therefore, this article intends to trigger discussions on the appropriate choice of foulant surrogates and the application of mathematic models to analyze fouling mechanisms in these filtration processes. It has been found that the commonly used foulant surrogate (sodium alginate) cannot ideally represent the organic foulants in practical feed water to explore the fouling mechanisms. More surrogate foulants or extracellular polymeric substance (EPS) extracted from practical source water may be more suitable for use in the studies of membrane fouling problems. On the other hand, the support vector machine (SVM) which focuses on the general trends of filtration data may work as a more powerful simulation tool than traditional empirical models to predict complex filtration behaviors. Careful selection of foulant surrogate substances and the application of accurate mathematical modeling for fouling mechanisms would provide deep insights into the fouling problems.


2015 ◽  
Vol 40 (2) ◽  
pp. 113-119 ◽  
Author(s):  
Fredrik Uhlin ◽  
Jana Holmar ◽  
Pia Yngman-Uhlin ◽  
Anders Fernström ◽  
Ivo Fridolin

Background: Currently, urea reduction seems to be the most widely used dialysis dose parameter. The aim of this study was to investigate the possibility to monitor beta 2-microglobulin (β2-M) elimination by utilizing the ultraviolet (UV) absorbance of spent dialysate. Methods: Blood and spent dialysate were collected during two week's sessions in 8 patients, one week in hemodialysis (HD) and one in hemodiafiltration (HDF). Correlation analysis between UV-wavelengths and concentrations of solutes in spent dialysate was performed. The reduction ratio (RR) of concentrations in blood, dialysate and UV-absorbance were compared. Results: Differences between HD and HDF were discovered in wavelength correlation maxima for the solutes. Relative error in RR (%) was larger (p < 0.05) for β2-M than for the other solutes. The most reasonable explanation is that β2-M does not absorb UV-radiation; instead, the absorbance of surrogate substances is measured. Conclusion: A high correlation between UV-absorbance and β2-M can be achieved for HDF but not for HD. Still, UV-absorbance could perhaps be used in solely HDF mode for estimation of β2-M removal.


Sign in / Sign up

Export Citation Format

Share Document