lateral flare
Recently Published Documents


TOTAL DOCUMENTS

10
(FIVE YEARS 0)

H-INDEX

7
(FIVE YEARS 0)

Author(s):  
Adam P. Breceda ◽  
Michael J. DeRogatis ◽  
Patrick Lee ◽  
Vincent J. Vigorita ◽  
Eli Bryk ◽  
...  


Author(s):  
Sally Arno ◽  
Neal Kinariwala ◽  
Richelle Takemoto ◽  
Daniel Hennessy ◽  
Nguyen Q. Nguyen ◽  
...  

The femoral stem of a traditional total hip arthroplasty is believed to be essential for fixation and stability. Stems achieve early stability in a non-physiological fashion by a combination of friction and circumferential displacement of bone, similar to that of a nail being impacted into a piece of wood. In contrast, the “Revelation” femoral prosthesis, produced by DJO Surgical Corporation, relies upon a proximal lateral expansion (“Lateral Flare” design concept) to achieve stability.



2009 ◽  
Vol 2009.22 (0) ◽  
pp. 780-781
Author(s):  
Sota YAMAMOTO ◽  
Taichi OKADA ◽  
Shinji SAITO ◽  
Yoichi NAKAMURA ◽  
Eiichi TANAKA ◽  
...  


2008 ◽  
Vol 9 (1) ◽  
Author(s):  
Tobias Renkawitz ◽  
Francesco S Santori ◽  
Joachim Grifka ◽  
Carlos Valverde ◽  
Michael M Morlock ◽  
...  






2002 ◽  
Vol 26 (3) ◽  
pp. 166-169 ◽  
Author(s):  
Alex Leali ◽  
Joseph Fetto ◽  
Harvey Insler ◽  
David Elfenbein


1999 ◽  
Vol 9 (2) ◽  
pp. 71-80 ◽  
Author(s):  
P.S. Walker ◽  
S.G. Culligan ◽  
J. Hua ◽  
S.K. Muirhead-Allwood ◽  
G. Bentley
Keyword(s):  


1995 ◽  
Vol 5 (2) ◽  
pp. 52-62 ◽  
Author(s):  
J. Hua ◽  
P.S. Walker ◽  
W. Muirhead-Allwood ◽  
G. Bentley ◽  
C.J. McCullough

The purpose of this paper is to examine whether the rationale for CAD-CAM Custom Hips is realised in clinical practice. Previous studies demonstrated that custom uncemented stems, with a close fit proximally and a sliding fit distally, produced stresses closer to normal than for other stem types, which should result in the preservation of proximal bone. Custom stems showed less micromotion, especially in torsional loading, and hence should demonstrate interface osseointegration. The hips are designed and manufactured using specially written software. The standard design includes proximal macro-grooves with HA coating, an anterior flare, a lateral flare, a collar, and a smooth distal stem for a sliding fit. Elective features are added such as proximal stem twist and neck retroversion in CDH, increased stem length to bypass defects, curvatures in AP and ML views, and distal cutting flutes when extra torsional stability is required. From 1989 to 1994, 411 cases were carried out, approximately one-third in each of the categories of OA, JCA/CDH, and revision. Studies were made of the available radiographs at yearly intervals, while DEXA scans were taken of the RNOHT patients pre-operatively, at 6 months and then yearly. There were four failures requiring revision, three of the early primary design without HA coating, and one a revision design. The radiographs in primary hips showed complete proximal bone-implant apposition in 81% of all cases. The DEXA scans showed that the mean bone mass after two years for all seven Gruen zones was greater than 90%. It was concluded that the CAD-CAM HA-coated Custom Hips showed bone and interface stability up to this time. The hip has played a useful role in providing the ideal stem for each particular case, which may result in an improvement of long-term results, compared with the use of off-the-shelf implants.



Sign in / Sign up

Export Citation Format

Share Document