loss modelling
Recently Published Documents


TOTAL DOCUMENTS

125
(FIVE YEARS 38)

H-INDEX

17
(FIVE YEARS 1)

2021 ◽  
Author(s):  
Zhiwei Li ◽  
Jie Cao ◽  
Liang Chang ◽  
Sheng Li ◽  
Jian Ruan

Author(s):  
Debdeep Sarkar ◽  
Yahia Antar

In this paper, we demonstrate the usefulness of MoM (Method-of-Moments) based methods in efficient path-loss modelling for SISO (single-input single-output) communication links assisted by IRS (Intelligent Reflecting Surfaces). Being a full-wave computational electromagnetic tool, MoM is better equipped compared to high-frequency asymptotic methods like PO (Physical Optics), to handle the crucial electromagnetic (EM) effects like: mutual coupling between IRS unit-cells or interactions with spherical wave-front in antenna near-field. Furthermore, in terms of computational speed, accuracy and reproducibility, the MoM-based MATLAB Antenna Toolbox is significantly advantageous to emulate IRS-assisted wireless channels, as compared to the in-house FDTD (finite-difference time-domain) techniques. We consider a SISO system of two half-wavelength dipoles, and use a rectangular array of circular loops loaded with lumped circuit components as IRS. The lumped circuit loading enables us to control the reactance of individual unit-cells, resulting in alteration of IRS reflection coefficient and consequent changes in channel characteristics. Using numerous numerical simulations, we highlight the impacts of various IRS-parameters like: electrical size and number of unit-cells, distance of IRS from the transmitter/receiver as well as mutual coupling, on the path-loss models (both sub-6 GHz and mm-wave).


Author(s):  
Meryeme Jamil ◽  
Myriam Dumont ◽  
Abdelkader Benabou ◽  
Stéphane Clenet ◽  
Jean-Claude Mipo

2021 ◽  
Author(s):  
Fabio Cacciotto ◽  
Mirko Sciortino ◽  
Danilo Termini ◽  
Mario Cacciato ◽  
Santi Agatino Rizzo ◽  
...  

2021 ◽  
Author(s):  
Michal Laskowski ◽  
Slawomir J. Ambroziak ◽  
Luis M. Correia ◽  
Krzysztof Swider

Author(s):  
M. E. Diago‐Mosquera ◽  
A. Aragón‐Zavala ◽  
C. Vargas‐Rosales
Keyword(s):  

2021 ◽  
Author(s):  
E Pardo ◽  
M Staines ◽  
Zhenan Jiang ◽  
N Glasson

Power transformers using a high temperature superconductor (HTS) ReBCO coated conductor and liquid nitrogen dielectric have many potential advantages over conventional transformers. The ac loss in the windings complicates the cryogenics and reduces the efficiency, and hence it needs to be predicted in its design, usually by numerical calculations. This article presents detailed modelling of superconducting transformers with Roebel cable in the low-voltage (LV) winding and a high-voltage (HV) winding with more than 1000 turns. First, we model a 1 MVA 11 kV/415 V 3-phase transformer. The Roebel cable solenoid forming the LV winding is also analyzed as a stand-alone coil. Agreement between calculations and experiments of the 1 MVA transformer supports the model validity for a larger tentative 40 MVA 110 kV/11 kV 3-phase transformer design. We found that the ac loss in each winding is much lower when it is inserted in the transformer than as a stand-alone coil. The ac loss in the 1 and 40 MVA transformers is dominated by the LV and HV windings, respectively. Finally, the ratio of total loss over rated power of the 40 MVA transformer is reduced below 40% of that of the 1 MVA transformer. In conclusion, the modelling tool in this work can reliably predict the ac loss in real power applications. This is the Accepted Manuscript version of an article accepted for publication in 'Superconductor Science and Technology'. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at https://doi.org/10.1088/0953-2048/28/11/114008.


2021 ◽  
Author(s):  
E Pardo ◽  
M Staines ◽  
Zhenan Jiang ◽  
N Glasson

Power transformers using a high temperature superconductor (HTS) ReBCO coated conductor and liquid nitrogen dielectric have many potential advantages over conventional transformers. The ac loss in the windings complicates the cryogenics and reduces the efficiency, and hence it needs to be predicted in its design, usually by numerical calculations. This article presents detailed modelling of superconducting transformers with Roebel cable in the low-voltage (LV) winding and a high-voltage (HV) winding with more than 1000 turns. First, we model a 1 MVA 11 kV/415 V 3-phase transformer. The Roebel cable solenoid forming the LV winding is also analyzed as a stand-alone coil. Agreement between calculations and experiments of the 1 MVA transformer supports the model validity for a larger tentative 40 MVA 110 kV/11 kV 3-phase transformer design. We found that the ac loss in each winding is much lower when it is inserted in the transformer than as a stand-alone coil. The ac loss in the 1 and 40 MVA transformers is dominated by the LV and HV windings, respectively. Finally, the ratio of total loss over rated power of the 40 MVA transformer is reduced below 40% of that of the 1 MVA transformer. In conclusion, the modelling tool in this work can reliably predict the ac loss in real power applications. This is the Accepted Manuscript version of an article accepted for publication in 'Superconductor Science and Technology'. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at https://doi.org/10.1088/0953-2048/28/11/114008.


Sign in / Sign up

Export Citation Format

Share Document