detector parameter
Recently Published Documents


TOTAL DOCUMENTS

6
(FIVE YEARS 0)

H-INDEX

3
(FIVE YEARS 0)

2016 ◽  
Vol 30 (25) ◽  
pp. 1650322
Author(s):  
X. H. Zheng ◽  
L. Qiu ◽  
P. Yue ◽  
G. Wang ◽  
D. W. Tang

By analyzing the relationship among the heat penetration depth, measurement frequency and detector characteristic parameters, a simple and practical [Formula: see text] slope comparative method has been proposed. The corresponding measurement system for measuring the thermal properties of fluids and powder materials was established and verified using several specimens with known thermophysical parameters, such as alcohol, distilled water, and air. Compared to the two-dimensional model, the data processing of the method is relatively simple and quick. Due to the elimination of errors introduced by the detector parameter measurement, the measurement accuracy of the method is higher than the conventional one-dimensional model. By using an appropriate frequency range, the new method is time saving and convenient for measuring the thermal conductivity of fluids and powders with low thermal conductivity. Based on the analysis, the effective thermal conductivity of nano-SiO2 powder is accurately determined.


2012 ◽  
Vol 433-440 ◽  
pp. 6417-6421
Author(s):  
Fu Yong Qu ◽  
Xiang Wei Meng

Because of nonparametric detectors’ ability of ensuring constant false alarm rate (CFAR) for a wide class of input noise distributions and engineering implementation simply, much efforts have been directed towards the study of nonparametric methods of signal detection. This paper deals with a comparative analysis of nonparametric detectors-GS, MW, Savage detector under K-distributed clutter in homogeneous and nonhomogeneous background caused by multiple targets and clutter edge. Some results of detection probability versus signal-to-clutter ratio (SCR) are presented in curves for different detector parameter values in homogeneous and multiple targets background. And the ability to control the false alarm probability for the three nonparametric detectors is presented in table. The simulation results show that S detector performs robustly in homogeneous background and clutter edge background, and can tolerate more interfering targets through increasing the number of reference cells and pulse sweeps. Therefore as a compromise solution, S detector with moderate parameters can be used in actual radar system.


2010 ◽  
Vol 7 (6) ◽  
pp. 1700-1702 ◽  
Author(s):  
Dongni Hu ◽  
Linjun Wang ◽  
Jiahua Min ◽  
Kaifeng Qin ◽  
Jijun Zhang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document