magnetic pulse compressor
Recently Published Documents


TOTAL DOCUMENTS

32
(FIVE YEARS 1)

H-INDEX

6
(FIVE YEARS 1)

2019 ◽  
Vol 34 (2) ◽  
pp. 1540-1547 ◽  
Author(s):  
Song Li ◽  
Jingming Gao ◽  
Hanwu Yang ◽  
Danni Zhu ◽  
Baoliang Qian ◽  
...  

2018 ◽  
Vol 46 (10) ◽  
pp. 3708-3712
Author(s):  
Jae-Ho Rhee ◽  
Se-Hoon Kim ◽  
Ji-Eun Baek ◽  
Kwang-Cheol Ko

2018 ◽  
Vol 46 (7) ◽  
pp. 2599-2604
Author(s):  
Jae-Ho Rhee ◽  
Young-Maan Cho ◽  
Ji-Eun Baek ◽  
Se-Hoon Kim ◽  
Chang-Jin Lee ◽  
...  

2017 ◽  
Vol 45 (12) ◽  
pp. 3252-3257 ◽  
Author(s):  
Jae-Ho Rhee ◽  
Young-Maan Cho ◽  
Se-Hoon Kim ◽  
Kwang-Cheol Ko

2015 ◽  
Vol 86 (8) ◽  
pp. 084705
Author(s):  
Song Li ◽  
Jing-Ming Gao ◽  
Han-Wu Yang ◽  
Bao-Liang Qian ◽  
Ze-Xin Li

2015 ◽  
Vol 33 (3) ◽  
pp. 511-518 ◽  
Author(s):  
Song Li ◽  
Jing-Ming Gao ◽  
Han-Wu Yang ◽  
Bao-Liang Qian

AbstractIn this paper, a new technical scheme of high-voltage, long-pulse generator, mostly based on solid-state power devices, including magnetic pulse compressor, Blumlein-type rolled strip pulse-forming line (RSPFL) and inductive voltage adder (IVA), is proposed and investigated numerically and experimentally. The generator has potential advantages of high average power level, high repetitive rate capability, long lifetime, and long pulse achievability, which meet the requirements of military and industrial application of the pulsed power technology. Specifically, a two-stage magnetic pulse compressor was set up with iron-based amorphous cores. Total compression ratio of the device is approximately 12 and the achieved voltage efficiency is up to 92%. Low impedance, long-duration Blumlein-type RSPFL was established with characteristic impendence and electrical length of 3 Ω and 100 ns, respectively. Mylar film was selected as the solid-state dielectric. Increased by a four-stage IVA, typical quasi-square pulse was obtained with peak current of 2.3 kA and duration over 200 ns. As the resistance of the dummy load was measured to be 60 Ω, the peak voltage was approximately 138 kV. Experiments show reasonable agreement with numerical analysis.


2014 ◽  
Vol 59 (7) ◽  
pp. 1072-1081 ◽  
Author(s):  
E. V. Grabovskii ◽  
V. P. Bakhtin ◽  
A. M. Zhitlukhin ◽  
V. F. Levashov ◽  
A. P. Lototskii ◽  
...  

2014 ◽  
Vol 85 (5) ◽  
pp. 053302 ◽  
Author(s):  
Jiajin Lin ◽  
Jiande Zhang ◽  
Jianhua Yang ◽  
Huibo Zhang ◽  
Yongfeng Qiu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document